M402b MiniPortrait Camera Repair Manual
Disassembly/Assembly
18
X-Sync Connector/X-Sync Switch
(Figure 2-6)
Removal
1. Remove the front cover assembly (Figure 2-1).
2. To remove the X-sync connector:
•
Using a soldering iron and a solder sucker, remove the wires from the X-sync
connector.
•
Using a Phillips head screw driver, remove the two (2) screws that secure the
X-sync connector to the front cover. Lift off the X-sync connector.
3. To remove the X-sync switch:
•
Using a soldering iron and a solder sucker, remove the orange and black wires from
the X-sync switch.
•
Using a Phillips head screw driver, remove the two (2) screws that secure the X-sync
switch to the front cover. Lift off the X-sync switch.
Figure 2-6. Replacing x-sync connector/x-sync switch
Rear View of Front Cover
X-Sync Connector
X-Sync Switch
Orange
Wire
Black Wires
Red Wire
Front Cover