![PNI DU160 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/pni/du160/du160_user-manual_1569880019.webp)
-
17
-
and digital tube
do not light.
points of "power input"
on the circuit board
terminals.
no 24V
Replace the circuit board.
No working,
digital tube
display"H08"
Set P6 parameters by
referring to 3.1.3,
increase high-speed
current (high-speed
torque), and restart the
work.
Problem
solve
End
Fault
remain
1.Replace the motor.
2.Replace the circuit
board.
3.Disconnect the
connection from the
door to the rocker arm
and check whether the
door is blocked.
Open not in
place
Increase the value of P13 ,increase the angle of open door .
Open without
buffer
Increase the value of P12,increase the buffer angle
of open door.
Close not in
place
Increase the value of P19 , increase the value of low-speed current
(low-speed torque), or increase the valueof P2
,
increase the
buffer speed.
Close without
buffer
Increase the value of P05,increase the buffer angle
of close door.
When the door
is closed, the
lock cannot
lock the door.
Use a universal meter to
Check whether there isa
12V voltage at the two
points of
"electromagnetic lock"
on the circuit board
terminals.
12V
1. Check and adjust the
electromagnetic lock ,
make it flat with the iron
plate.
2. Replace the
electromagnetic lock.
3. Check and replace
the connection.
no 12V
Replace the circuit board.