Re-imagine Beyond Technology
3)
10G/25G Switch Configuration Requirements
●
FEC must be disabled on all switch ports connected to the Plura monitor 2110 ports.
●
PTP must be enabled on the switch and on all switch ports connected to the Plura
monitor 2110 ports.
4)
2022-7 Hitless Switching Toggle ON
-
Configuring Flows for Redundancy
●
SMPTE 2022-7 redundancy is enabled when the 2022-7 Hitless Switching toggle is set
to the ON position. This will enable use of the secondary flow configurations. Each
channel (Main/Aux) has its own independent hitless toggle switch.
●
The primary interface media flows (video/audio/ancillary) are always the main flows in
a
redundant pair upon start-up (enabling) of decapsulation when using 2022-7.
●
The secondary interface media flows (video/audio/ancillary) are only ever used for
2022-7 hitless switching mode and cannot be used by themselves independently of
the
primary
media flows.
●
Conflicting destination IP addresses. All flows on all tabs must have unique destination
IP addresses. Flows cannot share the same destination IP address as another flow. This
is also true between primary and secondary and between the Main and Aux channel
tabs. It does not matter if the flows are enabled or not, conflicts are not allowed.
●
You must have PTP enabled in your Media LAN switch for 2022-7 to function properly.
●
All flows must be synchronized and aligned (RTP sequence numbers) at encapsulation
for 2022-7hitless switching to function properly at the decap.
●
The video flows for the primary and secondary must have the same video format. The
content doesn’t necessarily have to be identical but it usually is.
●
A proper 2022-7 hitless switching configuration for a flow involves setting valid config
values for both the primary and secondary for that flow. You must also enable both the
primary and secondary for the flow. For example, to set up 2022-7 for the video flow on
the Main channel (to monitor), you’d need to configure the primary video flow and
secondary video flow on the Main tab and enable them both. The same goes for audio
and ancillary.
5)
2022-7 Hitless Switching Toggle OFF
-
Clean Switch Mode
●
Clean Switch mode is enabled when the 2022-7 Hitless Switching toggle is set to the
OFF position. Each channel (Main/Aux) has its own independent hitless toggle switch.
●
All secondary flows are disabled for Clean Switch mode (no redundancy).
●
Conflicting
destination IP addresses. All flows on all tabs must have unique destination
IP addresses. Flows cannot share the same destination IP address as another flow. This
is also true between primary and secondary and between the Main and Aux channel
tabs. It
does not matter if the flows are enabled or not, conflicts are not allowed.
●
To perform a clean switch, update the config values for each flow and hit submit.
The new config values will be applied and a clean switch will occur to the new flow
configurations.
●
Note that it may take several seconds after submitting for the switch to occur.
Operating Instructions21
SFP-H-7 SERIES with PIPM-R-7-TypeC
21