Chapter 1-Hardware Description
Polycom, Inc.
1-35
3
Use the metal ejector levers to pull the RTM IP card out of its slot in the backplane.
4
Carefully slide the RTM IP card out through the rear panel.
5
On the card to be installed, move the ejector levers to their fully open position.
6
Slide in the replacement RTM IP card.
7
Push the RTM IP card firmly into the backplane, making sure it is properly seated in its
slots.
8
Ensure that the metal ejector levers are fully retracted into their housings.
9
Tighten the captive screws on the rear panel of the RMX 2000 that secure the RTM IP
card.
10
Turn ON the RMX 2000.
Removing the Blank Cover from the Rear Panel
Use the following procedure to remove the blank cover:
1
Ensure that the power switch/circuit switch on the RMX is turned OFF (O).
2
Unscrew the captive screws on the rear panel of the RMX that secure the blank panel.
3
Use the metal ejector levers to pull the blank panel.
For more information on the
Card Configuration Modes
after reset, see "
MPMx, MPM+ and MPM
Modes”
on page
1-21
.