EC Declaration of Conformity 

 

The Products herewith complies with the requirements, as stated below, in accordance to the EC Low Voltage 
Directive 73/23/EEC and EC Electromagnetic Compatibility Directive 89/336/EEC, and carries the 

 marking 

accordingly. 
We herewith declare:   
 

PolyScience 
Division of Preston Industries, Inc. 
6600 West Touhy Avenue 
P.O. Box 48312 
Niles, Illinois 60714, USA 

That the following equipment complies with the essential requirements in respect to safety and health, in 
accordance to the EC Directives based on its design and type, as brought into circulation by us. In case of 
alteration of the equipment, not agreed upon by us, this will lose its validity. 

Product Description: 

Refrigerated/Heated Circulators 
13R, 712, 7306, 7312, 812, 8006, 8012, 8002, 8112, 8102, 8106, 8202, 
8212, 8206, 8306, 9006, 9012, 9002, 912, 9112, 9102, 9106, 9502, 9512, 
9506, 9602, 9612, 9606, 9702, 9712, 9706; 
 
18203, 18214, 18211, 18210, 18201, 18206, 18205, 18208, 18212, 18207, 
18225, 18226, 18202;  
 
13270-879, 13270-880, 1112A, 1122S, 1127P, 1146D, 1140S, 1147P, 
1162A, 1166D, 1160S, 1167P, 1156D, 1150S, 1157P, 1196D, 1190S, 
1197P, 1186D, 1180S, 1187P, 1136D, 1130S, 1137P, 1136-1D, 1130-1S, 
1137-1P, 1136-2D, 1130-2S, 1137-2P; 
 
12110-00, 12110-05, 12112-01, 12112-06, 12112-11, 12112-16, 12112-
12, 12112-26, 12100-10, 12100-15, 12100-20, 12100-25, 12108-00, 
12108-05, 12108-20, 12108-25, 12108-10, 12108-15, 12108-30, 12108-
35, 12102-10, 12102-15, 12102-00, 12102-05, 12103-20, 12103-25, 
12105-70, 12105-75, 12101-41, 12101-46, 12101-31, 12101-36, 12101-
51, 12101-56, 12111-11, 12111-16, 12111-01, 12111-06, 12111-21, 
12111-26, 12107-00, 12107-05, 12107-20, 12107-25, 12107-10, 12107-
15, 12107-30, 12107-35, 12107-50, 12107-55, 12107-40, 12107-45, 
12107-60, 12107-65, 98928-30, 98928-35. 

Applicable Directives  
and Harmonized Standards: 
 

 
Low Voltage Directive 73/23/EEC & Electromagnetic Compatibility 
89/336/EEC and relevant transpositions into national law of the 
member states, including, but not limited to the following 
Harmonized Standards: 
EN/IEC 61010-1: 2001  
EN/IEC 61010-2 
EN 61326: 1997 +A1: 1998 + A2:2001 
CISPR 11/EN 55011 Class A, Group I 
 

Testing Bodies:  
 

CSA International (Certification & Testing Division) 
Ultra Tech Inc. ( EMC approval)  

Signature on Behalf of 
Manufacturer or Authorized 
Representative: 
Date of Validity: 
Title of Signatory: 

 

Brian Klotz 
October 18, 2005 
Engineering Manager 

110-254 Rev. E  10/05 

 

Содержание Standard Controller

Страница 1: ...Operators Manual Standard Controller Models Pages 1 22 Manuel de l utilisateur Mod les du Contr leur Standard Pages 21 37 Bedienungsanleitung Ger te mit Standardregelung Seiten 38 54 110 227 1 8 08...

Страница 2: ...D 1150S 1157P 1196D 1190S 1197P 1186D 1180S 1187P 1136D 1130S 1137P 1136 1D 1130 1S 1137 1P 1136 2D 1130 2S 1137 2P 12110 00 12110 05 12112 01 12112 06 12112 11 12112 16 12112 12 12112 26 12100 10 121...

Страница 3: ...rces prudently and rationally Specific treatment of WEEE is indispensable in order to avoid the dispersion of pollutants into the recycled material or waste stream Such treatment is the most effective...

Страница 4: ...130S 1137P 1136 1D 1130 1S 1137 1P 1136 2D 1130 2S 1137 2P 12110 00 12110 05 12112 01 12112 06 12112 11 12112 16 12112 12 12112 26 12100 10 12100 15 12100 20 12100 25 12108 00 12108 05 12108 20 12108...

Страница 5: ...0S 1137P 1136 1D 1130 1S 1137 1P 1136 2D 1130 2S 1137 2P 12110 00 12110 05 12112 01 12112 06 12112 11 12112 16 12112 12 12112 26 12100 10 12100 15 12100 20 12100 25 12108 00 12108 05 12108 20 12108 25...

Страница 6: ...tting the Safety Set Set Point 5 5 Selecting Temperature Units 5 6 Setting the Software High Limit 5 7 Setting the Set point Temperature 5 8 User Defined Preset Temperatures 5 9 Local Lockout Feature...

Страница 7: ...is warranty is limited to the repair or replacement of a defective product and shall not in any event be liable for any incidental or consequential damages of any kind resulting from use or possession...

Страница 8: ...ration at temperatures below 40 C However refrigeration should not be used when the fluid temperature is above 55 C Refrigeration should not be turned on when the ambient air temperature is above 32 C...

Страница 9: ...h the unit are intended for applications from 40 C to 93 C For applications above 93 C brass stainless steel or Teflon fittings are recommended inch NPT to M16 stainless steel male adapter fittings ar...

Страница 10: ...for a wide variety of applications Model Type Temperature Range Reservoir Capacity Amps 120V 60Hz Amps 240V 50Hz Heat Only Immersion Circulator Ambient 5 C to 150 C N A 11A 7 5A 3 3 Circulator Pump Th...

Страница 11: ...ing over the rotating pump outlet nozzle and fasten it in place with a hose clamp Connect the other end of the tubing to the inlet of the external apparatus Be sure to run tubing from the outlet of th...

Страница 12: ...eset Button 13 Pump Inlet 2 4 Safety Set Indicator Knob 14 Reservoir Purge 2 5 Cooling Light 1 15 Pump Outlet 2 6 Power ON OFF Button 16 AC Input 7 Heating Light 17 Circuit Breaker AC Power Switch 8 F...

Страница 13: ...the Circulator on a level surface free from drafts and out of direct sunlight Do not place it where there are corrosive fumes excessive moisture high room temperatures or excessive dust is present Re...

Страница 14: ...After filling the reservoir with fluid you must set the Safety Set and the Software High Limit as well as your desired control set point temperature 5 4 Setting the Safety Set Set Point The Safety Set...

Страница 15: ...the problem is corrected bath temperature reduced or Software High Limit value increased press the Power button to clear the message 5 7 Setting the Set Point Temperature Press and release the Select...

Страница 16: ...ons a set point 15 C above room temperature is recommended Cool Command Refrigeration Refrigerating Heating Circulators with 13 and 28 liter reservoirs feature the advanced Cool Command modulating ref...

Страница 17: ...FLt 5 Probe failure Error Service required FLt 6 i2c error Communication failure to modulation board Error Service required Appears only on Refrigerating Heating Circulators Section 6 Calibration and...

Страница 18: ...ing capacity the condenser the front and back air vents and reusable filter should be kept free of dust and dirt They should be checked on a scheduled basis and cleaned as required The reusable filter...

Страница 19: ...o stabilize when changes in heat load or set point are made 7 6 No Cooling or Insufficient Cooling Check that the Cooling switch is ON If the cooling light is not lit check the control temperature set...

Страница 20: ...RMAL EXTREME 25 C RANGE RANGE Distilled Water 1 00 10 90 C 2 100 C Ethylene Glycol 30 Water 70 90 0 95 C 15 107 C Ethylene Glycol 50 Water 50 82 20 100 C 30 100 C Dynalene HC 50 76 50 60 C 62 60 C DC2...

Страница 21: ...s high temperature extreme 1 Heat loss from vapor adversely affects temperature stability 2 To prevent the accumulation of vapors inside the room the reservoir may need to be placed in a fume hood 3...

Страница 22: ...Refrigerating Heating and Heating Only models 120V 525 525 Pump Motor Refrigerating Heating and Heating Only models 240V 525 526 Pump Motor Immersion Circulators 120V 525 527 Pump Motor Immersion Cir...

Отзывы: