EMERGENCY DISCONNECT
CAUTION: The gate will move freely and uncontrolled
when the gate operator is removed from the gate. ONLY
disconnect the gate operator when the control box power
switch is OFF and the gate is NOT moving.
Step 1
Turn control box power switch to the OFF position.
Figure 33
Bushing
Clevis pin clip
Clevis pin
EMERGENCY DISCONNECT
Step 2
Remove clevis pin clip and clevis pin from the front and
rear mounting points.
Step 3
Remove the gate operator from the mount.
NOTE: The gate can be opened and closed manually when
the gate operator is disconnected.
Warning:
Do not allow operator to hang freely when
disconnected from the gate. This can cause damage to the
operator and will void the warranty.