background image

 

 

 

 

 

USER’S MANUAL 

 

PrimeFire#2 

PF-0757-0000-000 

 

 

 

 

 

Manufactured by: 

 

Planika Sp. z o.o. 

ul. Bydgoska 38 

86-061 Brzoza 

Poland 

 
 

Edition i0825#03 as of 18.03.2015 

Содержание PrimeFire 2

Страница 1: ...USER S MANUAL PrimeFire 2 PF 0757 0000 000 Manufactured by Planika Sp z o o ul Bydgoska 38 86 061 Brzoza Poland Edition i0825 03 as of 18 03 2015 ...

Страница 2: ...IS S I IN NS ST TR RU UC CT TI IO ON N M MA AN NU UA AL L TABLE OF CONTENTS I General information 3 II Fuel 3 III Safety 3 IV Operation Operating elements 5 Initial start up of the device 5 Flame size regulation 7 Device extinguishing 7 Subsequent start up 7 Information and warning alert 7 V Cleaning and maintenance 9 VI Disposal and recycling 9 ...

Страница 3: ...ps regarding operation S 2 keep away from children S 7 the fuel tank should be tightly shut S 16 do not store in vicinity of sources of ignition do not burn S 46 in the event of ingestion consult a doctor and provide the packaging or label This mark stands for information which one needs to acquaint with This mark stands for warnings which one needs to acquaint with III Safety The PrimeFire produc...

Страница 4: ... and cool down the elements before moving the device The device should not be left without adult supervision Prevent handling of the device by persons not trained Do not attempt to make changes or repairs to the construction of the device on your own Repairs can be made only by a person trained to service the device Do not pour FANOLA liquid to a furnace as it may cause damage of the device and ca...

Страница 5: ... according to the instructions and the manual A Operating elements Control Panel v START STOP READY FUEL Planika HOT ERROR N E W S E N S O F F I R E PAT PEND ECO B Initial start up of the device 1 On the control panel the blue light flashes it indicates the lack of fuel in the tank Please refuel 2 Refueling 2 1 Open the Fanola filler bolt Service USB input hidden under a cap Starts the device from...

Страница 6: ...cturer 2 4 Pour the fuel to the point where the blue indicator blinks and the intermittent beep will sound Stop pouring Remove the funnel 2 5 Close the Fanola filler bolt The green indicator will flash on the control panel 3 Starting the device The green indicator flashes on the control panel 3 1 Press the START STOP button on the control panel and hold for 2 seconds You will hear a single beep 3 ...

Страница 7: ...ge will disappear and depending on the amount of the fuel in the tank either the green indicator will flash and indicate the readiness for operation or the blue indicator will indicate the lack of the fuel E Subsequent start up If on the control panel flashes the blue FUEL indicator start to run the product from the point B 2 If on the control panel flashes the green READY indicator you can start ...

Страница 8: ...e of power needs to be disconnected With the use of the manual pump supplied by the manufacturer pump out at least 1 litre of fuel from the fuel filler Wait at least 1 hour to evaporate the remaining moisture and then close the fuel filler bolt Hold the ECO button for about 5 seconds If the alarm message reappears wait a little bit longer until the rest of the moisture evaporates If the message re...

Страница 9: ...ean the inside of the device by unauthorized persons The manufacturer does not foresee a situation where it will be necessary to clean elements not normally available The manufacturer is not liable for damage resulting from improper operation non manual self dismantling attempts to modify using other liquids than those recommended in point II Fuel VI Disposal and recycling The product is equipped ...