background image

 

 
1.   Hazard and safety information 

 

   

Power supply and power cord 

   

The device must be operated only at a power supply with a voltage  

   

of 230 V / 50 Hz. 

 

   

Connection cable  

   

Place the connection cable always trip proof !  

   

Replace the power cord only with an original power cord. 

 

 

Potential equalization / grounding 

 

Proper grounding and installation of the device must be carried out according to EN 60728-11 / VDE 
0855-1 regulations. 

 

Operation without grounding or potential equalization of equipment is not allowed. 

 

 

Humidity and placement location 

 

The device must not be exposed to dripping or splashing  water. If water condensation occurs,  wait 
until the device is completely dry. The device must be installed on a vibration-free location. 

 

 

 

Ambient temperature and heat effect 

 

 

The maximum allowable ambient temperature is 50 ° C.

  

 

The ventilation holes of the device must NOT be covered under any circumstances. Too much heat 
or heat accumulation affect the life of the device and can be a source of danger. 

 

To prevent heat buildup and to ensure good ventilation, the device must be mounted horizontally (eg. 
on  a  wall).  The  device  must  not  be  mounted  above,  on  top,  or  near  heat  sources  (e.g  radiators, 
heating plants), where the device is exposed to heat radiation or oil vapors. The installation must be 
done  only  in  rooms  that  ensure  compliance  with  the  permissible  ambient  temperature  range,  even 
under changing climatic conditions. 

 

 

 

Warning:

  

When installed in rooms such as storage or attic one should pay particular attention on compliance 
with the ambient temperature. Because of the danger of fire due to overheating or lightning strike, it 
is recommendable to install the device on a noncombustible surface. Combustible surfaces are wood 
beams or bars, wood boards, plastic materials, etc. 

 

Conditions to ensure electromagnetic compatibility (EMC)

 

All  covers,  screws  and  connectors  must  be  securely  mounted  and  tightened,  contact  springs  must 
not be bent or oxidized.

 

Содержание TSM 1000 HD-C

Страница 1: ...TSM 1000 HD C TSM 1000 HD CF User Manual MADE IN GERMANY 0901743 V1...

Страница 2: ...1 Software installation 9 8 1 1 Installing the driver 9 8 1 2 Installing the programming software 10 8 2 Programming the device parameters 10 8 2 1 Input parameters 11 8 2 2 Output parameters 13 8 3 S...

Страница 3: ...der any circumstances Too much heat or heat accumulation affect the life of the device and can be a source of danger To prevent heat buildup and to ensure good ventilation the device must be mounted h...

Страница 4: ...rostatic sensitive components can be processed only on electrostatic protected area EPA Pay attention permanently to potential equalization equipotential bonding Use wrist straps approved footwear for...

Страница 5: ...g satellite grade coaxial distribution network It does not matter if it is a network with a star tree or mixed structure Viewers can receive all the TV channels located on the transponders via a comme...

Страница 6: ...unit to allow air to circulate freely To perform any assembly work or when working on the cabling the power plug must first be unplugged 6 1 Earthing grounding The device must be earthed in accordance...

Страница 7: ...for the LNB supply is not lit the LNB supply will be interrupted or disrupted Please note The overall current consumption of all the LNBs connected must not exceed 500mA 7 1 TSM 1000 HD C input assign...

Страница 8: ...amming the device see Point 9 2 2 Output OUT USB LED 8 Programming in general After connecting the power supply cable the device runs through an internal routine and all 10 channels are set to the dat...

Страница 9: ...om the USB flash drive supplied 8 1 1 Installing the driver Start Instal_driver cmd Follow the instructions on the screen With some initial installations the following dialog may appear This depends o...

Страница 10: ...computer with the USB cable once the programming software has been installed on the computer 8 2 0 Programming the device parameters Launch the SATIF10 program Click the top left Menu The following me...

Страница 11: ...t of the menu An existing program can be saved or loaded using the Settings menu item See Point 9 3 8 2 1 Input parameters IN Selection of the input signal source TSM 1000 HD C Select the desired Sat...

Страница 12: ...HER frequency 8 2 2 Output parameters SAT IF SAT IF frequency output frequency When using the TSM SAB 09 filter the pre programmed output frequency should be maintained The desired SAT IF is set here...

Страница 13: ...et in 1 dB steps from 0 to 12 The difference between the various transponders should not be more than 2 dB By making appropriate settings it is possible to compensate for any cable attenuation from di...

Страница 14: ...sk before the f10 file extension must be replaced by a name The file name must retain the f10 extension In addition a rtf file is also stored this can be used to print out the parameters This file is...

Страница 15: ...Update via laptop PC Call up the Firmware Update menu item Click on the Update button the latest software will be loaded Firmware update via a USB flash drive Download the SATIF10_FW_xxx UC3 file from...

Страница 16: ...SAB 09 filter Example 28 transponders through the TSM SAB 09 filter Please refer to the extra sheet on pre programming for details of the passband of the filter and the current pre programming Exampl...

Страница 17: ...eps 1 MHz Remote feed every 12 V 250 mA input 1 4 LNB current max 500 mA Output frequency range 950 2150 MHz Output level 97 dB V Attenuator 12 dB Connectors FC Operating voltage 190 250 V 50 60 Hz Po...

Страница 18: ...18 11 Declaration of Conformity...

Страница 19: ...19...

Страница 20: ...dvice and assistance You can make use of this service and call us from Monday to Friday 7 30 a m to 4 30 p m at Technical advice 49 0 7081 1702 12 If an emergency outside occurs office hours you can c...

Отзывы: