1. Safety .................................................................................. 2
2. Important safety instruction ........................................ 3
3. Introduction ..................................................................... 3
4. System components  ...................................................... 4
5. Installation......................................................................4-5
6. Reciever programming ................................................... 6
6. 1 Overview........................................................................6
6.2 Installation and Start-up...............................................7
6.3 System Test Mode.......................................................10
6.4 Operation.....................................................................11
6.5 Connect input / Output Cabling..............................11
6.6 Mount the Receiver.................................................... 12
6.7 Specifications................................................................12
6.8 Receiver Warrantee....................................................12
7. Wire Diagram ................................................................13
8. Operation .......................................................................14
9.  Warrenty ........................................................................14
10. Maintenance .................................................................14
11. Disposal ........................................................................14
12. CE Declaration.............................................................14

PRODUCT USER MANUAL

Thank you for buying a Plymovent product. Before you unpack and put it into operation please read this 

product manual carefully,  and follow the instructions.

This manual should be handed over and kept by the service department  

after the installation.

MAN_WRK_EN
5757-1011-100413:Rev1.1

Содержание OS-4 WRK

Страница 1: ... Fax 1 609 655 0919 info plymovent com 1 Safety 2 2 Important safety instruction 3 3 Introduction 3 4 System components 4 5 Installation 4 5 6 Reciever programming 6 6 1 Overview 6 6 2 Installation and Start up 7 6 3 System Test Mode 10 6 4 Operation 11 6 5 Connect input Output Cabling 11 6 6 Mount the Receiver 12 6 7 Specifications 12 6 8 Receiver Warrantee 12 7 Wire Diagram 13 8 Operation 14 9 W...

Страница 2: ... not be altered Modifications Modifications of parts of the product is not allowed except the bottom plate which is allowed to be used as entrance point for external cabling WARNING ELECTROCUTION HAZARD Disconnect mains before servicing Failure to do so could result in serious personal injury or death WARNING PRODUCT MAY CONTAIN SHARP EDGES Use care when servicing unit Failure to do so could resul...

Страница 3: ...ead the Prodcut User Manual and Important Safety Instructions carefully Failure to follow these instructions could cause a malfunction in the system or unsatisfactory service B Follow a regular service and maintenance schedule for efficient operation To reduce the risk of electric shock fire and injury to persons Do not use the OS 4 WRK in wet or damp locations Do not use the OS 4 WRK outdoors 2 1...

Страница 4: ...d not be blocking any safety equipment or cause any safety hazards The mounting surface should be a solid surface 2 Add a hole if required to the OS 4 enclosure 3 Run the wire from the OS 4 WRK R into the OS 4 panel Cut the wires to the proper length strip ends insert into proper leads tighten wire holders tuck away or wire tie and lose wire 4 Connect the power wires to the load side of the 24 vol...

Страница 5: ...e pressure switch Tap the hole with a pipe tread and thread the pressure switch into the hole 5 Connect the pressure switch to the transition 6 Reconnect the hose to the trolley 7 Install the mounting clip for the Transmitter on the top of the exhaust hose crab Note screws used must be flush mount to allow for proper fitting of transmitter Note make sure to place the provided zip tie under the cli...

Страница 6: ...ics com EE4216MR EchoStream Receiver Installation and Operation Manual 05395G 1 Overview Inovonics EchoStream technology is designed to minimize dead spots in transmission areas using diversity reception and advanced signal processing The EE4216MR receiver allows you to add up to 16 transmitters and six outputs to any application The EE4216MR is compliant with EN50131 1 Security Grade 2 Environmen...

Страница 7: ... To connect power to the receiver NOTE The default level 2 authorized user password is 3446 Level 3 authorized installer access A level 3 authorized installer has the ability to access all INSTALL SERVICE menus A level 3 authorized installer can also view receiver system status indicators as well as change receiver system parameters and perform all receiver functions NOTE The default level 3 autho...

Страница 8: ...nter button to select Inactive Out Maps transmitter repeater inactivity fault output a Use the Up Down buttons to scroll through the output numbers Choosing will disable inactivity reporting b Press Enter to select the output to use for this transmitter repeater s inactivity transmission Inactive Output Type Selects the output type for the inac tive condition a Use the Up Down buttons to scroll th...

Страница 9: ...the Enter button to select Momentary The output turns on for the programmed duration then turns off regardless of the device status Press the Enter button to select MOMENT displays when selected This sets the time that the output will stay activated The valid range 0 5 to 99 5 seconds in 0 5 second increments Use the Up and Down buttons to select press the Enter button to select Text Enter eight c...

Страница 10: ...the Back button and remove the wire between the reset terminal and ground 4 RESET CONFIG displays press the Enter button 2 12 Select Language 1 At the SELECT LANGUAGE prompt press Enter 2 Use the Up Down buttons to scroll through the language 6 RECEIVER TRAMSMITTER PROGRAMMING options The CLEAR LANG option resets the language to the default and exits the INSTALL SERVICE menu 3 Press Enter to selec...

Страница 11: ... Caution Graded applications must have a password of at least four digits Passwords can be up to eight digits long The default authorized user password is 3446 the default authorized installer password is 1234 To change the password 1 From the INSTALL SERVICE menu press Enter at the CHANGE PASSWORD prompt 2 Use the Up Down buttons to select either USER PASSWORD or INSTALL PASSWORD press Enter to s...

Страница 12: ...ls of shipment will be arranged directly through the authorized distributor This warranty is void in cases of improper installation misuse failure to follow installation and operating instructions alteration accident or tampering and repair by anyone other than Inovonics This warranty is exclusive and expressly in lieu of all other warranties obligations or liabilities whether written oral express...

Страница 13: ...PUM_WRK_100217_EN 13 140 7 WIRE DIAGRAM ...

Страница 14: ... One month after initial installation check all connections and mounting hardware for proper tightness Then check all con nections yearly Battery replacement is expected in One to TwoYears for each transmitter depending on usage The product has been designed to function without problems for a long time with a minimum of maintenance In order to guarantee this some simple regular maintenance and cle...