0000101887/010920/B KUA-160
8
Fig. 4.10
A
A
Connection of the litz wire to the duct
• Measure the earth connection between the hood and the
duct. The electrical resistance must be lower than 10 ohm.
ATTENTION!
If the electrical resistance is over 10 ohm, the litz
wire connection is not correct. In that case: make
sure that all litz wires from the hood to the duct are
interconnected.
Fig. 4.11
< 10 ohm
< 10 ohm
Earth connection
5
USE
Personal protective equipment (PPE)
During use, use PPE to avoid injury. This
also applies for persons who enter the work
area.
5.1
Controls
The hood of the arm is provided with a handle for easy
positioning and a valve to regulate or shut off the airflow. All
movement of the arm is controlled from the hood.
A
Sealed shut-off valve (H-D types only)
B Control valve
C Handle
180°
180°
A
B
A
C
B
180°
180°
A
B
A
C
B
180°
180°
A
B
A
C
B
Fig. 5.1 Controls
5.2
Use
• Use the handle (ref. Fig. 5.1C) to position the hood of the
arm at max. 480 mm (19 in.) from the source of pollution.
• Make sure that the valve (ref. Fig. 5.1A/B) is open.
• Turn on the connected extraction fan or system.
• Start welding.
•
If desired, partly close the valve to adjust the airflow.
• When the welding position changes, move the hood to the
correct position in relation to the weld.
•
Turn off the connected extraction fan or system approx. 20
seconds after finishing welding.
A
A
A = 480 mm (19 in.)
Fig. 5.2 Correct position of the hood