MAINTENANCE & TROUBLESHOOTING
What shall I do if the Nebulizer Warning Light is on?
If this happens during a polishing cycle, first try pressing the control knob and rotating
it clockwise to start a new polishing cycle. If the problem persists, try the following:
Check the nebulizer unit to see if it is installed properly.
Make sure the
nebulizer is fully seated in its socket.
Check if the reservoir is empty.
If this is the case, fill the reservoir, prime the
nebulizer and start a new polishing cycle to see if the problem has been solved.
In case that neither of the above can solve the issue, try replacing the nebulizer with a
new one (remember to prime the new nebulizer). If the problem is still on, contact us
for additional assistance.
Draining the reservoir
A 30 mL pipette is provided for removing alcohol from the reservoir. Avoid any heat
source, open flames or sparks when draining the reservoir. The alcohol, unless
contaminated, can be repeatedly used for polishing.
Removing the casing
The Polysher can be operated without the need to remove the casing. However, if it is
needed to fully remove the casing, follow the instructions below:
Raise the platform to the upmost position;
Lift the casing all the way up, gently flex the thin section outward and pull it off the
machine;
To put the casing back on, flex the thin section the same way and slide it through the
moving post. Make sure it seats exactly on the rubber seal of the base.
What shall I do if the mist volume is abnormally low?
In a typical polishing cycle, the alcohol mist should fill the entire chamber within
several minutes. If, however, the mist volume is observed to be low, or not reaching
the full height, check the reservoir to see if it is running low or empty, and refill it if
necessary.