Do not interrupt gate movement (full opening/closing). In the even of the gate movement being interrupted, learning will 

be resumed automatically during the next opening.

 

If the status light 

 flashes, resume the automatic wing movement path learning procedure (4 full opening and closing movements). 

If the status light 

 

keep flashing, see “Diagnostics”, page 49.

 

If the gate opens again after the closing movement is finished, loosen the wing fixtures and move them slightly towards the centre of the 
gate.

 

 

After finishing the installation it is obligatory to check whether the obstacle detection system complies with the 

specification provided in Annex A to the EN 12453 standard.

 

Setting the electronic control system standby/wake-up mode

 

 

After performing automatic learning, the electronic system switches automatically to standby mode after 5 minutes 

if it receives no commands, in order to save power. In the standby mode all the status lights are off.

 

In order to check whether the driver is powered, or to check/change the setting, it is necessary to press and hold the 

 button for 2 

seconds in order to wake the electronic system. The electronic system switches to standby mode automatically after 5 minutes  if it 
receives no commands. 

Full gate closing and opening

 

The remote control devices delivered in the set are programmed. The procedure below enables programming 

additional remote control devices.

 

Button No. 1

 

Содержание EASY WAY PACK 201

Страница 1: ...Manual EASYWAYPACK 201 AUTOMATIC GATE INTELLIGATE smart gate ...

Страница 2: ... set includes a connector compatible with various models Depending on the system 8 sets The carriage bolt is intended for installing the gate on 70 x 70 mm steel posts in the event of installing the gate on 100 x 100 mm steel posts it is necessary to obtain 8 sets of M8 x 120 mm carriage bolts and for 120 x 120 mm steel posts it is necessary to obtain 8 sets of M8 x 140 mm carriage bolts 2 sets 4 ...

Страница 3: ...Depending on the model purchased the appropriate connector should be included in the set INTELLIGATE SMART GATE 8 sets 2 sets 4 sets The carriage bolt is intended for installing the gate on 70 x 70 mm steel posts in the event of installing the gate on 100 x 100 mm steel posts it is necessary to obtain 8 sets of M8 x 120 mm carriage bolts and for 120 x 120 mm steel posts it is necessary to obtain 8...

Страница 4: ......

Страница 5: ...peration modes of remote control devices 33 Turning on the power supply for the system 34 Automatic learning of the gate travel path 34 Setting the electronic control system standby wake up mode 35 Full gate closing and opening 35 Obstacle detection 36 EASY WAY PACK 5 User training 36 Advanced settings 36 Opening that enables passage of pedestrians 36 Automatic closing 38 Remote control programmin...

Страница 6: ...is to supply the market with product that meet the highest standards of execution and the high expectations of customers in terms of aesthetics and the prevalent fashion on the fencing market Thank you for your trust and choosing the EASY WAY PACK 201 device and Intelligate We would like to ask you to become thoroughly familiar with this manual prior to commencing installation TECHNICAL SUPPORT HO...

Страница 7: ...mmobile elements located nearby in view of the danger related to movement of the driven part during opening crushing shearing seizing Monitor the gate visually while it moves All the switches without a lock have to be located at a place from which the driven part will be directly visible but in appropriate distance from moving elements They have to be installed at the height of at least 1 5m at a ...

Страница 8: ... battery if it was installed should be removed from the drive assembly prior to handing it over for disposal Do not discard the drained single use batteries of remote control devices or the battery if any is installed together with household waste They have to be handed over to a special waste collection point for recycling Do not discard the decommissioned drive assembly together with household w...

Страница 9: ...Shearing and crushing risk to hands Solution If the system features a shearing zone leave a spacing of at least 10 cm between the wing and the post wall bevel the corner without weakening its structure applies to concrete posts ZONE 3 Risk of impact Solution System for detection of obstacles within the drive ZONE 4 Risk of trapping and crushing Solution System for detection of obstacles within the...

Страница 10: ...e 90 range Automatic detection of obstacles In line with the EN 12453 standard Annex A Operating temperature from 20 C to 60 C Thermal sheath Yes Protection class IP 44 Built in radio receiver Yes Remote control devices Radio frequency 433 42 MHz Range of use 30 m Number of memory settings 16 Connections possible Orange light output flashing 24 V 10 W Zone lighting output powered terminal max 500 ...

Страница 11: ...ters built into the drive Wing dimensions and maximum weight The width of each wing should be between 1 m and L Maximum opening angle for the hinges installed on the side of the post for standard hinges Dimensions of drives and control module in mm Built in opening limiter The limiter enables setting the maximum gate opening angle without having to use limiters in the ground ...

Страница 12: ... required in order to ensure correct seating and fixing of the corner Bottom lock Set the limiters at the gate opening angle desired The angle should be within the range of 85 95 The opening angle should be the same for both the gate wings In the event of setting an angle of over 95 degrees there is a risk of abnormal operation or damage to the electronics or hinges Middle rail Fixing bracket Post...

Страница 13: ...p distribution box socket wrench 13 and 10 pincers wire stripping pliers hammer drill flat screwdriver cross screwdriver flat wrench 13 flat wrench 17 spirit level tape measure pencil cutter Tools required ...

Страница 14: ...on smaller than indicated in the manual may lead to voltage dips that may cause incorrect functioning of motors 1 Power supply leading 3 x 1 5mm2 cables for outdoor use 2 24V connection between two drives 2 x 1 mm2 3 Connection between photocells 2 x 0 75 mm2 Powering from mains In order to ensure the functioning of the gate opening mechanism it is necessary to connect 230 V 50 Hz power supply to ...

Страница 15: ...70 POST NOTE View from above 8 SETS LEFT POST RIGHT POST LEFT CONNECTOR RIGHT CONNECTOR In the case No it is necessary to obtain 8 complete sets of M8 x 120 mm carriage bolts at the 100x100 mm steel posts NOTE View from the property side 100x100 POST 100x100 POST 8 SETS LEFT POST LEFT CONNECTOR RIGHT CONNECTOR RIGHT POST NOTE View from above ...

Страница 16: ...the case No it is necessary to obtain 8 sets of steel dowels or dowel pins at the concrete posts depending on the material of which the post is made or 8 SETS or 8 SETS or NOTE View from the property side 120x120 POST 120x120 POST 8 SETS LEFT POST LEFT CONNECTOR RIGHT CONNECTOR RIGHT POST NOTE View from above or ...

Страница 17: ... of the automatics Mandrel ejected to the maximum 3 The set prepared should be applied to the previous levelled closed gate The automatics should not rub against the fixture to the gate View from the property side 70x70 POST 100x100 POST 120x120 POST depending on the post size CONCRETE POST WITH A RECESS CONCRETE POST WITHOUT A RECESS ...

Страница 18: ...hich kind of fixture is present in you gate Profile without openings Profile with factory made through openings Profile with threaded openings Reinforced profile with openings Profile with longitudinal openings ...

Страница 19: ...ter in the ground View from the property side or Mark the points for drilling Mark the points for drilling After applying the automatics to the gate marker the points and drill the openings leaving the option of further adjustment Drill the opening in the axis of longitudinal openings using an 8 5 mm drill bit Ream the openings using a 10 5 mm drill bit from the external side of the gate ...

Страница 20: ...d in such a way as to enable further adjustment by means of gentle movements tighten the bolts so that slight resistance can be felt 7 Then when the gate is closed fix the connector to the post 8 Install the automatic device onto the properly installed fixtures View from the property side ...

Страница 21: ...the opening location drill the gate middle rail through with a drill bit Next from the side of the street ream the opening made with a drill bit Install an M6 carriage bolt having the length appropriate for the gate type choose one opening of the three that does not interfere with the picket and drill the gate middle rail through M6 with length adjusted to the gate type ...

Страница 22: ...g two chosen openings openings in the gate fixing into 2 longitudinal openings fixing into 2 longitudinal openings View from the property side The actuator mandrel is ejected to the maximum towards the internal limiter when the closed gate adheres to the limiter in the ground 11 Hold the position of the L and R connectors using a clamp Gate type No 12 Repeat the steps 6 10 ...

Страница 23: ...bolts View from the property side The actuator mandrel is ejected to the maximum towards the internal limiter when the closed gate adheres to the limiter in the ground 13 Hold the position of the L and R connectors using a clamp Gate type No ...

Страница 24: ...perty side Dismantle the picket reinforcement Insert M8x16 carriage bolts into openings then screw in the connector using M8 nuts and tighten the picket reinforcement 16 Repeat the steps 8 and 9 17 Remove the automatics Select one opening on the fixture that does not interfere with the picket Screw in a sheet metal screw there Choose one of the three which does not interfere with the picket and sc...

Страница 25: ...e Spread the bolts and install the spacer and the gate connector Use washers and M8 nuts for tightening the connector View from the property side The actuator mandrel is ejected to the maximum towards the internal limiter when the closed gate adheres to the limiter in the ground 18 Hold the position of the L and R connectors using a clamp Gate type No ...

Страница 26: ... unlocking element properly it is necessary to maintain the installation direction specified on the diagram Do not install the bolt from the underneath 21 Install the drive mandrel in the clamp fixing the V1 or V2 wing Fix the unlocking element D to the drive mandrel in order to lock the mandrel 22 Repeat the appropriate installation steps on the other wing ...

Страница 27: ...ng limiters in such a manner that their bolt is in contract with the ball nut of the actuator and then tighten them using a hexagonal 3mm Allen wrench 2 bolts per limiter Make 2 turns with the wrench after achieving the contact point Push the button No 1 of the remote control device The second wing of the gate will open Push again the button No 1 of the remote control device in order to stop the g...

Страница 28: ... antenna Connection to the mains power supply or solar plant power supply Placement of the electrical distribution board on a post The box should be installed on the side of the power supply source View from the property side Installation of the control module Placement of the electrical distribution board on a post The box should be installed on the side of the power supply source ...

Страница 29: ...le to the post 3 Place the angle bar fixing the module near the post wall Checking whether it is level by placing the spirit level at a right place Mark the angle bar fixing points 4 Remove the angle bar and drill an opening through the post wall Determine the diameter of the opening on the basis of the type of bolts used for fixing Fix the angle bar to the post wall 5 Place the bottom of the modu...

Страница 30: ...he post wall 1 bolt for fixing the module to the angle bar 2 bolts for fixing the module to the post wall Checking the antenna location 8 The correct location of the antenna is of fundamental importance for optimal functioning Antenna Never trim the antenna wire Connection of drives The M1 drive starts the wing that opens first and closes last opens in order to enable a pedestrian to go through th...

Страница 31: ...ct the drives in the manner indicated in the table below Connect the cable of the drive No to the terminal No M1 blue 10 brown 11 M2 blue 12 brown 13 Connection to the power grid Due to safety reasons these activities have to be performed with the power supply disconnected Use a 3 x 1 5 mm2 cable for indoor use at least of the H07RN F type It is obligatory to use the cable holder provided Check wh...

Страница 32: ...inals No 16 and 17 red 230 V label Install a connection block on the earthing cable yellow green and place it in the control module Phase Neutral It is obligatory to adhere to the recommendations regarding cable colours Install a connection block on the earthing cable yellow green and place it in the control module Close the control module housing 4 Place the information sticker on the bottom of t...

Страница 33: ...tomatic system Switching from automatic mode to sequential mode Confirmation of settings Long press for more than 0 5 second The status light flashes Short press for less than 0 5 second The status light is on continuously Operation modes of remote control devices Before starting to enter the installation parameters it is necessary to check whether the ON OFF and PROG status lights are on and whet...

Страница 34: ... The status light flashes 2 times The drive is live and awaits automatic learning If the status light does not light up or if the number of flashes differs from the expected one see Diagnostics Automatic learning of the gate travel path Check whether the system is live the status light flashes 2 times 1 Push the button No 1 of the remote control device in order to make the gate open FULLY The wing...

Страница 35: ...ith the specification provided in Annex A to the EN 12453 standard Setting the electronic control system standby wake up mode After performing automatic learning the electronic system switches automatically to standby mode after 5 minutes if it receives no commands in order to save power In the standby mode all the status lights are off In order to check whether the driver is powered or to check c...

Страница 36: ...stops When closing the gate the gate stops and the opens again User training It is necessary to familiarise all the users with the principles of fully safe operation of this gate with an electric drive standard usage and unlocking method and carrying out obligatory periodic checks Advanced settings Opening that enables passage of pedestrians Functioning of the opening mode that enables passage of ...

Страница 37: ...ton No 2 of the remote control device The RADIO and status lights become lit and then they go out The function of opening that enables passage of pedestrians becomes activated in this button Move away from the electronic control system in order to test the mode of opening that enables passage of pedestrians Deactivation of the opening mode that enables passage of pedestrians Repeat the procedure A...

Страница 38: ...of the drive 1 Press and hold for 2 s the button of the electronic control system The status light becomes lit 2 Put the remote control device on the dial of the electronic control system 3 Hold the pressed button No 1 of the remote control device until the status light starts flashing After finishing step 3 the next steps can be performed in remote mode without placing the remote control device o...

Страница 39: ...l device on the dial of the electronic control system 3 Hold the pressed button No 1 of the remote control device until the status light starts flashing 4 Push the button No 2 of the remote control device The status light flashes 5 Push the button No 1 of the remote control device twice 6 The status light is off The automatic closing function is activated ...

Страница 40: ...that enables passage of pedestrians in the button No 1 of the remote control devices Methods of programming a remote control device with 2 buttons Button 1 Button 2 Method 1 Full opening Opening that enables passage of pedestrians or other Somfy RTS automatic mechanism Method 2 Other Somfy RTS equipment Full opening Button 1 Button 2 Button 3 Button 4 Method 1 Full opening Opening that enables pas...

Страница 41: ...s lit 2 Put the remote control device on the dial of the electronic control system 3 Press shortly the remote control device button intended for programming The RADIO status light becomes lit and then it goes out once the remote control device button is released In that button the full opening mode has been programmed Remote control device with 3 buttons 1 Press and hold for 2 s the button of the ...

Страница 42: ...changing the movement direction of the gate in the event of detecting an obstacle It is possible to install a set of photocells Each set of photocells includes a transmitting photocell TX a receiving photocell RX Placement of photocells In order to facilitate the installation cables located the receiving photocell on a post featuring the drive fitted with an electronic system Before connecting the...

Страница 43: ...shed Operation with the use of photocells if the photocells are obscured when the gate is being closed the gate stops and then starts opening again In case of removal of photocells After removing photocells turn on the drive power supply again and then carry out the Deactivation of automatic closing procedure page 39 Orange light option Lamp 10 W and 24 V MAXIMUM Using a lamp with power of more th...

Страница 44: ...y electrical malfunction The batter is built into the drive s electronic module and directly connected with it Operation time 10 cycles in continuous mode or 24 hours if the gate is in good technical condition Optimal battery charging time prior to use 48 hours Battery lifetime 3 years In order to ensure optimal lifetime of the battery disconnect the electrical power supply of the gate 3 times a y...

Страница 45: ... the post and check whether it is not obscured The antenna is connected to terminals 1 and 2 blue ANT sticker of the control module the cable core goes to terminal 1 while the ground wire bundle to terminal 2 Video intercom option This element is not compatible with solar energy powering Connect only one potential free contact without power supply ...

Страница 46: ...the drive is started It goes out automatically after 1 minute and 30 seconds after the movement ends Powering with solar energy option Never connect the drive to 230 V power supply when it is connected to the solar power supply source as it may lead to damage to the electronic module of the drive When the driver operates using a solar power supply the gate can be controlled only using remote contr...

Страница 47: ...elp in removal of malfunctions The battery lifetime is usually 2 years If the defect is still present if another problem appears or if you have any questions regarding the driver assembly visit our website www polargos pl Remove the latch of the remote control device Insert a screwdriver in the gap and raise the cover Remove the battery using the screwdriver Replace the battery 3 V CR 2430 During ...

Страница 48: ...ET status light is lit 6 In order to delete the settings of the remote control devices control points stored in the memory Hold the pressed button No 2 of the remote control device until all the status lights are lit 7 The status light flashes twice see Automatic learning of the gate travel path page 34 Locking unlocking of drives After the drives are unlocked the gate can be moved manually in the...

Страница 49: ...ng Launch the automatic learning of the gate travel path see page 34 3 flashes Damaged photocells Make sure there is no obstacles between photocells Check the photocell settings Check the photocell cables see pages 14 42 43 If the photocells have been disconnected on purpose perform the Deactivation of automatic closing procedure page 39 4 flashes The START control of the electronic module is acti...

Страница 50: ...es Opening of a gate and garage door turning off the alarm and turning on the lighting prior to returning home Automatic closing after parking the vehicle Opening and closing of all the devices owned with a single touch The most important functions Smart gate controlled by means of mobile devices RTS gate RTS garage door RTS connected lock RTS Alarm RTS Lighting RTS Sockets Philips Hue lamp SMART ...

Страница 51: ...the Intelligate smart gate check whether the remote control devices are programmed correctly see pages 40 41 Also check whether the Easy Way 201i gate learned the gate travel path correctly see pages 34 35 Prior to the installation familiarise yourself with the Safety Manual included in the INTELLIGATE automatic gate set 2 Connect the control device to the power supply and the Internet at home SMA...

Страница 52: ...ected properly using an Ethernet cable green LED status light The LED status light indicates the unit status and the operations carried out 1 Launch 2 Connection status Problem with online connection Online connection is available 13 sec 10 sec Stage 1 Select your country and language in the activate the controller field Stage 2 Press the Connexoon item SMART GATE ...

Страница 53: ...onal data Stages of activation of Connexoon Access RTS Stage 3 Enter the PIN code of your Connexoon controller The individual code is located on the bottom of the controlling device Stage 4 If the selection window appears choose the Connexoon Access RTS SMART GATE ...

Страница 54: ...e 8 Confirm Activation of the Connexoon controller reception of the confirmation e mail Stage 9 You will receive a confirmation e mail In order to complete the activation of the Connexoon controller click the Click here link SMART GATE ...

Страница 55: ...obile phone Enter the e mail address and password that you specified during activation of the Connexoon controller see page 53 Activation screen Specify your identifier The identifier enables checking which activities have been performed using the mobile phone You can change the identifier at any time in the parameters page of the menu available in the history SMART GATE ...

Страница 56: ...s in line with the guidelines below 1 Accept the statement 2 Click the question mark Click here Click here Click here 3 Press the TEST button in order to check the correctness of connection between the device and the gate Then click on NEXT 4 Mark SGS 201 400 501 601 S C 5 with a dot SMART GATE ...

Страница 57: ...name form Unknown component to your own e g Intelligate 6 Click on SAVE Operation of the CONNEXOON ACCESS RTS control device Menu Mode editor Devices registered in Connexoon Weather Own modes 1 Interface SMART GATE ...

Страница 58: ...ed using a single button press E g When I come back after a single press of the button the gate opens the external lighting turns on and the garage door opens Click the icon and select the gate position open close and then press 2 Control over devices You can control a gate garage door lighting etc in the grey frame located at the bottom of the interface Press the icon of the device that you want ...

Страница 59: ...utton press In order to adjust then open all close all mode to your own need press the button Next press the symbol of the icon in order to adjust the open all mode to your needs or the symbol of the icon in order to adjust the close all mode to your needs Mark the devices for which actions should be performed and the confirm this by pressing OK SMART GATE ...

Страница 60: ...es to be performed Mark the devices for which actions should be performed a few minutes after leaving In order to adjust then Leaving mode to your own need press the symbol of the icon Leaving When leaving home you can open the gate with one press of a button and it will close automatically after a time that you specified SMART GATE ...

Страница 61: ...me welcomes me in the manner that I specified In order to adjust then Returning mode to your own need press the symbol of the icon Specify the distance at which you want the Returning mode to be activated and turn the geolocation on or off Mark the devices for which actions should be performed prior to returning Specify the time of returning the mode activates after the return Mark the devices for...

Страница 62: ...functions of parameter setting and managing the Connexoon Access RTS application table of indicators messages parameters account help signing out from the application The configuration menu enables access to advanced installation functions see chapter 5 SMART GATE ...

Страница 63: ...ces connected with a single button press A green spot preceding a command means that everything went well A red spot means that the command was interrupted purposefully An orange triangle means that a problem appeared In order to obtain more information press the icon SMART GATE ...

Страница 64: ...The messages of Connexoon contain all the information regarding updates and future novelties Messages SMARTGATE ...

Страница 65: ...you can also display widgets for an Apple watch and or mobile phone and specify your ID for the purposes of adjusting history to your own needs Parameters Possibility of home geolocation in order to receive local weather information Turning weather information on the home page on off Turning alarms sent via e mail on off SMART GATE ...

Страница 66: ...My account This sheet includes the information provided during the activation of Connexoon SMART GATE ...

Страница 67: ...t with them in case of having any questions Remain in contact with the fitter entering their contact data in the application Then you can contact them with a single button press A single button press is also enough to obtain the telephone number of the Somfy customer service department Help SMART GATE ...

Страница 68: ...nctions This menu enables registering new compatible devices in the Connexoon application deleting changing device names managing the system security key In order to gain access to these functions press the icon SMART GATE ...

Страница 69: ...Press the pencil icon to the right of the device in order to change its name Press the Configuration tab button Press the menu icon Changing product names in the application SMART GATE ...

Страница 70: ...gle at the top of the screen In order to check whether the product is correct click the Identify button The device will move in one direction and back or it will flash In order to stop the identification press the stop button Press the Save button in order to save the new name SMART GATE ...

Страница 71: ...Registering RTS devices in the CONNEXOON unit Press the menu icon Press the Configuration tab button Press the button SMART GATE ...

Страница 72: ...Hue lights and then confirm this by pressing the button Select the icon representing the product that you want to register in the unit Check the product by moving it using a wall controller or a remote control device Make sure that the controlling element activates only the added product SMART GATE ...

Страница 73: ...ct has been registered correctly by pressing the Test button The device will start moving in one direction and back or it will start flashing for 5 second Press the PROG button of the command activating the product added holding it until the product moves in one direction and back or flashes From that moment on you have 2 seconds to confirm this by pressing the Add button ...

Страница 74: ...Name the product and then click OK The product will appear on the list then SMART GATE ...

Страница 75: ...vice Make sure that the controlling element activates only the removed product Press the PROG button of the command activating the product removed and hold the button for about 3 seconds until the product moves in one direction and back or flashes From that moment on you have 2 seconds to confirm this by pressing the Delete button SMART GATE ...

Страница 76: ...emoved properly by pressing the Test button If the product has been removed properly it will not answer Press the OK button if the product did not move or click Restart if it was closed Press OK in order to finish the procedure SMART GATE ...

Страница 77: ...oon unit directly to the Internet using an Ethernet cable The USB port enables powering the Connexoon unit with a power supply cable The SELECT button enables selecting a channel 6 channels are available The Easy Way 201i drive and the Connexoon controlling device are factory paired they do not require to be installed The LED status light indicates the unit status and the operations carried out 1 ...

Страница 78: ......

Отзывы: