When the door moves towards opening ,please refer to(3.1) and dial the open
direction dial switch(red) on the circuit board to the opposite direction, and then
observe whether it enters the normal state A.
Note: please do not block when learning closing position, otherwise the blocking
position will be regarded as the closing position!
4.2 Opening Debugging
A.
Opening Angle: if the opening Angle is not enough, increase the value of P13;
if it is too large, decrease the value of P13 to reach the desiredAngle.
B.
Opening speed: adjust the value of P10, the larger the value, the faster the
speed, the smaller the slower speed.
C.
Time of open and hold : When the door open in place, the time of stopping
at the position, and adjust the value of P04 (in seconds).
4.3.
Closing Debugging
A. Closing speed: Adjust the value of P01, the larger the value, the faster thespeed,
the smaller the slower;
B: Close-slow Angle: Adjust the value of P05, the larger the value, the larger the
Angle, the smaller value the smaller angle.
4.4.
Other Debugging
A: Adjust back pushing current:
Set P06, factory value is 110, that is, set motor working current to 1.10A.If the
motor works abnormally and the LED digital tube shows "H08" alarm, the P06 value
must be increased.
B. If the door is not closed in place, increase the value of P19 orP02.
C. If the close buffer speed is too fast, the P02 value can be reduced.
D. Please refer to 3.1 for setting other parameters, it should be according tothe
situation on site.
Chapter V: Common troubles and Removal
Fault
phenomena
Fault Judgment
Treatment Measures
No working,
and the 3.3v
power indicator
Use a universal meter to
Check whether there is a
24V voltage at the two
24V
1.
Check & replace24V
power supply.
2.
Check & replace wiring.