Instructions for use Bioclear XL 40000

Carefully read the operating instructions before using this filter for the first 
time. It is important that you know both the safety regulations and the use 
of this filter. It should be noted that people who did not sit
into the operating instructions should not work with the filter.
As we continuously improve and develop our products, accessories etc. 
differ from the pictures on the packaging.

Symbols

 

 

Inlet from the pump to the filter

 

 

Outlet from the filter to the pond

 

 

Rewind the filter

Unpacking

If you see damage to the filter or accessories when unpacking, 
you should notify your dealer immediately.

Safety regulations

Never use the pressure filter if the cable, UV-C lamp or filter container is damaged. Never 
open the UV-C housing or its parts unless it is written in these operating instructions. 
Check that the type plate of the appliance corresponds to your local voltage. The pressure 
filter must always be connected across a ground fault circuit interrupter of max. 30 mA. 
Make sure that electrical outlets and contacts are always dry.
If you have any doubts or questions regarding the electrical connections, consult an 
authorized electrician.
Interventions intended to manipulate or change the filter's electronics pose a danger. 
If such interventions are made, all warranty is void.
Never lift or carry the filter in the power cord. Protect it from heat, oil and sharp edges. 
Position the cable so that it is not damaged.
The appliance must not be used by children or by others whose physical or mental 
knowledge is not sufficient to use the appliance.
The pressure filter must never be immersed in water.
Never use the pressure filter if there are people in the pond.
Pumps with a larger capacity than those recommended by the filter manufacturer must not 
be used. The filter MUST be cleaned regularly. It must never work with a water pressure 
higher than 0.2 Bar = 2 meters lifting height. A higher working pressure in the filter can 
cause O-rings to not hold tightly and consequential damage occurs such as. that the dam 
is emptied of water.
The maximum pressure capacity of the pump must not exceed 0.5 Bar (5 meters lifting 
height).
Only use hoses that are approved for a pressure of at least 0.2 Bar. The height difference 
between the filter cover and the highest point of the outlet hose may be a maximum of 1 m.
Check and, if necessary, clean the filter outlet to the dam regularly. The outlet must always 
be free so that the filter does not risk being exposed to a pressure higher than 0.2 Bar. This 
can cause the filter to start leaking and emptying the dust.
During all work on the pressure filter and the UV-C unit, the current must always be cut off 
by pulling the electrical plug out of the socket.

Technical data

Model: 40000
Filter volume:  

170 liter

Max. pond size without fish: 

40.000 liter

Max. pond size with little fish: 

20.000 liter

Max. pond size with lots of fish/koi:  10.000 liter
Max. pump capacity: 

15.000 l/t

Inlet / outlet: 

40/50 mm

UV HQ2 PL: 

55 watt

Volt: 

230V 50 Hz

Connection with external thread 

2”

Size (LxBxH): 

60x60x85 cm

English

The box contains

bioclear pressure filter with UV

3x2  hose connections 40/50 mm hose
2   unions
3   flat packs
1   drain tap with universal hose connection and union
1   instructions for use

Use

Bioclear with built-in UV-C is a biological and mechanical pressure filter intended for 
cleaning garden ponds with or without fish. It is for private use only.

Содержание Bioclear XL 40000

Страница 1: ...sure filter Bioclear XL 40000 Model 2019 Instructions for use IMPORTANT Please read this instruction manual carefully before using this product Keep the manual safe for future reference Manual version 7 9 2022 www pondteam com ...

Страница 2: ...t sufficient to use the appliance The pressure filter must never be immersed in water Never use the pressure filter if there are people in the pond Pumps with a larger capacity than those recommended by the filter manufacturer must not be used The filter MUST be cleaned regularly It must never work with a water pressure higher than 0 2 Bar 2 meters lifting height A higher working pressure in the f...

Страница 3: ...e water continues into the inner chamber of the filter D Biological cleaning The pores of the filter sponges create a large biological surface where the beneficial decomposing bacteria take root The yellow and blue filter sponges have different port densities It creates zones with different permeability and oxygen content for different kinds of bacteria Zones with a high permeability blue sponges ...

