0

6.  

    

 

 

RECEIVER/TRAMSMITTER PROGRAMMING

CAUTION:

Mount the receiver in a location removed from 
metal. Metal objects (duct work, wire mesh screens, 

boxes) will reduce RF range.

CAUTION:

Graded applications must secure the housing cover 
with the included screw.

1.   Use the provided anchors and screws to mount the 
 

receiver in a location accessible for future maintenance.

2.   Perform a walk test, activating each transmitter assigned    
 

to the receiver and ensuring a good signal.

Dimensions: 

165 mm x 89 mm x 25 mm (6.5” x 3.5” x 1”).

Weight:

 280 g (.62 lb)

Operating environment:

 0°- 60°C (32°- 140°F), 90% 

relative humidity, noncondensing.

Power requirement: 

11 - 14 VDC; 400 mA

Current consumption: 

Approx. 400 mA

Output specifications: 

Form C relay 1A @ 28 VDC, 0.5 @ 

30 VAC resistive load

Input specifications: 

A low is less than .5 V; a high is greater 

than 2.5 V. Reset input: Contact closure, momentary low.

Receiver type: 

Frequency hopping spread spectrum.

Operating frequency: 

868-869 MHz

Tamper: 

Type B, fixed device.

Number of points/Transmitters: 

16.

Number of outputs: 

Six Form C relay outputs

Event history log capacity:

 50 events (first-in, first-out 

replacement).

© Inovonics, 2009 - www.inovonics.com 

4

1.

Use the provided anchors and screws to mount the receiver in a location 

accessible for future maintenance.

2.

Perform a walk test, activating each transmitter assigned to the receiver and 

ensuring a good signal.

7 Specifications

Dimensions: 

165 mm x 89 mm x 25 mm (6.5" x 3.5" x 1").

Weight: 

280 g (.62 lb)

Operating environment: 

0°- 60°C (32°- 140°F), 90% relative humidity, non-

condensing.

Power requirement: 

11 - 14 VDC; 400 mA

Current consumption: 

Approx. 400 mA

Output specifications: 

Form C relay 1A @ 28 VDC, 0.5 @ 30 VAC resistive load

Input specifications: 

A low is less than .5 V; a high is greater than 2.5 V. Reset input: 

Contact closure, momentary low.

Receiver type: 

Frequency hopping spread spectrum.

Operating frequency: 

868-869 MHz

Tamper:  

Type B, fixed device.

Number of points/Transmitters: 

16.

Number of outputs: 

Six Form C relay outputs

Event history log capacity: 

50 events (first-in, first-out replacement).

 Figure 4  

Tamper, Reset, Arm and Clear to Set Circuits

7.1 Means of Conformity

Inovonics Wireless Corporation declares that the product listed above is in conformity 

with the essential requirements and provisions of the following Council Directives:

• R&TTE Directive

• Low Voltage Directive

• EMC Directive

and conforms to the following standards:

• EN 300 220 Receiver Class 1, Environmental Category 1

• EN 60950

• EN 301 489

• EN 50130 Environmental Class II

• EN 50131 Security Grade 2

• EN 20131-2-2:2008

• TS 50131-2-2:2004

• PD6662:2004 Incorporating Amendments Numbers 1 and 2

Product tested by Telefication B.V.

8 Warranty/Disclaimer

Caution: 

Changes or modifications to this unit not expressly approved by Inovonics 

Wireless Corporation may void the installer's authority to operate the equipment as 

well as the product warranty. 
Inovonics Wireless Corporation ("Inovonics") warrants its products ("Product" or 

"Products") to conform to its own specifications and to be free of defects in materials 

and workmanship under normal use for a period of thirty-six (36) months from the date 

of manufacture. Within the warranty period, Inovonics will repair or replace, at its 

option, all or any part of the warranted Product. Inovonics will not be responsible for 

dismantling and/or reinstallation charges. To exercise the warranty, the User ("User", 

"Installer" or "Consumer") must work directly through their authorized distributor who 

will be given a Return Material Authorization ("RMA") number by Inovonics. Details of 

shipment will be arranged directly through the authorized distributor.

This warranty is void in cases of improper installation, misuse, failure to follow 

installation and operating instructions, alteration, accident or tampering, and repair by 

anyone other than Inovonics.

