Verify ignition key is in the ON position.
•
Make sure the code reader is correctly attached to vehicle
’
s
Data Link Connector (DLC).
•
Check DLC for cracked or recessed pins, or for any substance
that could prevent a good electrical connection.
•
Check EQP-103 OBDII connector for bent or broken pins.
•
Make sure the vehicle is OBDII/EOBD compliant.
•
Cycle the vehicle key to OFF for 10s and then back to ON.
•
Verify battery voltage is at least 8.0V with KOEO.
•
Verify that the control module is not defective.
7.2 Code Reader Does Not Power Up
If EQP-103 will not power up, communicate with vehicle
’
s control
module, or functions incorrectly in any other way, do the following:
•
Check DLC for broken or bent pins and clean the pins
if need be.
•
Make sure EQP-103 is correctly connected to vehicle
’
s DLC.
•
Verify battery voltage is at least 8.0V with KOEO.
7.3 Battery Replacement
EQP-103 needs a 9V cell battery to operate when disconnected
from the vehicle.
√√
When the icon appears, replace the battery as
instructed below.
To replace battery:
1.
Place the code reader face down.
2.
Remove battery cover with a screw driver.
3.
Remove battery and discard according to your local rules.
4.
Install a new 9V alkaline battery.
5.
Reinstall the battery cover with the screw driver.
Quality Products 12 Month Warranty Technical Support
Available from leading automotive specialists and retailers.
www.plusquip.com.au
EQP-103 User’s Manual
56