Warning: A. When the electrical part is connected, live work is strictly
prohibited.Power can be energized after all connections .
B. Do not connect the positive and negative poles of the power supply
inverse, otherwise the equipment will be damaged.
Note:
A. Please choose an electromagnetic lock with supply voltageis 12V DC and
the power
≤
9W or our company's electromagnetic lock.Otherwise it will cause
abnormal operation or circuit damage.
B: When leaving factory, the motor wire has been connected, do not take it
out without any special case.
C: Opening signal of external access control equipment :
a: When the access control equipment is the output of switch quantity (dry
contact), the close switch controls the opening of the door, and the switch should be
open usually, without polarity requirements.
b: When voltage output (wet contact), add transfer module.