Information and warning alerts

 

Lp. 

Control Panel 

Indicators 

SOUND 

SIGNALS 

event 

procedure 

co

n

st

an

in

te

rm

it

te

n

t

 

 

 

 

If the fire is not visible - NO 
POWER. 

Make sure the device is properly connected to the power 
supply. 

If you see a fire - the device is 
in operation. 

Do not leave the device unattended by an adult. 

 

 

 

The device is ready for 
operation. 

You can run the device in accordance with section B.3 

 

 

 

No fuel in the tank 

Fill the fuel in accordance with B.2 paragraph 

 

 

 

Initial start-up of the device 

 

Wait for the appearance of fire, the light goes off. 

 

 

 

 
Works protected against too 
rapid restart of the hot device 
or the allowable temperature 
has been exceeded 
 

Allow the  device to cool down. After cooling the  device, 
the red indicator will turn off and the green indicator will 
start to flash. 

 

 

 

The device automatically 
turns off due to lack of fuel in 
the tank. 

Allow the device to cool down. After cooling the device, 
the red indicator will turn off 

 

 

× 

The fuel tank is full. 

It is not allowed to pour any more fuel! Close the Fanola 
filler bolt. The blue indicator will turn off, the green one 
will start to flash. 

 

×

 

 

There was a fuel spill or  

Immediately stop pouring the fuel. Remove the funnel, 
dry a visible moisture. Press the START / STOP button to 
turn off the sound.

 If the spillage is excessive the source 

of power needs to be disconnected. 

With the use of the 

manual pump, supplied by the manufacturer, pump out 
at least 1 litre of fuel from the fuel filler. Wait at least 1 
hour to evaporate the remaining moisture and then close 
the fuel filler bolt. Hold the ECO button for about 5 
seconds. If the alarm message reappears, wait a little bit 
longer until the rest of the moisture evaporates. If the 
message reappears, contact your service provider. 

the acceptable device 
operation temperature has 
been exceeded. 

If the alarm message appears during the start of the 
device, press the START / STOP button to turn off the 
sound and hold the ECO  button for about 5 seconds. 
If the message reappears, contact your service provider. 

 

× 

 

Operation error 

Press the START / STOP button to turn off the sound and 
hold the ECO button for about 5 seconds. 
If the message reappears, contact your service provider. 

10 

 

×

 

 

The device temperature 
below 10°C or critical 
operation error 

Press the START / STOP button to turn off the sound. 
Provide higher ambient temperature. Wait until the 
device obtains the indoor temperature. Hold down the 
ECO button for about 5 seconds. 
If the message reappears, contact your service provider. 

11 

READY

FUEL

HOT

 

× 

 

Filler bolt protection error. 

Shut the filler bolt. Press the START / STOP button to turn 
off the sound and hold the ECO button for about 5 
seconds. If the message reappears, contact your service 
provider. 

READY

FUEL

HOT

READY

FUEL

HOT

READY

FUEL

HOT

READY

FUEL

HOT

READY

FUEL

HOT

READY

FUEL

HOT

READY

FUEL

HOT

READY

FUEL

HOT

READY

FUEL

HOT

READY

FUEL

HOT

Содержание PrimeFire 2

Страница 1: ...USER S MANUAL PrimeFire 2 PF 0757 0000 000 Manufactured by Planika Sp z o o ul Bydgoska 38 86 061 Brzoza Poland Edition i0825 03 as of 18 03 2015 ...

Страница 2: ...IS S I IN NS ST TR RU UC CT TI IO ON N M MA AN NU UA AL L TABLE OF CONTENTS I General information 3 II Fuel 3 III Safety 3 IV Operation Operating elements 5 Initial start up of the device 5 Flame size regulation 7 Device extinguishing 7 Subsequent start up 7 Information and warning alert 7 V Cleaning and maintenance 9 VI Disposal and recycling 9 ...

Страница 3: ...ps regarding operation S 2 keep away from children S 7 the fuel tank should be tightly shut S 16 do not store in vicinity of sources of ignition do not burn S 46 in the event of ingestion consult a doctor and provide the packaging or label This mark stands for information which one needs to acquaint with This mark stands for warnings which one needs to acquaint with III Safety The PrimeFire produc...

Страница 4: ... and cool down the elements before moving the device The device should not be left without adult supervision Prevent handling of the device by persons not trained Do not attempt to make changes or repairs to the construction of the device on your own Repairs can be made only by a person trained to service the device Do not pour FANOLA liquid to a furnace as it may cause damage of the device and ca...

Страница 5: ... according to the instructions and the manual A Operating elements Control Panel v START STOP READY FUEL Planika HOT ERROR N E W S E N S O F F I R E PAT PEND ECO B Initial start up of the device 1 On the control panel the blue light flashes it indicates the lack of fuel in the tank Please refuel 2 Refueling 2 1 Open the Fanola filler bolt Service USB input hidden under a cap Starts the device from...

Страница 6: ...cturer 2 4 Pour the fuel to the point where the blue indicator blinks and the intermittent beep will sound Stop pouring Remove the funnel 2 5 Close the Fanola filler bolt The green indicator will flash on the control panel 3 Starting the device The green indicator flashes on the control panel 3 1 Press the START STOP button on the control panel and hold for 2 seconds You will hear a single beep 3 ...

Страница 7: ...ge will disappear and depending on the amount of the fuel in the tank either the green indicator will flash and indicate the readiness for operation or the blue indicator will indicate the lack of the fuel E Subsequent start up If on the control panel flashes the blue FUEL indicator start to run the product from the point B 2 If on the control panel flashes the green READY indicator you can start ...

Страница 8: ...e of power needs to be disconnected With the use of the manual pump supplied by the manufacturer pump out at least 1 litre of fuel from the fuel filler Wait at least 1 hour to evaporate the remaining moisture and then close the fuel filler bolt Hold the ECO button for about 5 seconds If the alarm message reappears wait a little bit longer until the rest of the moisture evaporates If the message re...

Страница 9: ...ean the inside of the device by unauthorized persons The manufacturer does not foresee a situation where it will be necessary to clean elements not normally available The manufacturer is not liable for damage resulting from improper operation non manual self dismantling attempts to modify using other liquids than those recommended in point II Fuel VI Disposal and recycling The product is equipped ...

Отзывы: