![Politec Parvis Solar SMA Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/politec/parvis-solar-sma/parvis-solar-sma_installation-and-mounting-manual_1574067024.webp)
24
PARVIS SL SMA
POLITEC | INSTALLATION MANUAL - VER.3.0
16.Insulating resin for electrical connections
ONLY INSULATE THE COLUMN AFTER CARRYING OUT ALL THE ELECTRICAL CONNECTIONS INSIDE THE
COLUMN AND CARRYING OUT SYSTEM TESTING.
CHARACTERISTICS:
insulating resin for electrical connections; prevents the infiltration of water and
humidity.Use two-component resin to seal the column and increase the IP protection to IP65,
obviously this is possible only if the cover with the cable glands at the base of the column has been
used correctly (see step 3 below and paragraph 7 on page 9).
The resin can however be removed for repair and then repositioned.
1
Pour the contents of bottle B into A.
2
Close the cap and shake vigorously for
about 1 minute.
3
Pour the obtained resin into the cavity,
as shown in the images.
4
The mixture becomes a gel in a few
minutes and solidifies completely in 4
hours at 25°C, the time will be shorter if
the temperature is lower.