Test Procedure
1. Push the Reset button on the Tester, then depress the Shutter Button. Disregard the
meter reading (this sets up Tester circuitry).
2. Press the Shutter Button again and watch the Timing Meter carefully. Note the
reading that remains constant for two seconds. Compare this reading to the
Specification.
3. If the reading is not within spec, adjust the blade speed (page 3-30) and retest the
camera.
4. If the adjustment did not bring the Blade Speed within specification, repair or replace
the Shutter Assembly and retest.
5. If Blade Speed is now within specification but Strobe Exposure is still out of spec,
replace the Exposure Flex and retest.
Spectra Pro/Image Pro/Minolta Pro Star Tester Specifications
Covered Ambient:
-.1- to +.30 stops
(Install Test Cover on
camera for test purposes)
Covered Strobe Exposure
-.30 to +.2- stops
(Graywall):
The following additional tests are required only if the Strobe Exposure (Graywall) cannot
be corrected by adjusting the IR exposure calibration slide. See page 3-14 of the
Spectra Camera Service Manual.
ZLS Graywall:
230 ZLS to 350 ZLS
Hybrid:
(60 ZLS to 110 ZLS)
Blade Speed:
20 to 24 ms
Содержание Spectra/Image One Board
Страница 35: ...35 Figure 3 7 Star tester 12650 3 controls and indicators see text for descriptions...
Страница 38: ...38 Figure 3 10 Positioning camera on horn against star tester Guide Tab...
Страница 75: ...75 Figure 4 5 Spectra pro image pro minolta pro system schematic...
Страница 76: ...76 Figure 4 6 One board strobe exposure module schematic...
Страница 77: ...77 Figure 4 7 Ranging board schematic...
Страница 78: ...78 Figure 4 8 Features module and display module schematic...