Point Grey Flea3 GigE Technical Reference
C GenICam Features
C.7
User Set Control
Name
Display Name
Description
Value
CurrentUserSet
Current User Set
Indicates the user set that is currently in use. At initialization time, the
camera loads the most recently saved user set
0 (default)
1
2
UserSetSelector
User Set Selector
Selects the user set to load or save
Default
User Set 1
User Set 2
UserSetLoad
User Set Load
Loads the user set specified by the User Set Selector to the device and
makes it active
Write Only
UserSetSave
User Set Save
Saves the user set specified by the User Set Selector to the non-volatile
memory of the device
Write Only
DefaultUserSet
Default User Set
Selects the default user set as the default start up set
Default
User Set 1
User Set 2
C.8
Chunk Data Control
Name
Display Name
Description
Value
ChunkModeActive
Chunk Mode
Active
Activates the inclusion of Chunk data in the payload of
the image.
ChunkSelector
Chunk Selector
Selects which chunk data to enable or control
Image
Image CRC
Frame Counter
Offset X
Offset Y
Width
Height
Exposure Time
Gain
Black Level
ChunkEnable
Chunk Enable
Enables the inclusion of the selected Chunk data in the
payload of the image
Revised 10/29/2013
Copyright ©2010-2013 Point Grey Research Inc.
108