ON/OFF:

 Press the button to power on the Polysher

TM

. Long press to turn off the 

Polysher

TM

OPEN/CLOSE:

 Push the button once to raise the platform of the Polysher

TM

. Press 

again to lower the platform. Press again during the movement to stop the action.

Control Dial:

 Twist the dial clockwise to start a polishing cycle. Dial clicks in 5 minute 

increments displayed by the lights above. Twist left to decrease the time or all the way 

to stop the polishing cycle. Press dial in during a polishing cycle then twist left or right 

to change the nebulizer light color.

Chamber Casing:

 Provides an air tight enclosure around the Polysher

TM

 while giving 

visibility to your part.

Nebulizer: 

The nebulizer cartridge is where liquid alcohol from the reservoir is 

turned into a fine aerosol that polishes your printed part. Inside the cartridge is a 

micromachined metal disc that vibrates hundreds of thousands of times per second. A 

sponge wick conducts the liquid solvent to the disc. The nebulizer unit can be removed 

by gently pulling up. To insert a replacement nebulizer, align the pins and gently press 

down.

Reservoir:

 Collects and stores alcohol feeding the wicking sponge and nebulizer. 

Reservoir Cover:

 Your Polysher

TM

 comes with two reservoir covers. One for use during 

operation with slots (“grate” style) to allow alcohol to flow through. The other is for use 

during storage to minimize alcohol evaporation.

Turn Table/Platform:

 Holds your PolySmooth

TM

 part during polishing. Turn Table 

rises up with platform to give access to polished parts. To remove the platform, use the 

handles on either side.

Chamber Lights:

 Press once to turn on the chamber lighting. Press again to turn off 

the chamber lighting. Chamber lights take 1-2 seconds to fully dim, press the button 

during this time to set current illumination.

Nebulizer Warning Light:

 Indicates a malfunction with the nebulizer, this could 

mean: not enough alcohol in the reservoir, a bad connection between the nebulizer 

and port, or a broken nebulizer that needs replacing. A polishing cycle cannot be 

started while this light is on. See the Troubleshooting section of this User Manual for 

instructions on how to correct these conditions.

Chamber Seal Warning Light:

 Indicates an air leak in the chamber. Readjust the 

chamber casing to ensure that it sits properly on the Polysher

TM

. A polishing cycle 

cannot be started while this light is on.

Priming the Nebulizer: 

To prime your nebulizer, suck some alcohol into the pipette. 

Then squeeze 5-10 drops of alcohol on the nebulizer membrane using the priming 

pipette to ensure the wicking sponge and nebulizer are saturated. Prime the nebulizer 

when using the Polysher

TM  

for the first time, or if the reservoir and the nebulizer have 

run dry. 

DC Power In

: The port for the DC power cable is located on the back of the Polysher

TM

ESSENTIAL PARTS OF THE POLYSHER

TM

1

2

3

4

5

6

7

8

9

10

11

12

13

Содержание Polysher

Страница 1: ...1 OPEN CLOSE CHAMBER LIGHTS ON OFF Polysher PolysherTM Operation Manual ...

Страница 2: ...中文说明书请访问 For other languages visit Pour les autres langues visitez Für andere Sprachen Besuch www polysher polymaker com ...

Страница 3: ...nformation on Disposal for Users of Waste Electrical Electronic Equipment Package Contents Essential Parts of the PolysherTM Setting up your PolysherTM Operating your PolysherTM Maintenance and Troubleshooting Contact Information CONTENTS 4 5 6 6 7 8 10 12 14 15 ...

Страница 4: ... based 3D printer The support structure comes off very easily as well making it ideal for complex geometries The real magic occurs when you put your PolySmoothTM prints into the PolysherTM With Polymaker s unique Micro Droplet Polishing technology the layer lines will magically disappear leaving you with a truly finished object with shiny smooth surfaces But this is just the beginning We will keep...

Страница 5: ...vice immediately and show the container or the label Do not block any ventilation openings Only use attachments accessories specified by the manufacturer Refer all servicing to qualified service personnel For Use Only with the supplied Power Supply or equivalent power supply acceptable to the manufacturer If you have any question regarding the safety of the PolysherTM please contact inquiry polyma...

Страница 6: ...local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with your national legislation SPECIFICATIONS Technology Compatible Material Polishing Liquid Polishing Time Product Dimensions Shipping Box Dimensions Product Weight Shipping Weight Maximum Part Size Operating Temperature Storage Temperatur...

Страница 7: ...d contain the following PACKAGE CONTENTS OPEN CLOSE CHAMBER LIGHTS ON OFF Polysher PolysherTM x1 Power Supply x1 Nebulizers x2 Priming pipette x1 Suction pipette x1 Grate style reservoir cover x1 Solid reservoir cover x1 Platforms x2 ...

Страница 8: ...er is for use during storage to minimize alcohol evaporation Turn Table Platform Holds your PolySmoothTM part during polishing Turn Table rises up with platform to give access to polished parts To remove the platform use the handles on either side Chamber Lights Press once to turn on the chamber lighting Press again to turn off the chamber lighting Chamber lights take 1 2 seconds to fully dim pres...

Страница 9: ...OPEN CLOSE CHAMBER LIGHTS ON OFF 5 6 7 12 3 2 4 8 9 1 13 10 11 ...

Страница 10: ...nd the blue ring around the On Off button should illuminate Open the PolysherTM Press the Open Close button The lift mechanism should rise to its fully open position and stop Install the Nebulizer Install a Nebulizer by firmly pressing it down into the socket Make sure the connection is satisfactory Fill the Reservoir Lifting up the transparent casing with one hand and use the suction pipette with...

Страница 11: ...time the top portion of the sponge will be dry and the nebulizer will not operate It is necessary to first prime the sponge by dribbling 5 10 drops of alcohol directly onto the nebulizer itself using the priming pipette The solvent will flow through the nebulizer s micromachined pores and into the sponge Install the Reservoir Cover Place the grate cover over the reservoir Install the Platform Set ...

Страница 12: ...hting can also be adjusted by pressing the control knob and then rotating it until you see the desired color Press the OPEN CLOSE button The lift mechanism will lower the part into the chamber and seal the top of the chamber The Chamber Seal warning light should turn off when the lift mechanism reaches its lower closed position If it doesn t check to see that the casing is properly seated You can ...

Страница 13: ...it solvent evaporation avoid vapor buildup in the chamber and prevent the nebulizer sponge from drying out If the nebulizer is left uncovered for several days the sponge may dry out and require re priming Dry the part You can now remove the platform from the PolysherTM Do not touch the part yet as the surface may be sticky and you may leave finger marks on the part The part should be left to dry f...

Страница 14: ...rovided for removing alcohol from the reservoir Avoid any heat source open flames or sparks when draining the reservoir The alcohol unless contaminated can be repeatedly used for polishing Removing the casing The Polysher can be operated without the need to remove the casing However if it is needed to fully remove the casing follow the instructions below Raise the platform to the upmost position L...

Страница 15: ...hanghai 200120 China E mail inquiry polymaker com facebook com Polymaker 3D Visit polymaker com and follow us on our social media channels for product updates videos tutorials and more twitter com Polymaker_3D youtube com Polymaker instagram com Polymaker_3D pinterest com Polymaker thingiverse com Polymaker_3D facebook com groups Polymaker T ...

Страница 16: ...www polymaker com www polymaker com ...

Отзывы: