1. Password Management 

Password Enter: 

1) Press"SELECT" key, the panel shows "12345". 
2) Press"SETUP" key, the panel display as "1-345", "_" is a modify command to set 
number, press the "SETUP" key, "_" can be recycled to the right. 
3) Press "SELECT" key, as plus key when setting the password number with "_" . 
4)  After  entering  the  correct  password,  press"ENTER"key.If  display  as"00000", 
means the password is set up; If display as "E0000", means the password is wrong, 
need press "ENTER" key to re-enter the correct password. 
5) Then press "ENTER" key, display as "d-01", then press "SELECT" key to enter the 
next step. 

Password Change: 

 Press"SELECT" key when display as "12345", if changed the password, enter your 

password. Steps please refer to details of Password Enter above. 

 If forget password, press"SETUP" → "SELECT" to change "E0000" into "88888" 

then  press"ENTER",  and  display  as  "00000",  press  "SELECT"  to  enter  the  number, 
press"SETUP" to change next number 
6) Enter the password to be set, press "ENTER" key, there will be"A-6" for 6-zones, 
"A-18" for 18-zones, "A-33" for 33-zones, press"ENTER" key, then the password is 
set up. 
7)  If  forget  password,  long  press"ENTER"  can  restore  to  the  initial  password 
"123456".   
 

2. Zones Distinction: 

1) 

6-zones:

 from bottom to the top is 1~6 zone evenly distributed. 

 1~6 zone sensitivity, the sensitivity is proportional to its numeric. 

 "H" is overall sensitivity, the sensitivity is proportional to its numeric. 

2) 

18-zones and 33-zones:

 from bottom to top is 1~18/1~33 zone evenly distributed. 

 1~18/1~33 zone sensitivity, the sensitivity is proportional to its numeric. 

 "H-xxx" is overall sensitivity, the sensitivity is proportional to its numeric. 

 

OPTIONAL FUNCTIONS

 

PC Networking, Turnstile Integration, UPS, Camera, etc.

 

 

 

 

 

Содержание SmartGuard E-6006

Страница 1: ...Electronics and Computer Industry Inc Atat rk Organized Industrial Zone 10024 St No 9 Cigli Izmir TURKEY Tel 90 232 328 1645 pbx Fax 90 232 328 1674 Whatsapp 90 532 498 3402 www smartguard com tr www...

Страница 2: ...MENT 3 PERFORMANCE AND FEATURES 4 PARTS 5 INSTALLATION 6 CONTROL PANEL 7 DETECTION ZONES 7 OPERATION 8 PASSWORD MANAGEMENT 13 OPTIONAL FUNCTIONS 13 DETECTION ADJUSTMENT 14 FAQ 15 TECHNICAL PARAMETERS...

Страница 3: ...ill have a 1 minute self inspection after power on to achieve the excellent performance 5 The passers must abide by the predefined standby time and alarm time 1 s when checking walking through one by...

Страница 4: ...nd display the alarm zone at once if the metal size in human body is more than the predefined metal parameter of weight quantity or shape so that security staff can find the person with prohibited met...

Страница 5: ...ference sources and electromagnetic radiation source are not allowed to close the device the recommended distance is 1 2 meters The parameters of the distance are determined by the installation enviro...

Страница 6: ...clude the coins keys jewelry belt buckle etc Digital Pulse Technology Digital Signal Processing DSP and filtering system has excellent anti interference ability Password Protection only the correct pa...

Страница 7: ...5 PARTS 1 Door Panel 2 Crossbar 3 Integrated Host 4 Alarm zone LED 5 Infrared Sensors 6 Waterproof Foot Cover 7 Power Line Signal line Interface...

Страница 8: ...e main box respectively with bolts and nuts locked tightly 3 Make sure the door probe line on the left and right were tightly inserted into the corresponding socket on the motherboard pay attention to...

Страница 9: ...of passer and alarm Standby Indication indicator in red when alarming B LED bar Alarm As Figure 1 there are six sets of unique pinpointing LEDs which represent six detection zones from bottom to top 1...

Страница 10: ...djust the Frequency Press ENTER confirm the selection In order to avoid signal interference the frequency code of each adjacent device must be different For user convenient operation we have particula...

Страница 11: ...will show H xxx means device whole Sensitivity Level is xxx 10 After Zone Sensitivity Level finish adjustment press SELECT will show AP means entered Application Mode adjustment option Press ENTER to...

Страница 12: ...setting 5 One more time press ENTER will show A 18 means the device of 18 zones 6 Press SETUP will show d 01 which is alarm duration time 01 means alarm duration of 1 second maximum alarm duration of...

Страница 13: ...ready to work 14 The device will automatically display PASS COUNT ALARM COUNT the number of memories is 99999 press RESET can recount 33 Zone Walk Through Metal Detector 1 Long press SELECT 3 seconds...

Страница 14: ...pectively 9 Now Left Right side Zone Sensitivity Level finish adjusting press SELECT entering whole Sensitivity Level adjustment will show H xxx means Device whole Sensitivity Level is xxx 10 After al...

Страница 15: ...above If forget password press SETUP SELECT to change E0000 into 88888 then press ENTER and display as 00000 press SELECT to enter the number press SETUP to change next number 6 Enter the password to...

Страница 16: ...evel then let test person take the sample pass by the walk through metal detector and there will be alarming 3 Appropriately lower the sensitivity then take the sample pass by the walk through metal d...

Страница 17: ...shaking If there s wind suggest customer take wind protection measures or replace the installation location 2 After installed the walk through metal detector there is frequently false alarm while test...

Страница 18: ...Working Voltage 100 240VAC Power Frequency 50 60Hz Power Consumption 20W Working Temperature 10 45 Dimension MM External Height 2200 External Width 850 Internal Height 2000 Internal Width Standard 71...

Страница 19: ...cond Sensitivity 1 18 detection zones 99 Menu Password 12345 33 Zones Walk Through Metal Detector Product Name Walk Through Metal Detector Alarming Time 1 second Sensitivity 1 33 detection zones 99 Me...

Страница 20: ...nty card will regard as invalid While purchasing please confirm the warranty card and receipt and make sure all information filled are correct and detailed and send to us for better services 4 If card...

Отзывы: