![Polytron Headend Series Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/polytron/headend-series/headend-series_user-manual_1578207036.webp)
36
8.7.1 Creating headends
Start the program
–
SATC12
–
In the menu item
Control,
activate the submenu
LAN-Control
,
to enable the control via LAN.
To create the connection settings of the PXU 848 X in the
Control
menu, select the submenu
Edit Headends
.
The input window in which to enter the headend access data will be opened.
Click the button
Add New
. The menu fields are now enabled for data input.
The following settings must be made:
Name:
Enter the name of the device (freely selectable)
Location:
Enter the name of the location (freely selectable)
IP-Adress:
Enter the IP address of the headend to be controlled
(Factory setting 192.168.001.227)
Port:
Enter the port of the headend to be controlled
(Factory setting 10001)
192.168.001.221
Bad Wildbad
Test
10004