Plymovent KUA-160/2H Скачать руководство пользователя страница 5

0000101887/010920/B KUA-160 

4

perfect condition in accordance with its intended use and the 

instructions explained in the user manual.

Technical specifications

Do not change the specifications given in this manual. 

Modifications

Modification of (parts of) the product is not allowed.

Product combinations

If the product is used in combination with other products or 

machines, the safety instructions in the documentation of 

these products also apply.

Installation

 

- The installation of this product is exclusively reserved to 

authorised, trained and qualified engineers. 

 

- During installation, always use Personal Protective 

Equipment (PPE) to avoid injury. This also applies to persons 

who enter the work area during installation.

 

-

Use sufficient climbing gear and safety guards when working 

on a higher level than 2 metres (local restrictions may 

apply). 

 

- Do not install the product in front of entrances and exits 

which must be used for emergency services. 

 

- Mind any gas and water pipes and electric cables.

 

- Make sure that the workspace is well illuminated. 

 

- Stay alert and keep your attention to your work. Do not 

install the product when you are under the influence of 

drugs, alcohol or medicine. 

 

- Air containing particles such as chromium, nickel, beryllium, 

cadmium, lead etc., should never be recycled. This air must 

always be brought outside the working area.

Use

WARNING!

Fire hazard! Do 

not

 use the product for:

 

- polishing applications in combination with 

grinding, welding or any other application that 

generate sparks 

(fibers from polishing or abrasive flap disks 

are highly flammable and pose a high risk of filter fires when 

exposed to sparks)

 

- arc-air gouging

 

-

extracting flammable, glowing or burning particles 

or solids or liquids

 

- extracting of aggressive fumes (such as 

hydrochloric acid) or sharp particles

 

- sucking cigarettes, cigars, oiled tissues, and other 

burning particles, objects, and acids

WARNING!

Explosion hazard! Do 

not

 use the product for 

explosion-hazardous applications, e.g.:

 

- aluminium laser cutting

 

- grinding aluminium and magnesium

 

- explosive environments or explosive substances/

gases

This warning does not apply to KUA-160 ATEX arms

WARNING!

Do 

not

 use the product for:

 

-

extraction of hot gases (more than 70°C/158°F 

continuously)

 

-

flame spraying

 

- extraction of cement, saw dust, wood dust etc.

•  Inspect the product and check it for damage. Verify the 

functioning of the safety features. 

•  During use, always use Personal Protective Equipment 

(PPE) to avoid injury. This also applies for persons who 

enter the work area.

•  Check the working environment. Do not allow unauthorised 

persons to enter the working environment. 

•  Protect the product against water and humidity.
• 

Make sure the room is always sufficiently ventilated; this 

applies especially to confined spaces.

•  Make sure that the workshop, in the vicinity of the product, 

contains sufficient approved fire extinguishers (suitable for 

fire classes ABC). 

Service, maintenance and repairs

•  Obey the maintenance intervals given in this manual. 

Overdue maintenance can lead to high costs for repair and 

revisions and can render the guarantee null and void. 

•  Always use Personal Protective Equipment (PPE) to avoid 

injury. This also applies for persons who enter the work 

area.

• 

Make sure the room is sufficiently ventilated. 

•  Use tools, materials, lubricants and service techniques 

which have been approved by the manufacturer. Never use 

worn tools and do not leave any tools in or on the product. 

•  Safety features which have been removed for service, 

maintenance or repairs, must be put back immediately 

after finishing these jobs and it must be checked that they 

still function properly. 

• 

Use sufficient climbing gear and safety guards when 

working on a higher level than 2 metres (local restrictions 

may apply). 

•  Clean the area afterwards.

ATTENTION

Service, maintenance and repairs must be 

performed in accordance with directive TRGS 560 

and TRGS 528 by authorised, qualified and trained 

persons (skilled) using appropriate work practices.

Personal protective equipment (PPE)

Wear respiratory protection and protective 

gloves during service, maintenance and 

repairs.

