background image

0000110982/231018/A SER 

EN - 2

GENERAL PRECAUTIONS

ATTENTION

Any fans or controls used with this hose reel may 

contain ESD (Electrostatic Discharge) sensitive parts 

and assemblies. Static control precautions may be 

required when installing, testing, servicing or 

repairing this assembly. Component damage can 

result if ESD control procedures are not followed.

IMPORTANT USER INFORMATION

Read this document in entirety before you install, configure, 

operate, or maintain this product. Plymovent systems are 

made code compliant. Users are required to familiarise 

themselves with installation in addition to requirements of all 

applicable codes, laws and standards.

Activities including installation, adjustments, putting into 

service, use, assembly, disassembly, and maintenance are 

required to be carried out by suitably trained personnel in 

accordance with applicable code of practice.

If this equipment is used in a manner not specified by the 

manufacturer, the protection provided by the equipment may 

be impaired. 

In no event will Plymovent be responsible or liable for indirect 

or consequential damages resulting from the use or application 

of this equipment.

The examples and diagrams in this manual are included solely 

for illustrative purposes. Because of the many variables and 

requirements associated with any particulate installation, 

Plymovent cannot assume responsibility or liability for actual 

use based on the examples and diagrams.

The operation of exhaust extraction systems can be affected 

by various factors including but not limited to proper design of 

the system, operating procedures, service and maintenance. 

Exhaust exposure levels should be checked after the system is 

installed and periodically thereafter to ensure that the air 

quality meets applicable regulations and exposure limit values.

SHOCK HAZARD

Labels may be on outside or inside of equipment as 

part of this exhaust removal system, such as fans or 

control boxes, to alert people that dangerous 

voltage may be present.

ARC FLASH HAZARD

Labels may be on outside or inside of the 

equipment, such as the control box, to alert people 

to potential Arc Flash. Arc Flash will cause severe 

injury or death. Wear proper Personal Protection 

Equipment (PPE). Follow ALL regulatory 

requirements for safe work practices and for 

Personal Protective Equipment (PPE).

BE SURE THAT ALL INSTALLATION, OPERATION, 

MAINTENANCE AND REPAIR PROCEDURES ARE 

PERFORMED ONLY BY QUALIFIED INDIVIDUALS.

Содержание ER-650-100

Страница 1: ...www plymovent com SER EN Spring Operated Exhaust Hose Reel...

Страница 2: ...s responsibility to ensure they have attained the most recent copy of this document for their files The instructions in this publication only serve as a guideline for installation use maintenance and...

Страница 3: ...SER EN 1 TABLE OF CONTENTS ENGLISH Page Preface 1 Introduction 3 2 Product description 4 3 Safety 5 4 Installation 6 5 Maintenance 10 6 Disposal 11 7 Pressure loss calculation 11 8 SER Spare parts 12...

Страница 4: ...or application of this equipment The examples and diagrams in this manual are included solely for illustrative purposes Because of the many variables and requirements associated with any particulate i...

Страница 5: ...springs that are factory installed to the outside of the reel assembly an operator pulls the hose down to a convenient position which locks the hose in place when no longer needed the operator recoils...

Страница 6: ...d must not be opened Be careful when servicing the SER product If you have any questions about the content in this manual please contact Plymovent or your Plymovent authorised distributor Be careful w...

Страница 7: ...perator connects the nozzle and when the hose is no longer needed the operator pulls down on the hose to release the ratchet lock and guides the hose back to its rest position which is determined by t...

Страница 8: ...made aware that a quarter turn of the hose should always remain on the drum as shown in fig 4 2 2a If the hose is pulled down completely the entire hose is removed from the drum and the recoil mechan...

Страница 9: ...7 in I 489 mm 19 2 in 489 mm 19 2 in 489 mm 19 2 in 489 mm 19 2 in 590 mm 23 2 in Hose length Mounting height Maximum reach 7 5 m 25 ft 3 m 9 8 ft 6 2 m 20 4 ft 3 5 m 11 5 ft 5 9 m 19 4 ft 4 m 13 1 ft...

Страница 10: ...racket Insert bolts and tighten slightly Slide the bracket up and down parallel to the A frame center to align with the hose reel outlet Tighten bolts to ensure the unit is properly secured C Unfold t...

Страница 11: ...om arm Mount spiro tubing and hose on the boom arm E Mount ducting bend to hose reel then mount the hose to the ducting bend F Readjust friction as needed G Fig 4 3 3a Mounting bracket for EB 3 5 EB 4...

Страница 12: ...equalise the spring tension if the spring still functions Unscrew all socket head cap screws at the spring casing C Mark the position of the spring casing Put the new spring casing in position Tighte...

Страница 13: ...I 150 mm 6 in 12 5 m 41 ft J 200 mm 8 in 10 m 33 ft Note 75 mm 3 in hoses are not available in North America A B C D E F G H I J Airflow Volume General Guidelines Vehicles serviced m3 h cfm Hose diam...

Страница 14: ...com click the Contact Plymovent link and then click Sales Offices CE Declaration CE declaration of conformity for machinery We Plymovent Koraalstraat 9 1812 RK Alkmaar the Netherlands herewith declar...

Страница 15: ...www plymovent com 0000110982 231018 A SER...

Отзывы: