background image

ARKIWASH-PL018 User Manual Page 2 

ARKIWASH-PL018

 

Synopsis 

Thank  you  for  purchasing  the  ARKIWASH-PL018  by  Pluslite  Products.  Every  ARKIWASH-PL018  has  been 
thoroughly  tested  and  has  been  shipped  in  perfect  operating  condition.  Carefully  check  the  ship-  ping  carton  for 
damage  that  may  have  occurred  during  shipping.  If  the  carton  appears  to  be  damaged, 

carefully  inspect  your 

fixture for any damage and be sure all 

accessories  necessary  to  operate  the  unit  has  arrived  intact.  In  the  case 

damage  has  been  found  or  parts  are  missing,  please  contact  our  toll  free 

customer  support  number  for  further 

instructions. Do not return this unit to your dealer without first 

contacting customer support.

 

Introduction: 

The ARKIWASH-PL018 is a DMX intelligent, IP rated LED par fixture. 

This fixture can be used in a 

stand alone mode or connected in a Master/Slave configuration. 

This  par  has  multiple  operating  modes:  RGBW 

dimmer mode, Static Color mode, Auto Run mode, Color Macro mode, and DMX control. 

This product is intended to 

be used by professionally trained personnel only and is not suitable for private use.

 

These instructions contain important safety information regarding the use and maintenance of this unit. Please keep 
this manual with the unit, for future reference.

 

 

Caution! 

There are no user serviceable parts inside this unit. Do not attempt any repairs yourself, doing so will void 

your manufactures warranty. In the unlikely event your unit may require service please contact Più39. 

 

PLEASE recycle the shipping carton when ever possible. 

 

 

 

Multi Colors Dimmer

 

 

Multi Operating Modes

 

 

Linear Dimming 0-100%

 

 

DMX-512 protocol

 

 

IP65 Locking 3-Pin XLR Connections In/Out

 

 

Two DMX Modes: 4 Channel Mode, 6 Channel Mode, 8 Channel Mode,40 Channel Mode

 

 

Multiple Unit Power Linking

 

 

Included:

 

1 x IP65 Locking Power Cable

   

 

 

 

 

 

Содержание ARKIWASH-PL018

Страница 1: ...ARKIWASH PL018 User Manual Page 1 ARKIWASH PL018 Wall Washer LED IP65 User Instructions https www piu39av com pluslite lighting...

Страница 2: ...a stand alone mode or connected in a Master Slave configuration This par has multiple operating modes RGBW dimmer mode Static Color mode Auto Run mode Color Macro mode and DMX control This product is...

Страница 3: ...hile operating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times the unit s weight Also always use a safety cable that can hold...

Страница 4: ...nufacturer See page 24 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce h...

Страница 5: ...ction indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture is one which has been designed and tested to protect against the ingress of dust 6 and low pr...

Страница 6: ...PL018 Layout ARKIWASH PL018 User Manual Page 6 ARKIWASH PL018 back figure IP65 Locking Power Connection In Out IP65 Locking Singal 3P Connector In Out LCD Display FUNC button Up button Down button Ent...

Страница 7: ...t the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chai...

Страница 8: ...startsto listen to the digital control signal sent out from the DMX controller The assignment of this starting DMX address is achieved by setting the correct DMX address on the digital control display...

Страница 9: ...describe parameter CH1 Main Dimmer 0 255 CH2 R dimmer 0 100 0 255 CH3 G dimmer 0 100 0 255 CH4 B dimmer 0 100 0 255 CH5 W dimmer 0 100 0 255 CH6 Dimmer Mode Macro 1 Macro 2 Macro 3 Macro 16 0 15 16 3...

Страница 10: ...100 0 255 CH6 G dimmer 0 100 0 255 CH7 B dimmer 0 100 0 255 CH8 W dimmer 0 100 0 255 40CH describe parameter CH1 R1 dimmer 0 100 0 255 CH2 G1 dimmer 0 100 0 255 CH3 B1 dimmer 0 100 0 255 CH4 W1 dimme...

Страница 11: ...ature LCD Display describe parameter Mode DMX Addr 001 DMX Mode Master Slave Mode DMX Address Set 1 512 Mode CH 04CH DMX Mode Master Slave Mode DMX Channels Set 4 6 8 40 Mode Led Mode 01 Led Effect Mo...

Страница 12: ...rolling unit and the others will react to the controlling units built in programs Any unit can act as a Master or as a Slave however only one unit can be programmed to act as the Master Master Slave C...

Страница 13: ...IWASH PL018 Pixel Zone Control ARKIWASH PL018 User Manual Page 13 This fixture features pixel zone control See the diagram below which illustrates the specific pixel zone set up Pixel 1 Pixel 1 Pixel...

Страница 14: ...Chart DIMMER 100 50 10 0 0 Sec Dimming Mode Ramp Effect 0 sec Fade Time 1 sec Fade Time 255 0 255 0 Rise Time ms Down Time ms Rise Time ms Down Time ms Standard default 0 0 0 0 Stage 780 1100 1540 166...

Страница 15: ...ARKIWASH PL018 Dimensional Drawing ARKIWASH PL018 User Manual Page 15 NOT TO SCALE...

Страница 16: ...encounter with solutions Unit not responding to DMX 1 Check that the DMX cables are connected properly and are wired correctly pin 3 is hot on some other DMX devices pin 2 may be hot Also check that...

Страница 17: ...in 1 CREE LED s IP65 Any safe working position 400W 8 Fixtures Max 120V 15 FixturesMax 240V 12Kgs 466 x 123 x 338mm RGBW Color Mixing 4 DMX Modes 6 Channel Mode 8 DMX Modes 40 Channel Mode 2 Years ARK...

Отзывы: