Plymovent KUA-160/2H Скачать руководство пользователя страница 4

0000101887/010920/B KUA-160 

3

Refer to the available product data sheet for 

detailed product specifications.

1.8 

Ambient and process conditions

Process temperature:

 

- min.

 

- nom.

 

- max.

 

-

5°C (41°F)

 

-

20°C (68°F)

 

-

70°C (158°F)

Max. relative humidity

90%

Outdoor use allowed

no

PRODUCT DESCRIPTION

2.1 

Components

The product consists of the following main components and 

elements:

Fig. 2.1

A  Wall bracket

3

Rotating flange

C  Hose

D  Inner tube

E  Middle hinge

F  Outer tube

Sealed shut-off valve

4

H  Hood incl. control valve

Fig. 2.1 

C

A

B

D

E

H

G

F

Main components and elements

2.1.1  KUA-160 ATEX

KUA-160 ATEX arms are suitable for use in potentially 

explosive environments. They comply with ATEX directives due 

to:

 

- antistatic hoses instead of standard hoses

 

- litz wires that interconnect the metal parts of the arm

3.  Only applicable for 

H

 types

4.  Only applicable for 

H-D

 types 

2.2 

Operation

The welding fume is extracted through the hood of the arm by 

a single or central fan. The extraction arm discharges the 

polluted air to an extraction duct with filter unit or directly to 

the atmosphere. 

The hood of the arm is fitted with a control valve to shut off or 

regulate the airflow. The valve is mostly used when several 

extraction arms are integrated in a line installation; in such 

configurations closing the valve prevents the loss of costly 

heated air.

SAFETY

General

The manufacturer does not accept any liability for 

damage to the product or personal injury caused by 

ignoring of the safety instructions in this manual, or 

by negligence during installation, use, maintenance, and repair 

of the product mentioned on the cover of this document and 

any corresponding accessories. Specific working conditions or 

used accessories may require additional safety instructions. 

Immediately contact your supplier if you detect a potential 

danger when using the product.

The user of the product is always fully responsible 

for observing the local safety instructions and 

regulations. Observe all applicable safety 

instructions and regulations.

User manual

 

- Everyone working on or with the product, must be familiar 

with the contents of this manual and must strictly observe 

the instructions therein. The management should instruct the 

personnel in accordance with the manual and observe all 

instructions and directions given. 

 

- Do not change the order of the steps to perform.

 

- Keep the manual with the product. 

Users

 

- The use of this product is exclusively reserved to authorised, 

trained and qualified users. Temporary personnel and 

personnel in training can only use the product under 

supervision and responsibility of skilled engineers. 

 

- Stay alert and keep your attention to your work. Do not use 

the product when you are under the influence of drugs, 

alcohol or medicine. 

 

- The product is not to be used by children or persons with 

reduced physical, sensory or mental capabilities, or lack of 

experience and knowledge, unless they have been given 

supervision or instruction. 

 

- Children must be supervised not to play with the product.

Intended use

5

The product has been designed exclusively for extracting 

fumes and particles which are released during the most 

common welding and cutting processes. Using the product for 

other purposes is considered contrary to its intended use. The 

manufacturer accepts no liability for any damage or injury 

resulting from such use. The product has been built in 

accordance with state-of-the-art standards and recognised 

safety regulations. Only use this product when in technically 

5.  “Intended use” as explained in EN-ISO 12100-1 is the use for which the 

technical product is suited as specified by the manufacturer, inclusive of his 

directions in the sales brochure. In case of doubt it is the use which can be 

deduced from the construction, the model and the function of the technical 

product which is considered normal use. Operating the machine within the 

limits of its intended use also involves observing the instructions in the user 

manual.

Содержание KUA-160/2H

Страница 1: ...www plymovent com Extraction arm A KUA 160 H S ATEX Installation and user manual EN...

Страница 2: ...lation use maintenance and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of the type given on the cover page T...

Страница 3: ...h The arm is fitted with a control valve and is 360 rotatable1 The hood is 90 movable in four directions The KUA 160 arm is available in four different types type H for hanging mounting wall bracket i...

Страница 4: ...always fully responsible for observing the local safety instructions and regulations Observe all applicable safety instructions and regulations User manual Everyone working on or with the product must...

Страница 5: ...cement saw dust wood dust etc Inspect the product and check it for damage Verify the functioning of the safety features During use always use Personal Protective Equipment PPE to avoid injury This als...

Страница 6: ...re depends on the wall type You can mount the wall bracket on e g A a thin brick or concrete wall min thickness 100 mm with four threaded rods M10 B a thick brick or concrete wall with four cotter bol...

Страница 7: ...bolts M6x25 washers M6 Fig 4 3 A B C D E F B D F G G Mounting of the arm For mounting of the hood refer to paragraph 4 6 In case of a KUA 160 H ATEX subsequently proceed with paragraph 4 7 4 4 4 Fan...

Страница 8: ...ivel ring D with the hose clamp C ATTENTION Make sure to install the washer M20 E between the rotating flange and the swivel ring to avoid damage B A C D F E B A C D F E Fig 4 7 Arm on mobile unit For...

Страница 9: ...ith a handle for easy positioning and a valve to regulate or shut off the airflow All movement of the arm is controlled from the hood Fig 5 1 A Sealed shut off valve H D types only B Control valve C H...

Страница 10: ...al arm movement If necessary adjust the friction refer to section 6 2 X 6 2 Arm adjustment If the extraction arm or a part of it does not stay in the desired position you must adjust the friction Fig...

Страница 11: ...ppendix I regarding basic health and safety requirements in connection with the construction and manufacturing of machinery Applicable standards EN ISO 12100 2010 Safety of machinery Basic concepts ge...

Страница 12: ...rane 1 Start with par 4 4 1 par 4 4 2 INS_FlexMax 2 Arm mounting par 4 4 3 par 4 4 3 par 4 4 3 3 Fan mounting par 4 4 4 par 4 4 4 4 Hood mounting par 4 6 par 4 6 par 4 6 KUA 160 H ATEX Wall Stanchion...

Страница 13: ...e anchor bolts A A A A mounting plate A mounting plate A mounting plate A DESCRIPTION REV DRAWING NO 3RD ANGLE PROJECTION 0 MATERIAL DR The information contained in this drawing is the sole property o...

Страница 14: ...550 0000101906 0000101915 0000101904 0000101905 0000101913 0000101914 0000101908 0000101537 0000102989 0000101903 B C D C D A A B B 0000102396 0000102398 0000102400 0000102397 0000102399 0000102401 00...

Страница 15: ...160 4 KUA 160 2S 0000101904 Hose L 850 mm 163 mm incl 2 hose clamps 0000102387 Inner frame KUA 160 2S complete 0000102396 Inner tube KUA 160 2 0000102397 Outer tube KUA 160 2 KUA 160 3S 0000101905 Hos...

Страница 16: ...www plymovent com 0000101887 010920 B KUA 160...

Отзывы: