background image

 

Section 1 - General Information 

1.1  

Warranty 

Thank you for purchasing this circulator.  We are confident it will serve you for a long time.  Our 
warranty to you is as follows: 

The manufacturer agrees to correct for the original user of this product, either by repair, or at the 

manufacturer's election, by replacement, any defect that develops after delivery of this product 

within the period as stated on the warranty card.  In the event of replacement, the replacement unit 

will be warranted for 90 days or warranted for the remainder of the original unit’s parts or labor 

warranty period, whichever is longer. 

If this product requires service, contact the manufacturer/supplier's office for instructions. When 

return of the product is necessary, a return authorization number will be assigned and the product 

should be shipped, (transportation charges pre-paid), to the indicated service center.  To insure 
prompt handling, the return authorization number should be placed on the outside of the package 

and a detailed explanation of the defect enclosed with the item. 

This warranty shall not apply if the defect or malfunction was caused by accident, neglect, 

unreasonable use, improper service, or other causes not arising out of defects in material or 

workmanship. There are no warranties, expressed or implied, including, but not limited to, those of 

merchantability or fitness for a particular purpose which extends beyond the description and period 

set forth herein. 

The manufacturer's sole obligation under this warranty is limited to the repair or replacement of a 
defective product and shall not, in any event, be liable for any incidental or consequential damages 

of any kind resulting from use or possession of this product.  Some states do not allow: (A) 

limitations on how long an implied warranty lasts; or (B) the exclusion or limitation of incidental or 

consequential damages, so the above limitations or exclusions may not apply to you.  This warranty 

gives you specific legal rights.  You may have other rights that vary from state to state. 

1.2 

Unpacking 

Your circulator is shipped in a special carton.  Retain the carton and all packing materials until the 

unit is completely assembled and working properly.  Set up and run the unit immediately to confirm 

proper operation.  Beyond one week, your unit may be warranty repaired, but not replaced.  If the 
unit is damaged or does not operate properly, contact the transportation company, file a damage 

claim and contact the company where your unit was purchased immediately. 

Remove any loose packing material that may have fallen into the reservoir during shipping. Before 

powering up, check that nothing remains around the heater or circulator pump.   

The instructions in this manual pertain to both circulating baths as well as the immersion circulator.  

Read the section pertaining to the special instructions for your model, then review the instructions for 

all models of circulators. 

 

 

This symbol marks chapters and sections of this instruction manual which are particularly relevant to safety.   

 

 

This symbol indicates that hazardous voltages may be present.

 

 

Read all instructions pertaining to safety, set-up, and operation. 

Proper operation is the users’ responsibility. 

 

Содержание Standard Controller

Страница 1: ...Operators Manual Standard Controller Models Pages 1 22 Manuel de l utilisateur Mod les du Contr leur Standard Pages 21 37 Bedienungsanleitung Ger te mit Standardregelung Seiten 38 54 110 227 1 8 08...

Страница 2: ...D 1150S 1157P 1196D 1190S 1197P 1186D 1180S 1187P 1136D 1130S 1137P 1136 1D 1130 1S 1137 1P 1136 2D 1130 2S 1137 2P 12110 00 12110 05 12112 01 12112 06 12112 11 12112 16 12112 12 12112 26 12100 10 121...

Страница 3: ...rces prudently and rationally Specific treatment of WEEE is indispensable in order to avoid the dispersion of pollutants into the recycled material or waste stream Such treatment is the most effective...

Страница 4: ...130S 1137P 1136 1D 1130 1S 1137 1P 1136 2D 1130 2S 1137 2P 12110 00 12110 05 12112 01 12112 06 12112 11 12112 16 12112 12 12112 26 12100 10 12100 15 12100 20 12100 25 12108 00 12108 05 12108 20 12108...

Страница 5: ...0S 1137P 1136 1D 1130 1S 1137 1P 1136 2D 1130 2S 1137 2P 12110 00 12110 05 12112 01 12112 06 12112 11 12112 16 12112 12 12112 26 12100 10 12100 15 12100 20 12100 25 12108 00 12108 05 12108 20 12108 25...

Страница 6: ...tting the Safety Set Set Point 5 5 Selecting Temperature Units 5 6 Setting the Software High Limit 5 7 Setting the Set point Temperature 5 8 User Defined Preset Temperatures 5 9 Local Lockout Feature...

Страница 7: ...is warranty is limited to the repair or replacement of a defective product and shall not in any event be liable for any incidental or consequential damages of any kind resulting from use or possession...

Страница 8: ...ration at temperatures below 40 C However refrigeration should not be used when the fluid temperature is above 55 C Refrigeration should not be turned on when the ambient air temperature is above 32 C...

Страница 9: ...h the unit are intended for applications from 40 C to 93 C For applications above 93 C brass stainless steel or Teflon fittings are recommended inch NPT to M16 stainless steel male adapter fittings ar...

Страница 10: ...for a wide variety of applications Model Type Temperature Range Reservoir Capacity Amps 120V 60Hz Amps 240V 50Hz Heat Only Immersion Circulator Ambient 5 C to 150 C N A 11A 7 5A 3 3 Circulator Pump Th...

Страница 11: ...ing over the rotating pump outlet nozzle and fasten it in place with a hose clamp Connect the other end of the tubing to the inlet of the external apparatus Be sure to run tubing from the outlet of th...

Страница 12: ...eset Button 13 Pump Inlet 2 4 Safety Set Indicator Knob 14 Reservoir Purge 2 5 Cooling Light 1 15 Pump Outlet 2 6 Power ON OFF Button 16 AC Input 7 Heating Light 17 Circuit Breaker AC Power Switch 8 F...

Страница 13: ...the Circulator on a level surface free from drafts and out of direct sunlight Do not place it where there are corrosive fumes excessive moisture high room temperatures or excessive dust is present Re...

Страница 14: ...After filling the reservoir with fluid you must set the Safety Set and the Software High Limit as well as your desired control set point temperature 5 4 Setting the Safety Set Set Point The Safety Set...

Страница 15: ...the problem is corrected bath temperature reduced or Software High Limit value increased press the Power button to clear the message 5 7 Setting the Set Point Temperature Press and release the Select...

Страница 16: ...ons a set point 15 C above room temperature is recommended Cool Command Refrigeration Refrigerating Heating Circulators with 13 and 28 liter reservoirs feature the advanced Cool Command modulating ref...

Страница 17: ...FLt 5 Probe failure Error Service required FLt 6 i2c error Communication failure to modulation board Error Service required Appears only on Refrigerating Heating Circulators Section 6 Calibration and...

Страница 18: ...ing capacity the condenser the front and back air vents and reusable filter should be kept free of dust and dirt They should be checked on a scheduled basis and cleaned as required The reusable filter...

Страница 19: ...o stabilize when changes in heat load or set point are made 7 6 No Cooling or Insufficient Cooling Check that the Cooling switch is ON If the cooling light is not lit check the control temperature set...

Страница 20: ...RMAL EXTREME 25 C RANGE RANGE Distilled Water 1 00 10 90 C 2 100 C Ethylene Glycol 30 Water 70 90 0 95 C 15 107 C Ethylene Glycol 50 Water 50 82 20 100 C 30 100 C Dynalene HC 50 76 50 60 C 62 60 C DC2...

Страница 21: ...s high temperature extreme 1 Heat loss from vapor adversely affects temperature stability 2 To prevent the accumulation of vapors inside the room the reservoir may need to be placed in a fume hood 3...

Страница 22: ...Refrigerating Heating and Heating Only models 120V 525 525 Pump Motor Refrigerating Heating and Heating Only models 240V 525 526 Pump Motor Immersion Circulators 120V 525 527 Pump Motor Immersion Cir...

Отзывы: