Polycom RealPresence® Practitioner Cart® 8000 User Manual p/n 1793149 Rev C 03/13 

 

 

Practitioner Cart POWER UP 

 

With the system completely turned off, press the 
Power button on the Control Keypad. 
 
 
 
 
The keypad LCD will light up, the controller will 
beep. 
 
All devices integrated into the Practitioner Cart will 
automatically turn on and boot up. 
 
If on-off switch is pressed, it will power off entire 
cart, even in battery mode. In combination with a 
low  speed of movement, continuous activation of 
moving switch, very low stopping distances- there 
is no need to have an additional emergency 
switch. 
 
MONITOR. 

a.  The power indicator will illuminate. 
b.  The generic logo will flash until a 

video signal is sent to the monitor 
input. 
 

NOTE:

  Initially the monitor may 

identify no signal until the HDX 8000 
boots up to a certain point. 

CAMERA 

a.  Initially the camera will spin from left 

to right, then to center. 

b.  The camera image is not displayed 

until the HDX 8000 is fully booted. 

HDX 8000 

a.  A blue light will illuminate.  NOTE:  

The Technology cabinet will have to 
be unlocked and opened to see light. 

b.  Initial Polycom splash screen will 

appear along with series of green 
LED lights.  This signifies that the 
HDX 8000 is booting up. 

  
Upon complete boot up, the display will show the 
HDX 8000 Home screen. 
 
As long as the data patch cord has been plugged 
into the custom I/O data plate, the Practitioner 
Cart will be fully operational, upon completion of 
initial setup (completed first time Practitioner Cart 
is turned on and set up).  

 

 
HDX 8000 HARDWARE AND 
ACCESORIES 

 

 

 
HDX 8000 

 

High definition Voice, Video & Content 

 

Flexible audio and video inputs/outputs 
 

 

Polycom EagleEye Camera 

 

True high definition image capture 

 

Enhanced image quality in all calls, not 
just HD 

 12x 

zoom 

 

180 degree panning radius 

 

Quick, sharp focus when using the 
manual pan/tilt/zoom or preset camera 
locations. 

 

 

 
Multi-Function Remote Control 

 

Controls features and functions of the 
HDX series systems 

 

Uses four (4) AAA batteries (included) 

 
 

 

Omni-directional HDX Microphone Array 

 

360 degree coverage 

 

22 kHz high fidelity audio 

 
 
 

PLACING, ANSWERING, AND 
ENDING CALLS 

 

To Answer an Incoming Call  

 

 

 

 

Содержание RealPresence Practitioner Cart 8000

Страница 1: ...d by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 Polycom RealPresence Practitioner Cart 8000 User Manual p n 1793149 Rev C 03 13 RealPresence Practitioner Cart 8000 Us...

Страница 2: ...min power cord size p 18 Update TOC Change transportation storage parameters Include operating parameters p 3 Add patient warning pp 3 and 12 Update images pp 5 6 7 8 Join split Service section p 17 C...

Страница 3: ...8000 Overview 4 General Features 4 Keypad Overview 6 Keyless Entry Operation 7 Manual Override Lock 7 Power Up 8 Polycom HDX 8000 Equipment and Accessories 8 Placing Answering and Ending a Call 9 Mult...

Страница 4: ...should not be exceeded DO NOT OPERATE the cart or any equipment installed on the cart while the cart is plugged in If the external power cord PROTECTIVE EARTH ground CONDUCTOR is broken or otherwise d...

Страница 5: ...ymbol Signal Word Level of Hazard IMPORTANT Indicates a situation that does not present any hazard but is very important in maintaining a well functioning cart ATTENTION Consult accompanying document...

Страница 6: ...adcasting medical procedures for education or telemonitoring Below is a pictoral overview of the major end items of the Polycom RealPresence Practitioner Cart 8000 1 Polycom Eagle Eye III HD Camera 2...

Страница 7: ...Allows top quality video for codec and Room Systems alike LCD Control Keypad Controls the drawer lock work light lift system and monitors the onboard power system Audio Sound Bar Sound bar has audio c...

Страница 8: ...art will not be plugged in or used for an extended period of time or the first time the cart is used Mute Button Press button to mute alarm when battery reaches 20 If battery reaches 10 mute will not...

Страница 9: ...nit The unit may auto lock with a drawer removed The drawer may be reinserted into a locked unit without unlocking the unit When a drawer is fully inserted into a locked telemedicine cart the newly in...

Страница 10: ...camera image is not displayed until the HDX 8000 is fully booted HDX 8000 a A blue light will illuminate NOTE The Technology cabinet will have to be unlocked and opened to see light b Initial Polycom...

Страница 11: ...specify that you are dialing IP or let the system auto detect the call type 8 Press the Call button to dial the call To Hang Up a Call Press the Hang Up button on the remote control If you are in a mu...

Страница 12: ...one at a time at any time during the call Press the Hang up button The disconnect screen will show you the sites connected into the call Press the number on the keypad 1 2 3 etc that corresponds with...

Страница 13: ...rrows and zoom button after being moved to a preset location This will not affect or change your preset assignments Displaying a Secondary Camera or DVD VCR If you have purchased a secondary camera or...

Страница 14: ...tor Viewing Press Display Picture In Picture button on the remote control twice The PIP window will open with a yellow border around it While this yellow border is on push the display button to move t...

Страница 15: ...t sharing Input S Video This is an S Video female Panel Mount connection This connection is designed to connect a document camera video camera or any peripheral that requires an S Video connection and...

Страница 16: ...ch for 2 seconds LONG TERM BATTERY STORAGE Greater than 2 Months WARNING If cart will not be used for more than 2 months turn off the cart by holding the on off button The battery will need to be rech...

Страница 17: ...r Terminal using terminal bolt A harmless spark may occur when connector touches terminal Quickly tap connector to terminal to diminish effect b Cover terminal bolt with protective red boot c Fasten B...

Страница 18: ...g the power cord into a wall outlet When cleaning the cart wipe cleaners off of surface with a damp cloth and thoroughly dry Never cover the cart or its components in liquid or allow liquids to flow i...

Страница 19: ...arm will sound The alarm may be muted for 1 minute Until the cart is plugged in to charge the audible alarm will continue to sound every minute If alarm fails to shut off after plugging in cart for se...

Страница 20: ...devices being used a trained and qualified medical professional healthcare provider working within the scope of their license should facilitate and assist patients with use of the Polycom Practitione...

Страница 21: ...resence Practitioner Cart 8000 Manufactured by Rubbermaid Healthcare 16905 Northcross Drive Suite 200 Huntersville NC 28078 Polycom RealPresence Practitioner Cart 8000 User Manual p n 1793149 Rev C 03...

Отзывы: