background image

18

www.sousvideprofessional.com

Restore factory defaults.

 To reset your Circulator to all factory settings, 

unplug the unit from the electrical outlet and plug it back in again while 
pressing either the      (for degrees C) or the       (or degrees F).

Disposal.

This equipment is marked with the crossed out wheeled bin symbol to 
indicate that it must not be disposed of with unsorted waste.

It is your responsibility to correctly dispose of this equipment at 
lifecycle-end by handing it over to an authorized facility for separate 
collection and recycling. By doing so, you will help to conserve natural 
and environmental resources and you will ensure that your equipment is 
recycled in a manner that protects human health. 

Please contact PolyScience. 

For recipe ideas, instructional videos, and free downloads visit  

www.sousvideprofessional.com

.

REGULATORY COMPLIANCE AND TESTING 
Part numbers beginning with “SVPR” 
120V units

:  

ETL Intertek: Conforms to UL STD 1026, Certified to CAN/CSA STD C22.2 No. 64.10

240V units

CE: Low Voltage Directive 2006/95/EC, Electromagnetic Compatibility Directive 2004/108/EC, 
IEC 61010-1-2001, EN 61326:2006 Emissions, EN 61326: 2006 Immunity 

Part numbers beginning with “SVC” 
120V units

ETL Intertek: Conforms to UL STD 197, Certified to CAN/CSA STD C22.2 No. 109 
ETL Sanitation: NSF / ANSI 8

240V units

ETL Sanitation: NSF / ANSI 8 
CE: Low Voltage Directive 2006/95/EC, Electromagnetic Compatibility Directive 2004/108/EC, 
IEC 61010-1-2001, EN 61326:2006 Emissions, EN 61326: 2006 Immunity

Содержание CHEF Series

Страница 1: ...110 493 101012 Innovative Culinary Technology...

Страница 2: ......

Страница 3: ...ped damaged or malfunctions Return the Circulator to PolyScience for examination and or repair 2 Do not let power cord touch hot surfaces or hang over the edge of table or counter 3 Unplug from electr...

Страница 4: ...liance should not be used by children To avoid accidental injury close supervision is necessary when this appliance is used where children may be present 11 Do not operate in the presence of explosive...

Страница 5: ...Vide Professional is equipped with an automatic over temperature safety that will disable the heater in the event of a heater fault or if it is run with insufficient cooking liquid for too long a time...

Страница 6: ...Sous Vide Professional warranty at www cuisinetechnology com warranty Advantages of Sous Vide Cooking t 4JHOJGJDBOUMZ SFEVDFT TISJOLBHF XIFO DPPLJOH NFBUT GJTI or poultry t FDBVTF GPPE JT WBDVVN TFBMF...

Страница 7: ...elping ensure that individual portions cook evenly and at the same rate t MFYJCMF o clamps securely to stock pots hotel pans and other cooking vessels turns vessels up to 30 liters 30 quarts into a so...

Страница 8: ...Sous Vide Professional 7 Controls Components Up Arrow Button Backlit Display Down Arrow Button Maximum Liquid Level Line Minimum Liquid Level Line Power Button Menu Button Front Flow Adjustment Slide...

Страница 9: ...www cuisinetechnology com 8 Mounting Clamp Removable Heater Pump Access Cover Rear Flow Adjustment Slide Heating Circulating Power Cord Actual Cooking Liquid Temperature Temperature Set Point...

Страница 10: ...information 1 Attach your Sous Vide Professional to the cooking vessel 2 Fill the vessel with tap water and cover with plastic wrap or lid 3 Connect the power cord to an electrical outlet 4 Turn the...

Страница 11: ...e Circulator housing and the bottom of the cooking vessel 3 Add the tap water to the cooking vessel The depth of the liquid in the cooking vessel should be kept somewhere between the Maximum and Minim...

Страница 12: ...ashing 6 Select the temperature units Your Circulator can be set to display temperature in either F factory default or C To change from F to C press once and then press To accept the change press or w...

Страница 13: ...int temperature is displayed To accept the displayed set point temperature press or wait for the word SET to stop flashing approximately 10 seconds Loss of Power In the event that electrical power is...

Страница 14: ...tor also features two more advanced functions These are accessed by pressing the Menu button Temperature Units Your Sous Vide Profession can display the set point and cooking liquid temperatures in ei...

Страница 15: ...he desired value 6 Press or wait for the LCD to return to the main operational display The Offset Calibration function will remain enabled until the electrical power is turned OFF by pressing the butt...

Страница 16: ...tergent for about 10 minutes at 140 F 60 C Rinse carefully and dry thoroughly when done Removing Mineral or Scale Deposits Depending on the frequency of use and the hardness of your water TDBMF BOE NJ...

Страница 17: ...use hard utensils or abrasive pads to remove trapped food debris Fault Warning Messages WARNING To avoid the potential for burns allow the Circulator to cool to room temperature before removing it fr...

Страница 18: ...If OVERTEMP OR LOW FLUID FAIL INTERNAL PROBE or FAIL 5 3 BQQFBST PO UIF JSDVMBUPS T EJTQMBZ UIFSF IBT CFFO BO JOUFSOBM component failure or the automatic over temperature safety temperature has been...

Страница 19: ...your equipment is recycled in a manner that protects human health Please contact PolyScience For recipe ideas instructional videos and free downloads visit www sousvideprofessional com REGULATORY COM...

Отзывы: