25
PARVIS SL SMA
POLITEC | INSTALLATION MANUAL - VER.3.0
17.Technical specifications
OUTDOOR RANGE
0-50 m
INDOOR RANGE
0-100 m
SYNCHRONISATION
Optical
OPTICAL SENSORS
Double optics with pulsed beams 950 nm
TOTAL BEAMS
2 to 6 parallel (TX / RX / TX + RX)
POWER SUPPLY
230 Vac + 3.6 V 1.8 Ah battery Rechargeable by integrated
solar panel
AUTONOMY
2-3 months in the absence of recharge
OPERATING TEMPERATURE
- 10
°
C / + 70
°
C. Power heaters for temperatures down to -
25
°
C.
ALIGNMENT ANGLE
20
°
Vertical - 180
°
horizontal
DETECTION SYSTEM
OR / AND 1st and 2nd Beam / AND Random
REMOTE CONTROL
AND Random
ALARM OUTPUT
NC relay contact
DISQUALIFICATION OUTPUT
Automatic, if enabled, with external signalling,
O.C.: NO to GND
ANTIMASK OUTPUT
Automatic, if enabled, with external signalling, O.C.:NO to
GND
BARRIER TAMPERING OUTPUT
Tamper on columns with NC relay contact on RX board,
the TX Tamper optically transmitted on RX after 30
seconds
LOW BATTERY
Buzzer acoustic signalling on alarm and signalling to the
outside, O.C.:NO to GND
EXTERNAL SCREEN
Infrared with UV filter
PROFILE
DIMENSIONS ΦxH
Tube diameter 80mm x from 1200mm to 3000mm
on a 300mm round base
INGRESS PROTECTION RATING
IP 54 or 65 on request
WARRANTY
2 YEARS
18.FAQ
I can't align
Check that there are no obstacles of any kind interposed
between RX and TX and that the conditions of the site do
not represent an impediment.
N.B. remember to reactivate the optics once the
alignment operation is finished.
Make sure that the TX is in the test phase (orange LED of
the optic in question ON and the others OFF).
Make sure that the connectors are well inserted and that
the DIP configuration is correct;
Make sure there are no external light sources that
interfere with the correct reading of the signal (gate
photocells, other barriers, infrared etc.).