12

SEQUENTIAL TRIP SAFETY OPERATION

The model 475 

fl

 ooring stapler operates on a sequen

ti

 al trip system. The sequen

ti

 al 

trip system requires the operator to hold the tool against the work before pulling 
the trigger. This makes accurate fastener placement easier. The sequen

ti

 al  trip 

allows exact fastener loca

ti

 on without the possibility of driving a second fastener on 

recoil. The sequen

ti

 al trip system has a posi

ti

 ve safety advantage because it will not 

accidentally drive a fastener if the tool is contacted against the work – or anything 
else – while the operator is holding the trigger pulled.

TOOL OPERATION CHECK:

CAUTION: Remove all fasteners from tool before performing tool opera

ti

 on check.

SEQUENTIAL TRIP OPERATION:

A. 

Press the contact trip against the work surface, without touching the trigger.

THE TOOL MUST NOT CYCLE.

B. 

Hold the tool o

  the work surface and pull the trigger.

THE TOOL MUST NOT CYCLE.

Release the trigger. The trigger must return to the trigger stop on the frame.

C. 

Pull the trigger and press the contact trip against the work surface.

THE TOOL MUST NOT CYCLE.

D. 

With 

fi

 nger o

  the trigger, press the contact trip against the work surface. Pull 

the trigger.

THE TOOL MUST CYCLE.

DUAL TRIGGER OPERATION 

(P

ATENT

 P

ENDING

)

The dual trigger feature gives you mul

ti

 ple op

ti

 ons for hand orienta

ti

 on and trigger 

actua

ti

 on to allow you to choose the actua

ti

 on method that works best for you for a 

given applica

ti

 on. The following illustra

ti

 ons are two examples. 

Figure 1

Figure 2

9

SPECIFICATIONS

All screws and nuts are metric.

TOOL SPECIFICATIONS:

MODEL

LENGTH

HEIGHT

WIDTH

WEIGHT

475 20 

G

age 

Thin Flooring Stapler

10-1/8” 

(257.1mm)

9-5/8” 

(244.0 mm)

2-5/16” 

(59.7 mm)

3.2 lb 

(1.4 kg)

FASTENER SPECIFICATIONS:

TOOL MODEL

STAPLE 

SERIES

CROWN WIDTH

WIRE SIZE

FASTENER 

LENGTH

475 Twin Trigger 20 
20 

G

age Flooring Stapler

47590

3/16”

(4.8mm)

.035”X0.035”

(1.3 X 0.89mm)

1”

(25mm)

TOOL AIR FITTING:

This tool uses a free-

fl

 ow connector plug, 1/4 NPT. The inside diameter should be 

.200” (5mm) or larger. The 

fi

 

tti

  ng must be capable of discharging tool air pressure 

when disconnected from the air supply.

OPERATING PRESSURE:

70 to 100 PSI

G

. (4.8 to 7.0 kg/cm2). Select the opera

ti

 ng pressure within this range 

for best fastener performance. 

DO NOT EXCEED THE RECOMMENDED OPERATING 

PRESSURE.

AIR CONSUMPTION:

The model 475 requires 3.1 cubic feet per minute (.09 cubic meters) of free air to 
operate at the rate of 100 fasteners per minute, at 80 PSI (5.6 kg/cm

2

). Take the 

actual rate at which the tool will be run to determine the amount of air required. For 
instance, if your fastener usage averages 50 fasteners per minute, you need 50% of 
the tool’s C.F.M. which is required to operate the tool at 100 fasteners per minute.

SEQUENTIAL TRIP OPERATION:

The model 475 

fl

 ooring stapler operates on a sequen

ti

 al trip system. The sequen

ti

 al 

trip system requires the operator to hold the tool against the work before pulling 
the trigger. This makes accurate fastener placement easier. The Sequen

ti

 al  Trip 

allows exact fastener loca

ti

 on without the possibility of driving a second fastener on 

recoil. The Sequen

ti

 al Trip system has a posi

ti

 ve safety advantage because it will not 

accidentally drive a fastener if the tool is contacted against the work – or anything 
else – while the operator is holding the trigger pulled.

LUBRICATION

Apply one or two drops of Air Tool Lubricant, Mobil Velocite #10, or equivalent prior 
to each use. Use more or less frequently depending on usage and duty cycle 

Содержание PORTAMATIC 475 Twin Trigger 20

Страница 1: ...neered and Solid Wood Flooring CAUTION Read important safety instructions AND operation instructions BEFORE operating your Pneumatic Tool Your new Pneumatic Tool is capable of dependable performance throughout its lifetime To take full advantage of these capabilities you should thoroughly understand the proper method and technique of its operation Therefore we suggest you read this manual before o...

Страница 2: ...D CONNECTIONS 10 TOOL OPERATION 11 SEQUENTIAL TRIP SAFETY OPERATION 12 DUAL TRIGGER OPERATION 12 LOADING THE PORTAMATIC 475 FLOORING STAPLER 13 FASTENER POSITIONING ADJUSTMENT 13 MAINTAINING THE PNEUMATIC TOOL 14 TROUBLE SHOOTING 15 PARTS LISTING 16 18 EXPLODED VIEW 19 NOTE Porta Nails tools have been engineered to provide excellent customer satisfaction and are designed to achieve maximum perform...

Страница 3: ...ormal wear neglect abuse accident or repairs attempted or made by other than our national repair center or authorized warranty service centers Driver blades bumpers O rings pistons and piston rings are considered normally wearing parts For optimal performance of your Porta Nails tool always use genuine Porta Nails fasteners and replacement parts THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXP...

Страница 4: ...Equipment Head protection shall conform to American National Standards Institute Z89 1 Protective Headwear for Industrial Workers TOOL MAINTENANCE When working on air tools note the warnings in this manual and use extra care when evaluating problem tools Responsibility for Proper Tool Maintenance The employer and tool operator are responsible for assuring that the tool is kept in safe working orde...

Страница 5: ...ith parts or accessories which perform equivalently to those supplied or recommended by the tool manufacturer Tools Needing Repair The employer shall ensure that tools which require repair are not further used before repair Tags and physical segregation are recommended means of control OSHA s General Industry and Construction regulations require the use of tags Tool Maintenance Instructions The em...

Страница 6: ...p leaks air Damaged gasket or seal Replace gasket or seal Cracked worn head valve Replace head valve Loose cap screws Tighten and recheck Failure to cycle Air supply restriction Check air supply equipment Worn head valve Replace head valve Broken cylinder cap spring Replace cylinder cap spring Head valve stuck in cap Disassemble Check Lubricate Lack of power Broken cylinder cap spring Replace cap ...

Страница 7: ...tool Air pressure too low Staple crown above tongue Increase air pressure Air pressure too high Staple buried Lower air pressure Correct air pressure Staple just below surface FLOOR STAPLE 7 prior to making any modifications to the tool Other Detailed Information Refer to the tool maintenance instructions for detailed information on the proper maintenance of the tool Actuation System This tool uti...

Страница 8: ...knobs located on the positioning shoe The shoe adjustment feature provides close control of the fastener positioning to reduce occurrence of split tongues or dimples in the flooring surface First set the air pressure for consistent drive in the specific work as described on page 4 then use the shoe adjustment knobs to set the desired position of drive The fastener should be positioned so that it e...

Страница 9: ...er 10 1 8 257 1mm 9 5 8 244 0 mm 2 5 16 59 7 mm 3 2 lb 1 4 kg FASTENER SPECIFICATIONS TOOL MODEL STAPLE SERIES CROWN WIDTH WIRE SIZE FASTENER LENGTH 475 Twin Trigger 20 20 Gage Flooring Stapler 47590 3 16 4 8mm 035 X0 035 1 3 X 0 89mm 1 25mm TOOL AIR FITTING This tool uses a free flow connector plug 1 4 NPT The inside diameter should be 200 5mm or larger The fitting must be capable of discharging ...

Страница 10: ...Velocite 10 or equivalent Do not use detergent oil or additives as 11 these lubricants will cause accelerated wear to the seals and Piston Cushion in the tool resulting in poor tool performance and frequent tool maintenance If no airline lubricator is used add oil during use into the air fitting on the tool once or twice a day Only a few drops of oil at a time are necessary Too much oil will only ...

Отзывы: