M402b MiniPortrait Camera Repair Manual
Disassembly/Assembly
22
Shutter Actuator
(Figure 2-8)
Removal
1. Remove the front cover assembly (Figure 2-1).
2. Using a pair of small needle nose pliers, gently remove the clip and washer that
secure the shutter actuator return spring and the shutter actuator to the right shutter
actuator guide.
Note:
While removing the shutter actuator be careful not to misalign
the shutter and the diaphragm plates.
If the shutter and the diaphragm plates are misaligned during the
removal of the shutter actuator, refer to the Shutter and Diaphragm
Plate assembly/disassembly procedure to properly realign (see page 24).
3. Remove the shutter actuator from the right shutter actuator guide being careful not to
misalign the shutter and the diaphragm plates.
Figure 2-8. Replacing shutter actuator
Camera Body
Left Shutter
Cocking Guide
Shutter Actuator
Shutter Plate
Assembly
Right Shutter
Cocking Guide
Shutter Actuator
Return Spring