PX-R820T OPERATION MANUAL
45
If the SCSI device driver cannot be loaded properly, either a software or
hardware conflict exists. Software conflicts are generally caused by memory
managers; hardware conflicts by two peripherals vying for the same address
space. Please read the next two sections on Software and Hardware conflicts.
Software Conflict with Other Device Drivers
The SCSI interface board normally designates the device driver as the first
device driver loaded by the computer. When the computer has a memory
manager (e.g., HIMEM.SYS, 386MAX.SYS, or QEMM.SYS), in most cases the
memory manager is loaded first and the device driver loaded directly
thereafter.
If other device drivers are loading before the CD-ROM driver, place them after
the CD-ROM driver. If the memory manager tries to load the device driver into
high memory (e.g., DEVICEHIGH or LOADHIGH), disable the function so that
the driver is loaded into conventional memory.
Hardware Conflict Between the Interface Board and Your Computer
The SCSI interface board may be in conflict with another peripheral in your
computer. Normally, this conflict can be settled by selecting a different address
for the SCSI interface board. In some cases, you may wish to select a different
address for the conflicting peripheral.
If the driver still does not recognize the interface board, try the following:
1) Remove all non-essential peripherals from your computer (e.g.,
network boards, fax boards, etc.) and their device drivers from the
CONFIG.SYS and AUTOEXEC.BAT files.
2) Reboot the computer and ensure that the SCSI card’s ASPI and
device driver recognizes the CD-R drive.
3) Turn OFF the computer and reinstall each peripheral and its device
drivers one at a time.
4) Repeat Steps 2 and 3 until the problem reoccurs. This means that the
problem is with the last peripheral you installed.
Improper MSCDEX Installation
The Microsoft CD-ROM extensions (filename: MSCDEX.EXE) or equivalent
files are required to run your CD-R drive under MS-DOS. If the SCSI driver was
successfully loaded, check for proper installation of MSCDEX.EXE by
rebooting the computer and watching the AUTOEXEC.BAT file as it executes
for an error message.
CHAPTER 12 — Troubleshooting