12
-
3.2. After installation and wiring , turn on the power and the door opener will enter
the learning state of the closing position (digital tube display
“
H07
”)
.
After close and finish learning , it enters the standby state, and the digital tube
displays"_ _ _"in the standby state.
3.3.Function and corresponding digital tube display
Dis-
play
Explain
Default
values
Range
Remarks
P01
Closing
speed
6
1-10
The
numerical
larger,
the
faster.
value
speed
P02
Closing slow
speed
3
1-10
The
numerical
larger,
the
faster.
value
speed
P03
Closing delay
5
1-15
Force the door close in
place.
P04
Opening &
holding time
5
1-99
Residence time
after
opening the
door
in
place.
P05
Closing slow
angle
30
5-60
The
numerical
larger,
the
larger.
value
angle
P06
Current
Detection (High
Speed)
110
20-240
Unit is 0.01A
P07
Wind resistance
time
3
1-10
Unit is S