Страница 4: ... tear due to operation and weather conditions it needs to be maintained regularly to maintain its good function Over time sludge and dirt will block the filter sponges which must then be cleaned You notice that the pressure on the outlet decreases or cloudy water comes out of the filter It is a good idea to clean the filter sponges about every 14 days or if you notice that the flow decreases 1 Ope...

Страница 5: ...ason storage and maintenance Before putting the filter into operation for the spring lubricate all O rings with silicone grease The UV C lamp must be replaced once a year even if it is lit There may be plastic residue in the quartz glass these can only be thrown away These are parts of a plastic cover that have been worn up by the UV C rays The part fulfilled its purpose during the transport of th...

Страница 6: ... is approx 1 kg fish 1000 l water Feed sparingly The filter sponges are dirty Clean the filter sponges The quartz glass is dirty Remove the UV part and clean the quartz glass UV lamp does not light up Check that there is electricity in the socket Check that the earth leakage circuit breaker is in position P Defective or too old UV lamp Replace UV lamp Fault in the electrical connection Check the c...

Страница 7: ...ogues are the property of their respective owners We reserve the right to change specifi cations of products App s and recommendations without notice Some products are protected internationally by registered design and patents further patents pending Waste management A defect product must Not be thrown in the normal municipal waste but must be delivered at one of the home municipality s recycling ...

Страница 8: ...r mentala kunskaper inte är tillräckliga för att använda apparaten Tryckfiltret får aldrig nedsänkas i vatten Använd aldrig tryckfiltret om det finns människor i dammen Det får inte användas pumpar med större kapacitet än de som filterproducenten rekommenderat Filtret SKALL regelbundet rengöras Det får aldrig arbeta med ett vattentryck högre än 0 2 Bar 2 meters lyfthöjd Ett högre arbetstryck i fil...

Страница 9: ...trets inre kammare D Biologisk rening Filtersvamparnas porer skapar en stor biologisk yta där de nyttiga nedbrytnings bakterierna får fäste De gula och blå filtersvamparna har olika portäthet Det skapar zoner med olika genomsläpplighet och syreinnehåll för olika sorters av bakterier Zoner med en kraftig genomsläpplighet blå passar för syrekrävande bakterier som bryter ner ammoniak till nitrit via ...

Страница 10: ...att bibehålla sin goda funktion Slam och smuts kommer med tiden att blockera filtersvamparna som då måste rengöras Du märker att trycket minskar på utloppet eller oklart vatten kommer ur filtret Det är en god idé att rengöra filtersvamparna ca var 14 de dag eller om du märker att flödet minskar 1 Öppna rengöringskranen eller montera dit en slangadapter 2 Skruva funktionsvredet till läge BACKSPOLNI...

Страница 11: ... elektriska delarna Vinter Efter och försäsong förvaring och underhåll Innan filtret tas i drift för säsongen skall alla O ringar smörjas med silikonfett UV C lampan skall bytas 1 gång år även om den lyser Det kan ligga plastrester i kvartsglaset dessa kan bara kastas Det är delar av ett plastskydd som slitits upp av UV C strålarna Delen fyllde sitt syfte under filtrets transport och behövs ej län...

Страница 12: ...n står i läge P Defekt eller för gammal UV lampa Byt UV lampa Fel i elanslutningen Kolla anslutningarna Lampan är gammal Lampan skall bytas efter cirka 7 000 timmar Inget vatten från filtret Funktionsvredet står på CLEAN Sätt vredet i läge FILTER Pumpen pumpar inte Kontrollera elanslutningen Filtrets utloppsadap tor är blockerad Rengör utloppet Renoveringssats Bioclear XL O ring för montering mell...

Страница 13: ...östation Pondteam är med i elkretsen för återvinning av elavfall och REPA för återvinning av emballage Tryckfilter Bioclear XL 40000 Modell 2019 Bruksanvisning www pondteam com Pondteam AB Mossvägen 17 23237 Arlöv Sverige www pondteam com Tlf 0045 44669909 Fax 0045 44669919 Mail info pondteam com Reservation för tryckfel Copyright Pondteam AB 7 9 2022 Tryckfilter Bioclear XL 40000 Model 2019 Brugs...

Страница 14: ...er ikke er tilstrækkelige for at kunne forstå og anvende udstyret Anvend aldrig trykfiltret hvis der er personer i vandet Der må ikke anvendes pumper med større ydelse end anvist af producenten og filteret SKAL løbende renses Filteret må derfor aldrig køre med et højere driftstryk end 0 2 Bar 2 meter løftehøjde Et højere driftstryk vil forårsage utætte O ringe og følgeskader som f eks at filteret ...

Страница 15: ...vampene før vandet løber gennem hele filtrets højde fra ydersiden ind i filtrets indre kammer D Biologisk rensning Filtersvampenes porer danner en stor indre overflade som mikroorganismerne kan kolonisere De gule og de blå filtersvampe har forskellig størrelse og tæthed Dette skaber zoner hvor vandet bevæger sig med forskellig fart Zoner med en kraftig vandbevægelse blå filtersvampe passer tilkolo...

Страница 16: ...oldelsesfrit men filtersvampene skal dog rengøres regelmæssigt Filteret udsættes gennem drift og sæsonudsving for påvirkninger og slitage som kræver løbende vedligeholdelse Opslæmmede materialer og snavs vil med tiden fylde filtersvampene og dette vil efterhånden reducerer filterets effektivitet Hvis trykket i udløbet falder eller hvis der ligefrem kommer snavset vand ud af filtret skal filtret re...

Страница 17: ...vil senest kunne opdages ved nedtagning rensning og vinteropbevaring af produktet Vinter Sæsonmæssig vedligeholdelse og opbevaring Før filteret startes op i foråret skal O ringe efterses og smøres med silikone fedt og UV røret skal udskiftes Der kan ligge plastrester i kvartsglasset der stammer fra oprindelige afstands stykker transportsikring som er blevet nedbrudt af UV lyset Disse kan blot fjer...

Страница 18: ... lampen Fejl i el forbindelsen Tjek de elektriske Installationer Lampen er udbrændt Skal skiftes efter ca 7000 timers drift Intet vand fra filter til bassin Funktionsknappen står på Returskyl Skift funktionsknappen til FILTER Der er ikke tændt for pumpen Tænd for pumpen Filtrets udløbsstuds er blokeret Rens udløbsstuds Renoveringssæt Bioclear XL O ring til montering mellem filterbeholderens overka...

Страница 19: ...40862 18 Låg Lock Lid 40868 19 Filtersvamp sæt 7 stk Filtersvamp set 7 st Filter sponge set 7 pcs 40714 20 Låseplade Låsplatta Locking plate 21 Beskyttelsesrør Skyddsrör Protective pipes 22 Spændebånd Spännring Tension ring 40856 23 O ring beholder O ring behållare O ring container 40713 24 Låg filterbox Lock filterbox Lock filter box 25 Biobolde Biobollar Bioballs 26 Filterbox Filterbox Filterbox...

Страница 20: ...illbehörspåse komplett Art nr 40850 Slangekoblinger Slangkopplingar Slangkopplingar Afløbehane Avloppskran Avloppskran Omløbere til slange koblinger Lösringar till slang kopplingar Lösringar till slang kopplingar Fladpakninger til slangekoblinger Flatpackningar till slangkopplingar Flatpackningar till slangkopplingar 50 mm 2 Art no 40852 40867 Håndtag til rengøring med pakning Vev för rengöring me...

Страница 21: ...n til at ændre produkter specifikationer App s og anbefalinger uden varsel Affaldshåndtering En defekt pumpe må ikke lægges i den normale dagrenovation men skal indleveres på en af hjemkommunens genbrugspladser for el materiel f eks en miljøstation Pondteam AB Mossvagen 17 23237 Arlov Sweden www pondteam com Mail info pondteam com Forbehold for trykfejl Copyright Pondteam AB 7 9 2022 Bioclear XL 4...

Отзывы: