For mounting of the wall bracket to the stanchion:
• proceed with paragraph
• subsequently: proceed with the instructions of Fig. 4.7
(paragraph
4.5.2 KUA-160/S on a wall bracket
For mounting of the arm to a wall bracket:
• proceed with the instructions of Fig. 4.5 (paragraph
• subsequently: proceed with the instructions of Fig. 4.7
(paragraph
4.5.3 KUA-160/S on a mobile unit
TIP
Do a balance check of the arm before you fasten the
hoses. Refer to section 6.2.
•
Install the rotating flange (C) on the filter unit with the 8
bolts M6x25 (A) + washers M6 (B).
A (8x)
B (8x)
C
B
A
C
D
F
E
A (8x)
B (8x)
C
B
A
C
D
F
E
Fig. 4.6
Rotating flange
• Move the hose clamp (C) and the arm swivel ring (incl.
rubber collar) (D) over the hinge rod (B).
•
Put the washer M20 (E) on the rotating flange (F).
•
Put the hinge rod (B) in the rotating flange (F).
• Put the hose (A) over the arm swivel ring (D).
• Use the rubber collar to make the connection airtight.
• Attach the hose (A) to the swivel ring (D) with the hose
clamp (C).
ATTENTION!
Make sure to install the washer M20 (E) between
the rotating flange and the swivel ring to avoid
damage.
A (8x)
B (8x)
C
B
A
C
D
F
E
A (8x)
B (8x)
C
B
A
C
D
F
E
Fig. 4.7 Arm on mobile unit
For mounting of the hood:
• proceed with paragraph
4.6
Hood
• Loosen the mounting material that is attached to the hood
hinge.
• Install the extraction hood (G) with the bolt (F), 2 washers
(E), 2 spring washers (D) and a locknut (C).
• Install the hood collar (H) to the hood (G). Fasten it with
the clip.
• Install the hose (A) to the hood.
• Fasten the hose with a hose clamp (B).
Fig. 4.8
C
A
F
H
G
D (2x)
D (2x)
E (2x)
Hood mounting
4.7
KUA-160 ATEX
The KUA-160 ATEX arm is factory-wise provided with litz wires
between the metal parts, including the spring steel wires of
the hoses. To make the arm suitable for use in potentially
explosive atmospheres, you must make an earth connection.
• Connect the litz wire (A) to the extraction hood with the
faston connector.
Fig. 4.9
A
A
Connection of the litz wire to the hood
• Connect the other litz wire (A) to the extraction duct with a
self-tapping screw
9
.
• Make sure that the rotation of the arm is not obstructed by
the litz wire.
9. Size 4,2 mm