background image

Dimmer Mode Chart

 

 

ARKIWASH-PL018 User Manual Page 14 

 

ARKIWASH-PL018

 

Dimmer Curve Chart

 

ARKIWASH-PL018

 

Dimmer Mode Chart

 

DIMMER 

            

100%

 

 

 

50%

 

 

10%

 

0% 

0 Sec

 

 

 

Dimming Mode 

Ramp Effect

 

0 sec Fade Time 

1 sec Fade Time 

255

 

 

 

0

 

255

 

 

 

0

 

 

Rise Time (ms) 

Down Time (ms) 

Rise Time (ms) 

Down Time (ms) 

Standard (default)

 

0

 

0

 

0

 

0

 

Stage

 

780

 

1100

 

1540

 

1660

 

TV

 

1180

 

1520

 

1860

 

1940

 

Architectural

 

1380

 

1730

 

2040

 

2120

 

Theatre

 

1580

 

1940

 

2230

 

2280

 

 

 

 

 

 

 

 

 

 

 

Time 
(ms)

 

Rise 
Time

 

Down 
Time

 

Содержание ARKIWASH-PL018

Страница 1: ...ARKIWASH PL018 User Manual Page 1 ARKIWASH PL018 Wall Washer LED IP65 User Instructions https www piu39av com pluslite lighting...

Страница 2: ...a stand alone mode or connected in a Master Slave configuration This par has multiple operating modes RGBW dimmer mode Static Color mode Auto Run mode Color Macro mode and DMX control This product is...

Страница 3: ...hile operating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times the unit s weight Also always use a safety cable that can hold...

Страница 4: ...nufacturer See page 24 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce h...

Страница 5: ...ction indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture is one which has been designed and tested to protect against the ingress of dust 6 and low pr...

Страница 6: ...PL018 Layout ARKIWASH PL018 User Manual Page 6 ARKIWASH PL018 back figure IP65 Locking Power Connection In Out IP65 Locking Singal 3P Connector In Out LCD Display FUNC button Up button Down button Ent...

Страница 7: ...t the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chai...

Страница 8: ...startsto listen to the digital control signal sent out from the DMX controller The assignment of this starting DMX address is achieved by setting the correct DMX address on the digital control display...

Страница 9: ...describe parameter CH1 Main Dimmer 0 255 CH2 R dimmer 0 100 0 255 CH3 G dimmer 0 100 0 255 CH4 B dimmer 0 100 0 255 CH5 W dimmer 0 100 0 255 CH6 Dimmer Mode Macro 1 Macro 2 Macro 3 Macro 16 0 15 16 3...

Страница 10: ...100 0 255 CH6 G dimmer 0 100 0 255 CH7 B dimmer 0 100 0 255 CH8 W dimmer 0 100 0 255 40CH describe parameter CH1 R1 dimmer 0 100 0 255 CH2 G1 dimmer 0 100 0 255 CH3 B1 dimmer 0 100 0 255 CH4 W1 dimme...

Страница 11: ...ature LCD Display describe parameter Mode DMX Addr 001 DMX Mode Master Slave Mode DMX Address Set 1 512 Mode CH 04CH DMX Mode Master Slave Mode DMX Channels Set 4 6 8 40 Mode Led Mode 01 Led Effect Mo...

Страница 12: ...rolling unit and the others will react to the controlling units built in programs Any unit can act as a Master or as a Slave however only one unit can be programmed to act as the Master Master Slave C...

Страница 13: ...IWASH PL018 Pixel Zone Control ARKIWASH PL018 User Manual Page 13 This fixture features pixel zone control See the diagram below which illustrates the specific pixel zone set up Pixel 1 Pixel 1 Pixel...

Страница 14: ...Chart DIMMER 100 50 10 0 0 Sec Dimming Mode Ramp Effect 0 sec Fade Time 1 sec Fade Time 255 0 255 0 Rise Time ms Down Time ms Rise Time ms Down Time ms Standard default 0 0 0 0 Stage 780 1100 1540 166...

Страница 15: ...ARKIWASH PL018 Dimensional Drawing ARKIWASH PL018 User Manual Page 15 NOT TO SCALE...

Страница 16: ...encounter with solutions Unit not responding to DMX 1 Check that the DMX cables are connected properly and are wired correctly pin 3 is hot on some other DMX devices pin 2 may be hot Also check that...

Страница 17: ...in 1 CREE LED s IP65 Any safe working position 400W 8 Fixtures Max 120V 15 FixturesMax 240V 12Kgs 466 x 123 x 338mm RGBW Color Mixing 4 DMX Modes 6 Channel Mode 8 DMX Modes 40 Channel Mode 2 Years ARK...