background image

Re-imagine Beyond Technology

[email protected]

3)

10G/25G Switch Configuration Requirements

FEC must be disabled on all switch ports connected to the Plura monitor 2110 ports.

PTP must be enabled on the switch and on all switch ports connected to the Plura

monitor 2110 ports.

4)

2022-7 Hitless Switching Toggle ON

 

-

 

Configuring Flows for Redundancy

SMPTE 2022-7 redundancy is enabled when the 2022-7 Hitless Switching toggle is set
to the ON position. This will enable use of the secondary flow configurations. Each

channel (Main/Aux) has its own independent hitless toggle switch.

The primary interface media flows (video/audio/ancillary) are always the main flows in

 

a

redundant pair upon start-up (enabling) of decapsulation when using 2022-7.

The secondary interface media flows (video/audio/ancillary) are only ever used for
2022-7 hitless switching mode and cannot be used by themselves independently of

 

the

primary

 

media flows.

Conflicting destination IP addresses. All flows on all tabs must have unique destination
IP addresses. Flows cannot share the same destination IP address as another flow. This
is also true between primary and secondary and between the Main and Aux channel

tabs. It does not matter if the flows are enabled or not, conflicts are not allowed.

You must have PTP enabled in your Media LAN switch for 2022-7 to function properly.

All flows must be synchronized and aligned (RTP sequence numbers) at encapsulation

for 2022-7hitless switching to function properly at the decap.

The video flows for the primary and secondary must have the same video format. The

content doesn’t necessarily have to be identical but it usually is.

A proper 2022-7 hitless switching configuration for a flow involves setting valid config

values for both the primary and secondary for that flow. You must also enable both the

primary and secondary for the flow. For example, to set up 2022-7 for the video flow on

the Main channel (to monitor), you’d need to configure the primary video flow and

secondary video flow on the Main tab and enable them both. The same goes for audio

and ancillary.

5)

2022-7 Hitless Switching Toggle OFF

 

-

 

Clean Switch Mode

Clean Switch mode is enabled when the 2022-7 Hitless Switching toggle is set to the

OFF position. Each channel (Main/Aux) has its own independent hitless toggle switch.

All secondary flows are disabled for Clean Switch mode (no redundancy).

Conflicting

 

destination IP addresses. All flows on all tabs must have unique destination

IP addresses. Flows cannot share the same destination IP address as another flow. This
is also true between primary and secondary and between the Main and Aux channel
tabs. It

 

does not matter if the flows are enabled or not, conflicts are not allowed.

To perform a clean switch, update the config values for each flow and hit submit.
The new config values will be applied and a clean switch will occur to the new flow

configurations.

Note that it may take several seconds after submitting for the switch to occur.

Operating Instructions21

SFP-H-7 SERIES with PIPM-R-7-TypeC

21

Содержание PIPM-R-7-Type C

Страница 1: ...rainc com Operating Instructions PIPM R 7 Type C Plura IP Module for SFP H 7 Series SFP 317 H 7 SFP 321 H 7 SFP 324 H 7 SFP 332 H 7 SFP 347 H 7 SFP 355 H 7 SFP 324 H 7 SFP Modules Operating Instructio...

Страница 2: ...O THE CONTROL LAN USER INTERFACE UI 5 WEB CONFIGURATION INTERFACE 1 OVERVIEW 2 EMBER CONTROL UPDATE 3 MONITOR FPGA AND FIRMWARE 4 EMBER TSL LICENSE UPDATE 5 WEB UI UPDATE 6 MEDIA LAN 2110 CONTROL OUT...

Страница 3: ...or repair or work by third parties Important safeguards for you and your new product Your product has been manufactured and tested with your safety in mind However improper use can result in potential...

Страница 4: ...ning storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet This will prevent possible damage to the product due to lightning and power line surges 14 G...

Страница 5: ...etermine that the product is in proper operating condition and the warranty seal is provided 18 Mounting The product should be mounted on a wall as recommended in the instructions 19 Power This set op...

Страница 6: ...th optional license Ember NMOS JT NM Interoperability support Management Interface support NMOS REST API In band Web UI Ember Out band control support NMOS IS 04 discovery and registration NMOS IS 05...

Страница 7: ...P 3 IP Stream 3G Plura SFP H 7 monitors are equipped with two generic compatible 10G SR SFP 850nm digital optical monitoring LC MMF optical transceiver modules Dual 10GbE De Encapsulation channels are...

Страница 8: ...2 SDI AUX MAIN SUB SFP Modules Output CH selected ALL SFP Modules ALL Output CH selected FUNCTION F1 F2 F3 Executes functions of user selected UNDEF Aspect Mono Blue only Audio Channel Safety area mar...

Страница 9: ...onnectivity PIPM R 7 I O Description Ethernet Port Control LAN out band Dual SFP GigE Ports 2x 10 GigE SFP cages for media LAN SDI AUX O P 1EA Serial Digital 3Gb s 1 485Gb s 270Mb s BNC Jack Table 2 S...

Страница 10: ...UI Follow the instructions below to access this interface Chrome and Firefox browsers are recommended for control on Windows 2 Connecting to the Control LAN User Interface UI Plug in the Ethernet cabl...

Страница 11: ...the Control LAN IP address in the browser address line If this connects properly please contact Plura Support to get and install the latest web update From the Control LAN UI landing page the Monitor...

Страница 12: ...te the monitor and the IP 2110 module through its web interface 2 Ember Control Update Download the Ember Update software to your computer Open the Control LAN UI Monitor Update page Refer to section...

Страница 13: ...ploaded the browser will go to a white page with a Reboot button Click the reboot button then wait approximately 30 to 40 seconds before trying to reconnect to the Control LAN UI The Ember Control Upd...

Страница 14: ...te box Select your FPGA File Navigate to the folder with the FPGA and select all Click on the Upload button Figure 12 FPGA File Update Once the file is uploaded the browser will go to a white screen w...

Страница 15: ...seconds to a minute the screen will go black and the standby light may flash to show that the unit is updating Wait until the unit resets itself this may take a few minutes On your Plura monitor press...

Страница 16: ...top right corner of the page shown in Figure 9 below Download the Ember TSL License Update file to your computer Open the Control LAN UI Monitor Update page Refer to section Connecting to the Control...

Страница 17: ...te is now complete 5 Web UI Update Download the Web Update file to your computer Open the Control LAN UI Monitor Update page Refer to section Connecting to the Control LAN UI Figure 17 Plura UI Click...

Страница 18: ...igure 19 Upload the Web UI Update File Once the file is uploaded the browser will go to a white screen with a reboot button Click reboot The web UI is now upgraded to the latest version To check the v...

Страница 19: ...ol Main and Management Figure 21 below shows the UI Main Tab In the Main tab there are fields to set the Video Audio and the Ancillary flows configuration Each flow allows configuration of both its Pr...

Страница 20: ...gement Tab The management tab also provides the primary and secondary transceiver information Figures 23 24 below Figure 23 Primary Transceiver Information Figure 24 Secondary Transceiver Information...

Страница 21: ...capsulation for 2022 7hitless switching to function properly at the decap The video flows for the primary and secondary must have the same video format The content doesn t necessarily have to be ident...

Страница 22: ...econd ary if enabled flows This is done using the Populate From SDP button at the top of each channels tab just under the 2022 7 Hitless Switching toggle figure 25 Figure 25 Main Populate From SDP But...

Страница 23: ...logy sales plurainc com Figure 26 Import SDP URL Enter valid SDP URLs for each desired flow and click the populate button figure 27 Figure 27 Example of SDP URLs Operating Instructions23 SFP H 7 SERIE...

Страница 24: ...ress and port set to 0 s with the flow disabled These flows can be edited manually before submitting 7 Specific Configuring Using REST URLs via REST API Client Some configurations and status are curre...

Страница 25: ...15 9625 Sales plurainc com Plura Asia Ph 82 10 6688 8826 Sales plurainc com Corporate Offices Plura Broadcast Inc Ph 1 602 944 1044 Sales plurainc com U S A GERMANY U A E S KOREA Re imagine Beyond Tec...

Отзывы: