0000110982/231018/A SER
EN - 5
been built in accordance with state-of-the-art standards and
recognized safety regulations. Only use this product when in
technical perfect condition in accordance with its intended use
and the instructions explained in the user manual.
Technical specifications
The specifications given in this manual must not be altered.
Modifications
Modification is not allowed.
Installation
- The installation of this product is exclusively reserved to
authorised, well-trained and qualified engineers.
- Inspect the product and check it for damage. Verify the
functioning of the safety features.
- Never install the product in front of entrances and exits
which must be used for emergency services.
- Make sure that the workshop, in the vicinity of the product,
contains sufficient approved fire extinguishers.
Please note that additional tools and machines may be needed
depending on the installation situation (installation height,
space available etc).
Use
- Check the working environment. Do not allow unauthorised
persons to enter the working environment.
- Protect the product against water and humidity.
- Use common sense. Stay alert and keep your attention to
your work. Do not use the product when you are under the
influence of drugs, alcohol or medicine.
-
Make sure the room is always sufficiently ventilated;
this applies especially to confined spaces.
Operating the system
- With SER, an operator pulls the hose down, which releases
the ratchet lock; the operator connects the nozzle and when
the hose is no longer needed, the operator pulls down on the
hose to release the ratchet lock and guides the hose back to
its rest position, which is determined by the hose stop-ring.
Service, maintenance and repairs
- This manual contains instructions for replacing the hose,
replacing the cassette and replacing bearings. Refer to the
Maintenance section in this manual for details.
WARNING!
Maintenance should only be performed by
authorised, qualified and trained persons (skilled)
using appropriate work practices.
4
INSTALLATION
4.1
Assembly
Tools:
These tools are needed to install SER:
- Power Drill/Electric Screw gun
- General hand tools/wrenches
- Screw drivers
Complete these steps to install the SER hose reel, as indicated
in
fig. 4.1a.
•
Set the tension on the exhaust reel according to the
Pre-tension table in this section. Turn the drum in the
direction of the arrow; see arrow on the sticker of spring
housing.
•
Dismantle drum lid A (not needed for SER-1050-200
version)
•
Mount MAS Kit.
•
Mount hose to the socket inside the drum using clamp (E).
•
Bend hose into a natural soft curve and fasten it using
clamp (B).
•
Re-mount the drum lid (A).
•
Mount the edge protection (C) at the opening of the drum
where the hose protrudes.
•
Mount the hose stop-ring (D) so that the hose stops at a
convenient height when it is reeled in.
•
The console holes are pre-set for the correct diameter
hose, as shown in
fig. 4.1b.
Fig. 4.1a Hose reel assembly
Note: For the SER-1050-200 version, the MAS kit is not
needed, as it uses a different hose mounting method for
the 200 mm (8 in.) hoses.
Fig. 4.1b Hose reel console holes
Ø 150 mm (6 in.)
Ø 125 mm (5 in.)
Ø 100 mm (4 in.)
Ø 75 mm (3 in.)