0000110982/231018/A SER 

EN - 5

been built in accordance with state-of-the-art standards and 

recognized safety regulations. Only use this product when in 

technical perfect condition in accordance with its intended use 

and the instructions explained in the user manual.

Technical specifications

The specifications given in this manual must not be altered.

Modifications

Modification is not allowed. 

Installation

 

- The installation of this product is exclusively reserved to 

authorised, well-trained and qualified engineers.

 

- Inspect the product and check it for damage. Verify the 

functioning of the safety features.

 

- Never install the product in front of entrances and exits 

which must be used for emergency services. 

 

- Make sure that the workshop, in the vicinity of the product, 

contains sufficient approved fire extinguishers.

Please note that additional tools and machines may be needed 

depending on the installation situation (installation height, 

space available etc). 

Use

 

- Check the working environment. Do not allow unauthorised 

persons to enter the working environment.

 

- Protect the product against water and humidity.

 

- Use common sense. Stay alert and keep your attention to 

your work. Do not use the product when you are under the 

influence of drugs, alcohol or medicine.

 

-

Make sure the room is always sufficiently ventilated;

 

this applies especially to confined spaces.

Operating the system

 

- With SER, an operator pulls the hose down, which releases 

the ratchet lock; the operator connects the nozzle and when 

the hose is no longer needed, the operator pulls down on the 

hose to release the ratchet lock and guides the hose back to 

its rest position, which is determined by the hose stop-ring.

Service, maintenance and repairs

 

- This manual contains instructions for replacing the hose, 

replacing the cassette and replacing bearings. Refer to the 

Maintenance section in this manual for details. 

 

WARNING!

Maintenance should only be performed by 

authorised, qualified and trained persons (skilled) 

using appropriate work practices.

 INSTALLATION

4.1 

Assembly

Tools:

These tools are needed to install SER:

 

- Power Drill/Electric Screw gun

 

- General hand tools/wrenches

 

- Screw drivers

Complete these steps to install the SER hose reel, as indicated 

in 

fig. 4.1a.

• 

Set the tension on the exhaust reel according to the 

Pre-tension table in this section. Turn the drum in the 

direction of the arrow; see arrow on the sticker of spring 

housing.

• 

Dismantle drum lid A (not needed for SER-1050-200 

version)

• 

Mount MAS Kit.

• 

Mount hose to the socket inside the drum using clamp (E).

• 

Bend hose into a natural soft curve and fasten it using 

clamp (B).

• 

Re-mount the drum lid (A).

• 

Mount the edge protection (C) at the opening of the drum 

where the hose protrudes.

• 

Mount the hose stop-ring (D) so that the hose stops at a 

convenient height when it is reeled in.

• 

The console holes are pre-set for the correct diameter 

hose, as shown in 

fig. 4.1b.

 

Fig. 4.1a   Hose reel assembly

Note:  For the SER-1050-200 version, the MAS kit is not 

needed, as it uses a different hose mounting method for 

the 200 mm (8 in.) hoses.

Fig. 4.1b   Hose reel console holes

Ø 150 mm (6 in.)

Ø 125 mm (5 in.)
Ø 100 mm (4 in.)

Ø 75 mm (3 in.)

Содержание ER-650-100

Страница 1: ...www plymovent com SER EN Spring Operated Exhaust Hose Reel...

Страница 2: ...s responsibility to ensure they have attained the most recent copy of this document for their files The instructions in this publication only serve as a guideline for installation use maintenance and...

Страница 3: ...SER EN 1 TABLE OF CONTENTS ENGLISH Page Preface 1 Introduction 3 2 Product description 4 3 Safety 5 4 Installation 6 5 Maintenance 10 6 Disposal 11 7 Pressure loss calculation 11 8 SER Spare parts 12...

Страница 4: ...or application of this equipment The examples and diagrams in this manual are included solely for illustrative purposes Because of the many variables and requirements associated with any particulate i...

Страница 5: ...springs that are factory installed to the outside of the reel assembly an operator pulls the hose down to a convenient position which locks the hose in place when no longer needed the operator recoils...

Страница 6: ...d must not be opened Be careful when servicing the SER product If you have any questions about the content in this manual please contact Plymovent or your Plymovent authorised distributor Be careful w...

Страница 7: ...perator connects the nozzle and when the hose is no longer needed the operator pulls down on the hose to release the ratchet lock and guides the hose back to its rest position which is determined by t...

Страница 8: ...made aware that a quarter turn of the hose should always remain on the drum as shown in fig 4 2 2a If the hose is pulled down completely the entire hose is removed from the drum and the recoil mechan...

Страница 9: ...7 in I 489 mm 19 2 in 489 mm 19 2 in 489 mm 19 2 in 489 mm 19 2 in 590 mm 23 2 in Hose length Mounting height Maximum reach 7 5 m 25 ft 3 m 9 8 ft 6 2 m 20 4 ft 3 5 m 11 5 ft 5 9 m 19 4 ft 4 m 13 1 ft...

Страница 10: ...racket Insert bolts and tighten slightly Slide the bracket up and down parallel to the A frame center to align with the hose reel outlet Tighten bolts to ensure the unit is properly secured C Unfold t...

Страница 11: ...om arm Mount spiro tubing and hose on the boom arm E Mount ducting bend to hose reel then mount the hose to the ducting bend F Readjust friction as needed G Fig 4 3 3a Mounting bracket for EB 3 5 EB 4...

Страница 12: ...equalise the spring tension if the spring still functions Unscrew all socket head cap screws at the spring casing C Mark the position of the spring casing Put the new spring casing in position Tighte...

Страница 13: ...I 150 mm 6 in 12 5 m 41 ft J 200 mm 8 in 10 m 33 ft Note 75 mm 3 in hoses are not available in North America A B C D E F G H I J Airflow Volume General Guidelines Vehicles serviced m3 h cfm Hose diam...

Страница 14: ...com click the Contact Plymovent link and then click Sales Offices CE Declaration CE declaration of conformity for machinery We Plymovent Koraalstraat 9 1812 RK Alkmaar the Netherlands herewith declar...

Страница 15: ...www plymovent com 0000110982 231018 A SER...

Отзывы: