21
Note:
The valid NVP value range is 20 to 99.9. If you achieve an NVP
value that’s out of this range, the following occurs:
▪
The “Error” message blinks at the bottom of the LCD display
screen (see Figure 7).
▪
The unit recalls the last calculated NVP value.
▪
The Snap Shot™ exits Calibration Mode and enters
Test Mode.
▪
The last cable result displays at the top of the screen.
Figure 6.
Calculated NVP Value
Figure 7.
Error Message in Calibration Mode
7. Interpret display results and trouble-shoot potential cable faults (Open
and Short).