Page 4
2)
Connect the pre-tested
cable to the touchpad.
3)
When power is applied,
the LCD screen on the
touchpad should show
clock time and the
temperature where the
touchpad is located.
Otherwise, check the
power supply and the
cable.
4)
Turn off the power and disconnect the
touchpad. Position the touchpad at the right
place. Ideally, its position is approximately
1.6M off the
floor
on the wall. Fit the cable
through the wall cavity and connect the
touchpad again.
Please note that the touchpad should not be exposed
to directs sunlight and other heat sources.
5)
Mount the supply air sensor in the supply air
duct upstream from the motorised dampers.
Fit the sensor cable through the wall cavity
and plug into the socket on the back of the
touchpad.
6)
Connect the battery by plugging into the socket
on the back of the touchpad.
7)
Mount the touchpad onto the bracket in the wall
cavity. Connect the cable to the 24VAC power
supply. The LCD should show clock time and
temperature.