38
1. Open the reception tool. Go to
System Settings
.
2. Find the connector you want to remove from the list and click it with the secondary mouse button.
3. Select
Remove connector
to remove the connector from the system. The software asks for your con-
firmation.
4. Repeat steps 2 and 3 for each connector you want to remove.
RESETTING BASE STATION
If the base station has previously been used with any Team² or Cardio GX system (as a main or secondary
base station), it must be reset before it can be set up to the system (as a main or secondary base station)
again.
1. Switch on the base station, do not connect it to the computer or the local area network. Make sure
the other base stations are switched off.
2. Wait until light
is lit on the base station.
3. Push the reset button on the base station front panel with a pen or pencil. The reset button is under
the plug.
4. Add the base station to the system as a main or secondary base station. See more details in
Setting
up base stations
.
SYNCHRONIZING CONNECTORS WITH NEW BASE STATIONS
After replacing the main base station or setting up a secondary base station (after already using the Cardio GX
system), you have to synchronize the connectors with the new base station combination. The Cardio GX
reception tool informs about problems with connectors in
System Settings
. Take the mouse cursor on the
marked connector to read the error message.
If you had connectors taught to the Cardio GX system before the base station combination changed, follow
the steps below:
1. Connect the main base station to the computer or to the router with the cross-over Ethernet cable pro-
vided in the set.
2. Switch on the main base station.
3. Open the reception tool. Go to
System Settings
. Wait until
and
are lit on the main base sta-
tion. It takes approximately 1 minute.
4. Plug the power cable into the charger.
5. Insert connectors into the charger in non-secured mode. For more information, see more details in
Non-secured connector mode
.
6. As soon as connectors are synchronized with the new base station combination, the error noti-
Содержание Cardio GX