This warranty is exclusive and expressly in lieu of all other warranties, obligations or 

liabilities, whether written, oral, express, or implied. There is no warranty by Inovonics 

that Inovonics product will be merchantable or fit for any particular purpose, nor is 

there any other warranty, expressed or implied, except as such is expressly set forth 

herein.  In no event shall Inovonics be liable for an incidental, consequential, indirect, 

special, or exemplary damages, including but not limited to loss of profit, revenue, or 

contract, loss of use, cost of down time, or interruption of business, nor any claim 

made by distributor's customers or any other person or entity. 

This warranty will not be modified or extended. Inovonics does not authorize any 

person to act on its behalf to modify or extend this warranty. 

This warranty will apply only to Inovonics Products. Inovonics will not be liable for any 

direct, incidental, or consequential damage or loss whatsoever, caused by the 

malfunction of Product due to products, accessories, or attachments of other 

manufacturers, including batteries, used in conjunction with Inovonics Products. 

Note: 

E-mail [email protected] for a copy of the CE Declaration of Conformity.

GN

GN

GN
GN

Tamp

Res

Clear to 

Ja

Figure 4

 Tamper, Reset, Arm and Clear to Set Circuits

7.1 Means of Conformity

Inovonics Wireless Corporation declares that the product 
listed above is in conformity with the essential requirements 
and provisions of the following Council Directives: 

•   R&TTE Directive
•   Low Voltage Directive
•   EMC Directive and conforms to the following standards:
•   EN 300 220 Receiver Class 1, Environmental Category 1
•   EN 60950
• 

EN 301 489

•   EN 50130 Environmental Class II
•   EN 50131 Security Grade 2
• 

EN 20131-2-2:2008

•   TS 50131-2-2:2004
•   PD6662:2004 Incorporating Amendments

CAUTION:

Changes or modifications to this unit not expressly 

approved by Inovonics Wireless Corporation may 
void the installer’s authority to operate the equip-
ment as well as the product warranty.

Inovonics Wireless Corporation (”Inovonics”) warrants its 
products (”Product” or”Products”) to conform to its own 
specifications and to be free of defects in materials

and workmanship under normal use for a period of thirty-six 

(36) months from the date of manufacture. Within the war-
ranty period, Inovonics will repair or replace, at its option, all 
or any part of the warranted Product. Inovonics will not be 
responsible for dismantling and/or reinstallation charges. To 

exercise the warranty, the User (”User”,”Installer” or ”Consu

-

mer”) must work directly through their authorized distributor 
who will be given a Return Material Authorization (”RMA”) 
number by Inovonics. Details of shipment will be arranged di-
rectly through the authorized distributor. This warranty is void 
in cases of improper installation, misuse, failure to follow
installation and operating instructions, alteration, accident or 
tampering, and repair by anyone other than Inovonics.

This warranty is exclusive and expressly in lieu of all other 

warranties, obligations or liabilities, whether written, oral, 

express, or implied. There is no warranty by Inovonics that 

Inovonics product will be merchantable or fit for any particular 

purpose, nor is there any other warranty, expressed or implied, 
except as such is expressly set forth herein. In no event shall 

Inovonics be liable for an incidental, consequential, indirect,

special, or exemplary damages, including but not limited to loss 

of profit, revenue, or contract, loss of use, cost of down time, 
or interruption of business, nor any claim made by distributor’s 
customers or any other person or entity. This warranty will 

not be modified or extended. Inovonics does not authorize any
person to act on its behalf to modify or extend this warranty.

This warranty will apply only to Inovonics Products. Inovonics 
will not be liable for any direct, incidental, or consequential da-
mage or loss whatsoever, caused by the malfunction of Product 
due to products, accessories, or attachments of other
manufacturers, including batteries, used in conjunction with 
Inovonics Products.

NOTE:

E-mail [email protected] for a copy of the CE 

Declaration of Conformity.

6.6 Mount the Receiver

6.8 Warranty/Disclaimer

6.7 Specifications

Содержание OS-4 WRK

Страница 1: ... Fax 1 609 655 0919 info plymovent com 1 Safety 2 2 Important safety instruction 3 3 Introduction 3 4 System components 4 5 Installation 4 5 6 Reciever programming 6 6 1 Overview 6 6 2 Installation and Start up 7 6 3 System Test Mode 10 6 4 Operation 11 6 5 Connect input Output Cabling 11 6 6 Mount the Receiver 12 6 7 Specifications 12 6 8 Receiver Warrantee 12 7 Wire Diagram 13 8 Operation 14 9 W...

Страница 2: ... not be altered Modifications Modifications of parts of the product is not allowed except the bottom plate which is allowed to be used as entrance point for external cabling WARNING ELECTROCUTION HAZARD Disconnect mains before servicing Failure to do so could result in serious personal injury or death WARNING PRODUCT MAY CONTAIN SHARP EDGES Use care when servicing unit Failure to do so could resul...

Страница 3: ...ead the Prodcut User Manual and Important Safety Instructions carefully Failure to follow these instructions could cause a malfunction in the system or unsatisfactory service B Follow a regular service and maintenance schedule for efficient operation To reduce the risk of electric shock fire and injury to persons Do not use the OS 4 WRK in wet or damp locations Do not use the OS 4 WRK outdoors 2 1...

Страница 4: ...d not be blocking any safety equipment or cause any safety hazards The mounting surface should be a solid surface 2 Add a hole if required to the OS 4 enclosure 3 Run the wire from the OS 4 WRK R into the OS 4 panel Cut the wires to the proper length strip ends insert into proper leads tighten wire holders tuck away or wire tie and lose wire 4 Connect the power wires to the load side of the 24 vol...

Страница 5: ...e pressure switch Tap the hole with a pipe tread and thread the pressure switch into the hole 5 Connect the pressure switch to the transition 6 Reconnect the hose to the trolley 7 Install the mounting clip for the Transmitter on the top of the exhaust hose crab Note screws used must be flush mount to allow for proper fitting of transmitter Note make sure to place the provided zip tie under the cli...

Страница 6: ...ics com EE4216MR EchoStream Receiver Installation and Operation Manual 05395G 1 Overview Inovonics EchoStream technology is designed to minimize dead spots in transmission areas using diversity reception and advanced signal processing The EE4216MR receiver allows you to add up to 16 transmitters and six outputs to any application The EE4216MR is compliant with EN50131 1 Security Grade 2 Environmen...

Страница 7: ... To connect power to the receiver NOTE The default level 2 authorized user password is 3446 Level 3 authorized installer access A level 3 authorized installer has the ability to access all INSTALL SERVICE menus A level 3 authorized installer can also view receiver system status indicators as well as change receiver system parameters and perform all receiver functions NOTE The default level 3 autho...

Страница 8: ...nter button to select Inactive Out Maps transmitter repeater inactivity fault output a Use the Up Down buttons to scroll through the output numbers Choosing will disable inactivity reporting b Press Enter to select the output to use for this transmitter repeater s inactivity transmission Inactive Output Type Selects the output type for the inac tive condition a Use the Up Down buttons to scroll th...

Страница 9: ...the Enter button to select Momentary The output turns on for the programmed duration then turns off regardless of the device status Press the Enter button to select MOMENT displays when selected This sets the time that the output will stay activated The valid range 0 5 to 99 5 seconds in 0 5 second increments Use the Up and Down buttons to select press the Enter button to select Text Enter eight c...

Страница 10: ...the Back button and remove the wire between the reset terminal and ground 4 RESET CONFIG displays press the Enter button 2 12 Select Language 1 At the SELECT LANGUAGE prompt press Enter 2 Use the Up Down buttons to scroll through the language 6 RECEIVER TRAMSMITTER PROGRAMMING options The CLEAR LANG option resets the language to the default and exits the INSTALL SERVICE menu 3 Press Enter to selec...

Страница 11: ... Caution Graded applications must have a password of at least four digits Passwords can be up to eight digits long The default authorized user password is 3446 the default authorized installer password is 1234 To change the password 1 From the INSTALL SERVICE menu press Enter at the CHANGE PASSWORD prompt 2 Use the Up Down buttons to select either USER PASSWORD or INSTALL PASSWORD press Enter to s...

Страница 12: ...ls of shipment will be arranged directly through the authorized distributor This warranty is void in cases of improper installation misuse failure to follow installation and operating instructions alteration accident or tampering and repair by anyone other than Inovonics This warranty is exclusive and expressly in lieu of all other warranties obligations or liabilities whether written oral express...

Страница 13: ...PUM_WRK_100217_EN 13 140 7 WIRE DIAGRAM ...

Страница 14: ... One month after initial installation check all connections and mounting hardware for proper tightness Then check all con nections yearly Battery replacement is expected in One to TwoYears for each transmitter depending on usage The product has been designed to function without problems for a long time with a minimum of maintenance In order to guarantee this some simple regular maintenance and cle...

Отзывы: