65
Blades don’t Open
Typical causes:
•
Shutter not seated
•
SOL 1 not adjusted properly
•
Wire connectors not connected to SOL 1 or SOL 2
•
Kicker spring not seated
•
Solenoid not seated straight
•
Sticky blades
•
No SOL 1 drive
•
Drive link not seated to walking beam
•
Encoder wire hitting SOL 2 plunger
•
Base block Quintic post distorted
•
SOL 2 plunger sticky
•
Wireform switch not in correct position
•
Broken drive link
•
Catch pawl hang-up
•
Photodiode not glued properly
•
SOL 2 moves in frame
•
Encoder lead broken
•
Counter wheel hang up
•
Door latch distorted
•
Black and red wires not seated to Strobe Board (J14-J15)
•
Poor LCD module connection (See Poor LCD Module Connection, Page 4-9)
No S1 Cycle
Typical causes:
•
S1/S10 switch distorted
•
Wire connectors not seated to RM, FM, Strobe or motor flex
•
Defective Strobe
•
Poor LCD Module connection (See Poor LCD Module Connection, Page 4-9)
•
LCD module defective
Sticky S1/S10
Typical causes:
•
Button hung up on top cover insert
•
S1/S10 button bezel not seated