INSTALLATION

4.1 

Tools and requirements

You need the following tools and requirements to 

install the product:

 

- basic tools

4.2 

To be sourced locally

You need the following material to install the 

product:

 

- wall mounting hardware

6

4.3 

Unpacking

Make sure that the product is complete. The 

package contains:

 

- extraction arm (pre-assembled)

 

-

rotating flange

 

- arm swivel ring, incl. rubber collar

 

- extraction hood

 

- hood collar with safety mesh

 

- washer M20

Additionally for “H” types:

 

-

wall bracket (with integrated rotating flange)

 

- hexagon bolt M6x25 (4)

If parts are missing or damaged, contact your supplier. 

6.  The type of hardware depends on the wall type

Содержание KUA-160/2H

Страница 1: ...www plymovent com Extraction arm A KUA 160 H S ATEX Installation and user manual EN...

Страница 2: ...lation use maintenance and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of the type given on the cover page T...

Страница 3: ...h The arm is fitted with a control valve and is 360 rotatable1 The hood is 90 movable in four directions The KUA 160 arm is available in four different types type H for hanging mounting wall bracket i...

Страница 4: ...always fully responsible for observing the local safety instructions and regulations Observe all applicable safety instructions and regulations User manual Everyone working on or with the product must...

Страница 5: ...cement saw dust wood dust etc Inspect the product and check it for damage Verify the functioning of the safety features During use always use Personal Protective Equipment PPE to avoid injury This als...

Страница 6: ...re depends on the wall type You can mount the wall bracket on e g A a thin brick or concrete wall min thickness 100 mm with four threaded rods M10 B a thick brick or concrete wall with four cotter bol...

Страница 7: ...bolts M6x25 washers M6 Fig 4 3 A B C D E F B D F G G Mounting of the arm For mounting of the hood refer to paragraph 4 6 In case of a KUA 160 H ATEX subsequently proceed with paragraph 4 7 4 4 4 Fan...

Страница 8: ...ivel ring D with the hose clamp C ATTENTION Make sure to install the washer M20 E between the rotating flange and the swivel ring to avoid damage B A C D F E B A C D F E Fig 4 7 Arm on mobile unit For...

Страница 9: ...ith a handle for easy positioning and a valve to regulate or shut off the airflow All movement of the arm is controlled from the hood Fig 5 1 A Sealed shut off valve H D types only B Control valve C H...

Страница 10: ...al arm movement If necessary adjust the friction refer to section 6 2 X 6 2 Arm adjustment If the extraction arm or a part of it does not stay in the desired position you must adjust the friction Fig...

Страница 11: ...ppendix I regarding basic health and safety requirements in connection with the construction and manufacturing of machinery Applicable standards EN ISO 12100 2010 Safety of machinery Basic concepts ge...

Страница 12: ...rane 1 Start with par 4 4 1 par 4 4 2 INS_FlexMax 2 Arm mounting par 4 4 3 par 4 4 3 par 4 4 3 3 Fan mounting par 4 4 4 par 4 4 4 4 Hood mounting par 4 6 par 4 6 par 4 6 KUA 160 H ATEX Wall Stanchion...

Страница 13: ...e anchor bolts A A A A mounting plate A mounting plate A mounting plate A DESCRIPTION REV DRAWING NO 3RD ANGLE PROJECTION 0 MATERIAL DR The information contained in this drawing is the sole property o...

Страница 14: ...550 0000101906 0000101915 0000101904 0000101905 0000101913 0000101914 0000101908 0000101537 0000102989 0000101903 B C D C D A A B B 0000102396 0000102398 0000102400 0000102397 0000102399 0000102401 00...

Страница 15: ...160 4 KUA 160 2S 0000101904 Hose L 850 mm 163 mm incl 2 hose clamps 0000102387 Inner frame KUA 160 2S complete 0000102396 Inner tube KUA 160 2 0000102397 Outer tube KUA 160 2 KUA 160 3S 0000101905 Hos...

Страница 16: ...www plymovent com 0000101887 010920 B KUA 160...

Отзывы: