Connection of two actuators
1. The connection between the actuators and the electrical distribution box has to be made prior to connecting that box to the mains.
The M1 actuator has to be installed on the post of the wing that opens first and closes last.
The M1 actuator starts the right wing, which opens first and closes last.
2. Connect the drives in the manner indicated in the table below:
Connect the cable of the drive No. ...
to the terminal No. ...
M1
blue
10
brown
11
M2
blue
12
brown
13
Connection to the power grid
Due to safety reasons these activities have to be performed with the power supply disconnected. Use a 3 x 1.5 mm
2
cable for indoor use (at
least of the H07RN-F type). It is obligatory to use the cable holder provided. Check whether all the low voltage cables endure the impact of
100 N force. Check whether the cables remain unmoved after applying such a force.