Setting Up the Poly Medialign Dual Display System
72
f
Attach two wall mount brackets to the lower rail of the upper horizontal frame of the right frame
assembly using two M6 × 12 mm screws per bracket.
g
Locate the right frame assembly on the right horizontal support rail. The distance between the
frames is 38 mm (1.5 in.). Move the frame close to the wall so that the vertical rails are
approximately 5 cm (2 in.) away from the wall. Check for plumb and level, adjusting the leveling
feet and the distance of the V-rails from the wall as required. Be sure to level between the two
frame assemblies as well.
(2) WALL MOUNT BRACKET
1342-85958-001
(4) M6 × 12 mm SCREW
1601-68586-001
Содержание Medialign 65
Страница 2: ...2...
Страница 7: ...Installation Overview 7 Poly Medialign 65 system with single 65 display...