![Playworld Systems Cozy Cocoon Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/playworld-systems/cozy-cocoon/cozy-cocoon_installation-instructions-manual_1567380009.webp)
Guidelines & Information (fs RPE)
Annex Page 1 of 6
Guidelines
Important ! Please Read Completely Before Beginning Installation.
According
to a report published by the U. S. Consumer Product Safety Commission (C.P.S.C.)
72% of all playground injuries result from accidental falls. With this in mind, this
equipment is designed to fi ll the need for safe yet challenging play. In conjunction
with design efforts to reduce the possibilities of injuries, this equipment
must
be installed "Step by Step" per our installation instructions. As a new owner you
are responsible for the correct installation, safe use, and maintenance of your
equipment.
Installation Guidelines
•
Identify all parts and thoroughly read the assembly instructions before
beginning construction.
•
Refer to your playground equipment plan and footing diagram to assure
the equipment purchased
will fi t into your selected site area. The use and no-
encroachment zones around the play equipment shall be obstacle-free areas
designated for unrestricted circulation.
•
ASTM compliance:
For rotating play equipment that rotates around a vertical
axis with a maximum dimension
greater
than 20 inches (508 mm) measured
from the axis of rotation to the outermost perimiter which exceed the speed
limitation requirements shall not be less than 108 inches (2743 mm) on all sides.
This includes a use zone of 72 inches (1829 mm) that shall
not overlap
the use
zone of other structures. The exemption is equipment where the diameter of the
platform is less than 20 in. (510 mm) may overlap if the adjacent designated play
surfaces of each structure are less than 30 in. (760 mm) above the protective
surface. If adjacent designated play surfaces on either structure exceed a height
of 30 inches (760 mm), the minimum distance between structures shall be 108
inches (2743 mm).
•
For rotating play equipment that rotates around a vertical axis with a maximum
dimension
less than or equal
to 20 inches (508 mm) measured from the axis of
rotation to the outermost perimeter shall not be less than 72 inches (1829 mm)
on all sides. Overlapping use zones is allowable if the adjacent fall height of
each structure is less than or equal to 30 inches (760 mm) above the protective
surfacing. If adjacent play structures have a fall height greater than 30 inches
(760 mm) than the distance between the structures shall be no less than 108 in.
(2743 mm).
•
CSA compliance:
For rotating play equipment, the use zone should extend on
all sides a minimum distance of 1800 mm. This use zone may
not
be overlapped
by the use zones of adjacent play equipment. A no-encroachment zone is also
required for play equipment over 500 mm in diameter that rotates around a vertical
axis. In addition to the use zone measurement, this zone will extend an additional
1800 mm and may
not
be overlapped by the use or no-encroachment zones of
adjacent play equipment.
•
EN compliance:
For rotating play equipment, the use zone should extend on
all sides a minimum distance of 2000 mm. This use zone may
not
be overlapped
by the use zones of adjacent play equipment. There must also be a head clearance
of 2000 mm above the maximum height of the rotating play equipment. Refer to
the Use Zone diagram or master structure drawing.
•
Site layout is a critical part of the overall installation. Footings must be
measured and marked accurately according to the footing diagram. A level and
clear installation site is ideal.
•
Good drainage around the structure and its supports is important. Inquire with
local contractors for appropriate recommendations.
•
After laying out all footings and before digging holes, be sure to inquire about
underground utilities that may exist.
•
Do not leave the job site unattended without making sure that all fastening
hardware on all components are tightened according to tightening torque
specifi cations listed on every installation guide. We also recommend roping off
construction area and covering all holes that do not contain a piece of equipment
with plywood or other suitable material.
•
Excavate holes as shown in the footing detail. If a level and clear site cannot
be obtained, adjust the depth of footing to maintain a level footing base. If soil
conditions are loose or unstable, a larger diameter footing may be required. Inquire
with local contractors for appropriate recommendations. Be sure concrete that
might have splashed onto the unit is washed off before it dries. Allow concrete to
harden 72 hours before allowing your structure to be used.
Assemble the entire
structure before pouring concrete unless specifi cally instructed to do so in
the installation instructions.