![Pneumat Systems Cardox CO2 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/pneumat-systems/cardox-co2/cardox-co2_technical-manual_1569667009.webp)
Cardox Techical Manual
Page
9
12. Weigh Filled Tube
Place the filled tube
back on the scale to
check the weight of CO
2
that was pumped into the
tube.
13. Adjust Air Pressure &
Refill
If the tube does not
have a sufficient CO
2
charge (see chart be-
low) put it back into the
fill station and repeat
Steps 4 through 11.
The air pressure to the
pump may need to be
increased to obtain a
proper fill weight.
14. Check Each End of
Tube for Leaks
Dip both ends of tube in
a bucket of water at an
angle to check for leaks.
Hold under water for a
few seconds and watch
for bubbles rising up
from the tube end.
15. Put Back in Vise & Re-
seal (IF LEAKS)
If tube is leaking clamp
it into the vise and review
troubleshooting section
of this manual. Repeat fill
procedure.
16. Tape Over Contacts
If there are no leaks cover
the electrical contacts on
the Cardox fill head with
a few wraps of electri-
cal tape. The tape signi-
fies that the tube is now
charged and ready to be
used.
CO
2
Charge Weights (min):
Series 3700 Tube Series 5700 Tube
1.3 lbs
1.8 lbs
0.60 kg
0.82 kg
Содержание Cardox CO2
Страница 1: ...A B C D 8 7 6 TECHNICAL MANUAL 110 Mohr Drive Mankato MN 56001 1 800 458 9446 www pneumat com ...
Страница 22: ...Cardox Techical Manual Page 22 5780 0005 Cardox Fill Stand Assembly Parts List ...
Страница 25: ...Cardox Techical Manual Page 25 5730 0003 Auto Fill Activating Head w Eyebolt Parts List ...
Страница 27: ...Cardox Techical Manual Page 27 Series 3700 Firing Head Tube Body Discharge Head Parts List ...
Страница 28: ...Cardox Techical Manual Page 28 Series 5700 Firing Head Tube Body Discharge Head Parts List ...