Ha Storing of Panels

Handling 

• 

When a

3

 CeramicSteel panels are shipped, they 

are protected by craft paper or a self-adhesive 
transparent polyethylene film. Keep panels in the 
original package until installation. 

• 

Handle with care to prevent damage.

• 

Never slide panels off the stack during handling. 
Panels should always be lifted and moved in a 
vertical position.

• 

Never place an a

3

 panel in a vertical position on 

the floor. This is to prevent damage to the edges.

• 

Prevent dirt from settling on and between panels 
to avoid surface damage, scratches or defects.

• 

Follow all safety instructions regarding personal 
protection when processing the panels.

• 

Protect panel surface against sawdust and 
sparks (metal particles).

• 

a

3

 CeramicSteel will chip when cut or drilled with 

power tools. Hand-cutting can cause chipping 
up to approx. 2 mm from the edge. When 
chipping is in excess of 2 mm, please check the 
state of cutting tools and check that the panel is 
adequately supported and clamped to prevent it 
from vibrating.

• 

All cut or drilled sections should be protected 

against humidity with PVC tape and/or by 
covering/sealing profiles or sealing washers.

• 

For detailed processing instructions, please refer 
to the a

3

 processing instructions.   

Storing

•  Keep panels dry and free of debris.

•  Store panels inside temps 50-90 °F (10-32 °C).

•  Any panels stored outside should be protected 

from inclement weather conditions.

•  Place panels on hard, flat surfaces that are not 

subject to standing water.

•  a

3

 CeramicSteel panels should be stacked no 

more than three high.

•  Panels should never be stored vertically or in 

such a way that the corners are vulnerable to 
damage.

If you have a problem, question, or a request, call 
your local fabricator, your regional sales manager 
or PolyVision Customer Service. PolyVision’s global 
customer service team can be contacted on 
polyvision.com.

Table 1 Horizontal Installation

Product

Weight (kg/lb)/panel

Frameless Flow 1830

28 kg / 61.73 lb

Frameless Flow 2420

37 kg / 81.57 lb

• 

Drill

• 

#2 Bit

• 

Glass suction cup lifters (2)

• 

Pliers

• 

Pencil

• 

Level or laser

• 

2 or 3-step ladder

•  Tape measure

Required Mat Equipment

Required Equipment 

Materials Provided 

NOTE: Items are not drawn to scale. Quantity of wall anchors and screws will vary per product 
due to the various widths. Board size determines the quantity of anchors and screws.*

Horizontal wall brackets

Vertical wall brackets

Horizontal oriented panels  

 

or vertical oriented panels

Anchors

Screws

Table 2

Product

Panel A (right)

Panel B (intermediate)

Panel C (left)

# Vertical 

Brackets

# Horizontal 

Brackets

# Screws/   

Anchors

# Vertical 

Brackets

# Horizontal 

Brackets

# Screws/   

Anchors

# Vertical 

Brackets

# Horizontal 

Brackets

# Screws/   

Anchors

Vertical Frameless Flow

Frameless Flow 1830

1

2

17

1

2

17

0

2

10

Frameless Flow 2420

1

3

24

1

3

24

0

3

15

Horizontal Frameless Flow

Frameless Flow 1830

1

2

15

1

2

15

0

2

10

Frameless Flow 2420

1

2

25

1

2

25

0

2

20

Frameless Flow Panels

Panel A

Right

Panel B

Intermediate

Panel C

Left

Doc # 143200 | Rev A | Page 5 of 38

Doc # 143200 | Rev A | Page 4 of 38

Содержание a3 CeramicSteel Flow 1830

Страница 1: ...CeramicSteel Flow Frameless Application Installation Guide Guidelines for installing your new a3 CeramicSteel Frameless Flow Americas 2019 English Espa ol Fran ais Canadien Doc 143200 Rev A Page 1 of...

Страница 2: ...24 centers Must be at least 2 x 12 5 mm 49 Type X gypsum drywall 35 mm 1 34 drywall screws on 250 mm 12 centers Verify Wall Construction CAUTION Adequate wall construction is required to support the w...

Страница 3: ...ls on hard flat surfaces that are not subject to standing water a3 CeramicSteel panels should be stacked no more than three high Panels should never be stored vertically or in such a way that the corn...

Страница 4: ...ed and fixed firmly Repeat for all the brackets Frontview Frameless Flow 2420 Vertical Wall Bracket Positioning 1 Define the centerline of the Frameless Flow installation 2 Define the centerline of pa...

Страница 5: ...rmly Repeat for all the brackets Frontview Frameless Flow 2420 Horizontal Wall Bracket Positioning 1 Define the centerline of the Frameless Flow installation 2 Define the centerline of panel A and pan...

Страница 6: ...al profile and fix the profile at the area where the profile touches the wall Make sure the profile is fixed at least on top middle and bottom Make sure the vertical profile is inserted completely in...

Страница 7: ...not covered by the Accessories warranty Should any failure to conform to this warranty become apparent then upon written notice from the customer PolyVision at its option will correct such nonconform...

Страница 8: ...0 mm 24 como m ximo Al menos 2 paneles de yeso tipo X de 12 5 mm 0 49 Tornillos para panel de yeso de 35 mm 1 34 con centros a 250 mm 12 Verificar la construcci n de la pared ADVERTENCIA La construcci...

Страница 9: ...superficies duras y planas en las que no se estanque agua Los paneles a3 CeramicSteel no deben guardarse en pilas de m s de tres Los paneles nunca deben almacenarse verticalmente o de forma tal que la...

Страница 10: ...os Repita con todos los soportes Vista de frente Frameless Flow 2420 Posicionamiento del soporte vertical de pared 1 Determine la l nea central de la instalaci n de Frameless Flow 2 Determine la l nea...

Страница 11: ...ta con todos los soportes Vista de frente Frameless Flow 2420 Posicionamiento del soporte horizontal de pared 1 Determine la l nea central de la instalaci n de Frameless Flow 2 Determine la l nea cent...

Страница 12: ...al rea donde toca la pared Aseg rese de que el perfil est firme al menos en las partes superior intermedia e inferior Verifique que el perfil vertical est introducido completamente en la ranura a todo...

Страница 13: ...cumplimiento de todas las obligaciones de PolyVision con respecto a la calidad de CeramicSteel La garant a es v lida nicamente en condiciones de uso y mantenimiento normales y no cubre defectos result...

Страница 14: ...type X en gypse de 12 5 mm 0 49 po Vis de la cloison s che de 35 mm 1 34 po et d une distance entre axes de 250 mm 12 po V rifier la construction murale AVERTISSEMENT Une construction murale ad quate...

Страница 15: ...ux sur des surfaces dures et planes qui ne sont pas sujettes la pr sence d eau stagnante Ne pas empiler plus de trois panneaux a3 CeramicSteel Les panneaux ne doivent jamais tre entrepos s la vertical...

Страница 16: ...es pour tous les supports Vue de face Tableau sans cadre Flow Positionnement des supports muraux verticaux 2420 1 D terminer la ligne centrale du tableau sans cadre Flow 2 D terminer la ligne centrale...

Страница 17: ...s pour tous les supports Vue de face Tableau sans cadre Flow Positionnement des supports muraux horizontaux 2420 1 D terminer la ligne centrale du tableau sans cadre Flow 2 D terminer la ligne central...

Страница 18: ...e profil vertical et le fixer l endroit o celui ci touche le mur S assurer que le profil est fix au moins dans le haut au milieu et dans le bas S assurer que le profil vertical est compl tement ins r...

Страница 19: ...x cution de toutes les responsabilit s de PolyVision en ce qui a trait la qualit de CeramicSteel La pr sente garantie s applique uniquement l utilisation et l entretien normaux du produit et ne couvre...

Страница 20: ...l and to discontinue any product or material without notice polyvision com 30 10 2019 PolyVision Americas 10700 Abbotts Bridge Road Suite 100 Johns Creek GA 30097 USA T 1 888 325 6351 E info polyvisio...

Отзывы: