PNI PORTAMATIC 475 Twin Trigger 20 Скачать руководство пользователя страница 2

2

INTRODUCTION

The Portama

ti

 c 475 

fl

 ooring stapler is a precision-built tool, designed 

for high speed, high volume fastening. This tool will deliver e

  cient, 

dependable service when used correctly and with care. As with any 

fi

 ne power tool, for best performance the manufacturer’s instruc

ti

 ons 

must be followed. Please study this manual before opera

ti

 ng the tool 

and understand the safety warnings and cau

ti

 ons. The instruc

ti

 ons on 

installa

ti

 on, opera

ti

 on and maintenance should be read carefully, and 

the manuals kept for reference. 

Note:

 Addi

ti

  onal safety measures may 

be required because of your par

ti

 cular applica

ti

 on of the tool. Contact 

your Porta-Nails representa

ti

 ve or distributor with any ques

ti

 ons 

concerning the tool and its use. 

INDEX

INTRODUCTION

2

INDEX

2

LIMITED WARRANTY

3

SAFETY INSTRUCTIONS

4

SPECIFICATIONS

9

AIR SUPPLY AND CONNECTIONS

10

TOOL OPERATION

11

SEQUENTIAL TRIP SAFETY OPERATION

12

DUAL TRIGGER OPERATION

12

LOADING THE PORTAMATIC 475 FLOORING STAPLER

13

FASTENER POSITIONING ADJUSTMENT

13

MAINTAINING THE PNEUMATIC TOOL

14

TROUBLE SHOOTING

15

PARTS LISTING

16 - 18

EXPLODED VIEW

19

NOTE:

Porta-Nails tools have been engineered to provide excellent customer sa

ti

 sfac

ti

 on 

and are designed to achieve maximum performance when used with precision 
Porta-Nails fasteners engineered to the same exac

ti

  ng standards. Porta-Nails cannot 

assume responsibility for product performance if our tools are used with fasteners 
or accessories not mee

ti

 ng the speci

fi

 c requirements established for genuine Porta-

Nails nails, staples and accessories.

19

1

1A

2

3

4

5

6

7

9

6

10

11

12

13

14

12

15

16

17

18

19

20

21

24

22

25

26

28

29

8

30

31

32

33

23

34

40

39

38

37

36

35

41

42

43

44

45

46

47

48

49 50

51

52

53

69

68

67

66

54

37

55

56

57

58

59

60

61

62

63

65

64

65

70

71

72

73

74

77

76

75

78

79

80

81

82

83

*6

18U

21

*5

27

27A

*3

*2

*2

47U

1

*2

*2

*3

*6

*2

30U

475 - EXPL

ODED VIEW

Содержание PORTAMATIC 475 Twin Trigger 20

Страница 1: ...neered and Solid Wood Flooring CAUTION Read important safety instructions AND operation instructions BEFORE operating your Pneumatic Tool Your new Pneumatic Tool is capable of dependable performance throughout its lifetime To take full advantage of these capabilities you should thoroughly understand the proper method and technique of its operation Therefore we suggest you read this manual before o...

Страница 2: ...D CONNECTIONS 10 TOOL OPERATION 11 SEQUENTIAL TRIP SAFETY OPERATION 12 DUAL TRIGGER OPERATION 12 LOADING THE PORTAMATIC 475 FLOORING STAPLER 13 FASTENER POSITIONING ADJUSTMENT 13 MAINTAINING THE PNEUMATIC TOOL 14 TROUBLE SHOOTING 15 PARTS LISTING 16 18 EXPLODED VIEW 19 NOTE Porta Nails tools have been engineered to provide excellent customer satisfaction and are designed to achieve maximum perform...

Страница 3: ...ormal wear neglect abuse accident or repairs attempted or made by other than our national repair center or authorized warranty service centers Driver blades bumpers O rings pistons and piston rings are considered normally wearing parts For optimal performance of your Porta Nails tool always use genuine Porta Nails fasteners and replacement parts THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXP...

Страница 4: ...Equipment Head protection shall conform to American National Standards Institute Z89 1 Protective Headwear for Industrial Workers TOOL MAINTENANCE When working on air tools note the warnings in this manual and use extra care when evaluating problem tools Responsibility for Proper Tool Maintenance The employer and tool operator are responsible for assuring that the tool is kept in safe working orde...

Страница 5: ...ith parts or accessories which perform equivalently to those supplied or recommended by the tool manufacturer Tools Needing Repair The employer shall ensure that tools which require repair are not further used before repair Tags and physical segregation are recommended means of control OSHA s General Industry and Construction regulations require the use of tags Tool Maintenance Instructions The em...

Страница 6: ...p leaks air Damaged gasket or seal Replace gasket or seal Cracked worn head valve Replace head valve Loose cap screws Tighten and recheck Failure to cycle Air supply restriction Check air supply equipment Worn head valve Replace head valve Broken cylinder cap spring Replace cylinder cap spring Head valve stuck in cap Disassemble Check Lubricate Lack of power Broken cylinder cap spring Replace cap ...

Страница 7: ...tool Air pressure too low Staple crown above tongue Increase air pressure Air pressure too high Staple buried Lower air pressure Correct air pressure Staple just below surface FLOOR STAPLE 7 prior to making any modifications to the tool Other Detailed Information Refer to the tool maintenance instructions for detailed information on the proper maintenance of the tool Actuation System This tool uti...

Страница 8: ...knobs located on the positioning shoe The shoe adjustment feature provides close control of the fastener positioning to reduce occurrence of split tongues or dimples in the flooring surface First set the air pressure for consistent drive in the specific work as described on page 4 then use the shoe adjustment knobs to set the desired position of drive The fastener should be positioned so that it e...

Страница 9: ...er 10 1 8 257 1mm 9 5 8 244 0 mm 2 5 16 59 7 mm 3 2 lb 1 4 kg FASTENER SPECIFICATIONS TOOL MODEL STAPLE SERIES CROWN WIDTH WIRE SIZE FASTENER LENGTH 475 Twin Trigger 20 20 Gage Flooring Stapler 47590 3 16 4 8mm 035 X0 035 1 3 X 0 89mm 1 25mm TOOL AIR FITTING This tool uses a free flow connector plug 1 4 NPT The inside diameter should be 200 5mm or larger The fitting must be capable of discharging ...

Страница 10: ...Velocite 10 or equivalent Do not use detergent oil or additives as 11 these lubricants will cause accelerated wear to the seals and Piston Cushion in the tool resulting in poor tool performance and frequent tool maintenance If no airline lubricator is used add oil during use into the air fitting on the tool once or twice a day Only a few drops of oil at a time are necessary Too much oil will only ...

Отзывы: