Integrator’s Reference Manual for the VSX Series
4 - 58
cts
Sets or gets the CTS serial interface control signal (clear to send) configuration.
This command is only applicable if you have a V.35 network interface
connected to your system.
Syntax
cts <get|normal|inverted|ignore>
Feedback Examples
•
cts normal
•
cts inverted
Comments
The default setting for this signal is
“normal”
.
User interface screen location:
System > Admin Settings > Network > IP >
H.323 Settings> V.35/RS-449/RS-530
(page 3)
: CTS
Parameter
Description
get
Returns the current setting.
normal
Sets the signal to normal (high voltage is logic 1).
inverted
Sets the signal to inverted (low voltage is logic 1).
ignore
Ignores the signal.
Содержание VSX 7000s Series
Страница 169: ...System Commands 4 93 exit Ends the API command session Syntax exit ...
Страница 390: ...Integrator s Reference Manual for the VSX Series A 14 ...
Страница 400: ...Integrator s Reference Manual for the VSX Series C 2 ...
Страница 406: ...Integrator s Reference Manual for the VSX Series E 4 ...
Страница 410: ...Integrator s Reference Manual for the VSX Series F 4 ...